Something wrong with this record ?
Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters
V Beckova, I Malatova
Language English Country Great Britain
NLK
Medline Complete (EBSCOhost)
from 1996-01-01 to 1 year ago
- MeSH
- Filtration MeSH
- Financing, Organized MeSH
- Mining MeSH
- Humans MeSH
- Radiation Monitoring instrumentation MeSH
- Radiation Protection standards instrumentation MeSH
- Radioactive Pollutants analysis MeSH
- Thorium analysis MeSH
- Uranium analysis MeSH
- Check Tag
- Humans MeSH
Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolni Rozinka' at Rozna, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.
- 000
- 02020naa 2200325 a 4500
- 001
- bmc11006812
- 003
- CZ-PrNML
- 005
- 20111210203338.0
- 008
- 110406s2008 xxk e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Bečková, Věra $7 xx0132612
- 245 10
- $a Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters / $c V Beckova, I Malatova
- 314 __
- $a National Radiation Protection Institute, Bartoskova 28, Prague 4, Czech Republic. vera.beckova@suro.cz
- 520 9_
- $a Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolni Rozinka' at Rozna, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.
- 650 _2
- $a filtrace $7 D005374
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hornictví $7 D008906
- 650 _2
- $a monitorování radiace $x přístrojové vybavení $7 D011834
- 650 _2
- $a radiační ochrana $x normy $x přístrojové vybavení $7 D011835
- 650 _2
- $a radioaktivní znečišťující látky $x analýza $7 D011848
- 650 _2
- $a thorium $x analýza $7 D013910
- 650 _2
- $a uran $x analýza $7 D014501
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Malátová, Irena $7 xx0153054
- 773 0_
- $t Radiation Protection Dosimetry $w MED00004029 $g Roč. 129, č. 4 (2008), s. 469-472 $x 0144-8420
- 910 __
- $a ABA008 $b x $y 7
- 990 __
- $a 20110412130904 $b ABA008
- 991 __
- $a 20110825105947 $b ABA008
- 999 __
- $a ok $b bmc $g 834429 $s 698931
- BAS __
- $a 3
- BMC __
- $a 2008 $b 129 $c 4 $d 469-472 $i 0144-8420 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a 2011-4B/ewme