• Something wrong with this record ?

Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters

V Beckova, I Malatova

. 2008 ; 129 (4) : 469-472.

Language English Country Great Britain

E-resources Online

NLK Medline Complete (EBSCOhost) from 1996-01-01 to 1 year ago

Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolni Rozinka' at Rozna, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.

000      
02020naa 2200325 a 4500
001      
bmc11006812
003      
CZ-PrNML
005      
20111210203338.0
008      
110406s2008 xxk e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Bečková, Věra $7 xx0132612
245    10
$a Dissolution behaviour of 238U, 234U and 230Th deposited on filters from personal dosemeters / $c V Beckova, I Malatova
314    __
$a National Radiation Protection Institute, Bartoskova 28, Prague 4, Czech Republic. vera.beckova@suro.cz
520    9_
$a Kinetics of dissolution of (238)U, (234)U and (230)Th dust deposited on filters from personal alpha dosemeters was studied by means of a 26-d in vitro dissolution test with a serum ultrafiltrate simulant. Dosemeters had been used by miners at the uranium mine 'Dolni Rozinka' at Rozna, Czech Republic. The sampling flow-rate as declared by the producer is 4 l h(-1) and the sampling period is typically 1 month. Studied filters contained 125 +/- 6 mBq (238)U in equilibrium with (234)U and (230)Th; no (232)Th series nuclides were found. Half-time of rapid dissolution of 1.4 d for (238)U and (234)U and slow dissolution half-times of 173 and 116 d were found for (238)U and (234)U, respectively. No detectable dissolution of (230)Th was found.
650    _2
$a filtrace $7 D005374
650    _2
$a lidé $7 D006801
650    _2
$a hornictví $7 D008906
650    _2
$a monitorování radiace $x přístrojové vybavení $7 D011834
650    _2
$a radiační ochrana $x normy $x přístrojové vybavení $7 D011835
650    _2
$a radioaktivní znečišťující látky $x analýza $7 D011848
650    _2
$a thorium $x analýza $7 D013910
650    _2
$a uran $x analýza $7 D014501
650    _2
$a financování organizované $7 D005381
700    1_
$a Malátová, Irena $7 xx0153054
773    0_
$t Radiation Protection Dosimetry $w MED00004029 $g Roč. 129, č. 4 (2008), s. 469-472 $x 0144-8420
910    __
$a ABA008 $b x $y 7
990    __
$a 20110412130904 $b ABA008
991    __
$a 20110825105947 $b ABA008
999    __
$a ok $b bmc $g 834429 $s 698931
BAS    __
$a 3
BMC    __
$a 2008 $b 129 $c 4 $d 469-472 $i 0144-8420 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a 2011-4B/ewme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...