-
Je něco špatně v tomto záznamu ?
Intraoperative reduction of the scapular body--a technical trick
J. Bartoníček, V. Frič, M. Tuček
Jazyk angličtina Země Spojené státy americké
- MeSH
- fraktury kostí chirurgie MeSH
- kostní destičky MeSH
- kostní dráty MeSH
- lidé středního věku MeSH
- lidé MeSH
- lopatka chirurgie zranění MeSH
- osteotomie metody MeSH
- vnitřní fixace fraktury metody přístrojové vybavení MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
When internal fixation of the scapular neck and body fractures is performed, a problem may occur with reduction and retention of position of the lateral border of the scapula during surgery. For this purpose, the authors have developed their own technique of stabilization using a K-wire in a novel way. The technique is indicated in a 2-part shear unstable fracture of the lateral border. It cannot be used in fractures with an intercalated segment. A 2.5-mm drill bit is used to drill a 1.5-cm deep hole into the "medullary cavity" of each of the 2 fragments of the lateral border. A K-wire, 1.5 mm in diameter and 2.5-cm long, is inserted into the distal fragment. The protruding end of the K-wire is inserted into the hole in the proximal fragment. This intramedullary peg helps to maintain reduction and keeps both fragments stable. Subsequently, the lateral border is stabilized with a 3.5-mm reconstruction plate. This technique is quite simple and allows for a temporary stabilization of fragments without compromising the subsequent fixation by plate screws.
Orthopaedic Department of 3rd Faculty of Medicine Charles University Prague Vinohrady Czech Republic
Citace poskytuje Crossref.org
- 000
- 02433naa 2200373 a 4500
- 001
- bmc11009502
- 003
- CZ-PrNML
- 005
- 20121113103848.0
- 008
- 110510s2009 xxu e eng||
- 009
- AR
- 024 __
- $a 10.1097/bot.0b013e31819f1dad $2 doi
- 035 __
- $a (PubMed)19318874
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Bartoníček, Jan, $d 1955- $7 nlk19990073000
- 245 10
- $a Intraoperative reduction of the scapular body--a technical trick / $c J. Bartoníček, V. Frič, M. Tuček
- 314 __
- $a Orthopaedic Department of 3rd Faculty of Medicine, Charles University, Prague-Vinohrady, Czech Republic. bartonicek.jan@seznam.cz
- 520 9_
- $a When internal fixation of the scapular neck and body fractures is performed, a problem may occur with reduction and retention of position of the lateral border of the scapula during surgery. For this purpose, the authors have developed their own technique of stabilization using a K-wire in a novel way. The technique is indicated in a 2-part shear unstable fracture of the lateral border. It cannot be used in fractures with an intercalated segment. A 2.5-mm drill bit is used to drill a 1.5-cm deep hole into the "medullary cavity" of each of the 2 fragments of the lateral border. A K-wire, 1.5 mm in diameter and 2.5-cm long, is inserted into the distal fragment. The protruding end of the K-wire is inserted into the hole in the proximal fragment. This intramedullary peg helps to maintain reduction and keeps both fragments stable. Subsequently, the lateral border is stabilized with a 3.5-mm reconstruction plate. This technique is quite simple and allows for a temporary stabilization of fragments without compromising the subsequent fixation by plate screws.
- 590 __
- $a bohemika - dle Pubmed
- 650 _2
- $a kostní destičky $7 D001860
- 650 _2
- $a kostní dráty $7 D001864
- 650 _2
- $a vnitřní fixace fraktury $x metody $x přístrojové vybavení $7 D005593
- 650 _2
- $a fraktury kostí $x chirurgie $7 D050723
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a osteotomie $x metody $7 D010027
- 650 _2
- $a lopatka $x chirurgie $x zranění $7 D012540
- 650 _2
- $a výsledek terapie $7 D016896
- 700 1_
- $a Frič, Vladimír $7 xx0105494
- 700 1_
- $a Tuček, Michal $7 xx0099649
- 773 0_
- $t Journal of Orthopaedic Trauma $w MED00002872 $g Roč. 23, č. 4 (2009), s. 294-298
- 910 __
- $a ABA008 $b x $y 2
- 990 __
- $a 20110513105750 $b ABA008
- 991 __
- $a 20121113103903 $b ABA008
- 999 __
- $a ok $b bmc $g 839052 $s 702889
- BAS __
- $a 3
- BMC __
- $a 2009 $b 23 $c 4 $d 294-298 $m Journal of orthopaedic trauma $n J Orthop Trauma $x MED00002872
- LZP __
- $a 2011-2B09/jvme