Optimized method for the determination of itopride in human plasma by high-performance liquid chromatography with fluorimetric detection

P. Ptáček, J. Klíma, J. Macek

. 2009 ; 877 (8-9) : 842-846.

Jazyk angličtina Země Nizozemsko

Perzistentní odkaz   https://www.medvik.cz/link/bmc11009554

A high-performance liquid chromatographic method with fluorescence detection for the determination of itopride in human plasma is reported. The sample preparation was based on liquid-liquid extraction of itopride from plasma with t-butylmethylether and dichloromethane (70:30, v/v) mixture followed by a back extraction of the analyte to the phosphate buffer (pH 3.2). Liquid chromatography was performed on an octadecylsilica column (55 mm x 4 mm, 3 microm particles), the mobile phase consisted of acetonitrile-triethylamine-15 mM dihydrogenpotassium phosphate (14.5:0.5:85, v/v/v), pH of the mobile phase was adjusted to 4.8. The run time was 3 min. The fluorimetric detector was operated at 250/342 nm (excitation/emission wavelength). Naratriptan was used as the internal standard. The limit of quantitation was 9.5 ng/ml using 0.5 ml of plasma. The method precision and inaccuracy were less than 8%. The assay was applied to the analysis of samples from a bioequivalence study.

000      
02534naa 2200373 a 4500
001      
bmc11009554
003      
CZ-PrNML
005      
20111210204231.0
008      
110510s2009 ne e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Ptáček, Pavel $7 xx0064070
245    10
$a Optimized method for the determination of itopride in human plasma by high-performance liquid chromatography with fluorimetric detection / $c P. Ptáček, J. Klíma, J. Macek
314    __
$a Pharmakl s.r.o., Seydlerova 2451, CZ-15800 Prague 13, Czech Republic.
520    9_
$a A high-performance liquid chromatographic method with fluorescence detection for the determination of itopride in human plasma is reported. The sample preparation was based on liquid-liquid extraction of itopride from plasma with t-butylmethylether and dichloromethane (70:30, v/v) mixture followed by a back extraction of the analyte to the phosphate buffer (pH 3.2). Liquid chromatography was performed on an octadecylsilica column (55 mm x 4 mm, 3 microm particles), the mobile phase consisted of acetonitrile-triethylamine-15 mM dihydrogenpotassium phosphate (14.5:0.5:85, v/v/v), pH of the mobile phase was adjusted to 4.8. The run time was 3 min. The fluorimetric detector was operated at 250/342 nm (excitation/emission wavelength). Naratriptan was used as the internal standard. The limit of quantitation was 9.5 ng/ml using 0.5 ml of plasma. The method precision and inaccuracy were less than 8%. The assay was applied to the analysis of samples from a bioequivalence study.
590    __
$a bohemika - dle Pubmed
650    _2
$a mladiství $7 D000293
650    _2
$a dospělí $7 D000328
650    _2
$a benzamidy $x krev $7 D001549
650    _2
$a benzylové sloučeniny $x krev $7 D001593
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $x přístrojové vybavení $7 D002851
650    _2
$a fluorometrie $x metody $x přístrojové vybavení $7 D005470
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a mladý dospělý $7 D055815
700    1_
$a Klíma, Josef $7 jx20050428026
700    1_
$a Macek, Jan $7 xx0061837
773    0_
$t Journal of Chromatography B: Analytical Technologies in the Biomedical & Life Sciences $w MED00006642 $g Roč. 877, č. 8-9 (2009), s. 842-846
910    __
$a ABA008 $b x $y 2
990    __
$a 20110513110120 $b ABA008
991    __
$a 20110905085458 $b ABA008
999    __
$a ok $b bmc $g 839087 $s 702942
BAS    __
$a 3
BMC    __
$a 2009 $b 877 $c 8-9 $d 842-846 $m Journal of chromatography. B, Analytical technologies in the biomedical and life sciences $n J Chromatogr B Analyt Technol Biomed Life Sci $x MED00006642
LZP    __
$a 2011-2B09/jvme

Najít záznam