-
Something wrong with this record ?
Daily prostate volume and position monitoring using implanted gold markers and on-board imaging during radiotherapy
Linda Kašaová, Igor Sirák, Jan Jansa, Petr Paluska, Jiří Petera
Language English Country Czech Republic
Document type Research Support, Non-U.S. Gov't
Digital library NLK
Full text - Article
Issue
Volume
Source
Source
NLK
Directory of Open Access Journals
from 1997
Free Medical Journals
from 1997
Open Access Digital Library
from 1997-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1997
- MeSH
- Humans MeSH
- Prostatic Neoplasms radiography radiotherapy MeSH
- Radiotherapy Planning, Computer-Assisted MeSH
- Tomography, X-Ray Computed MeSH
- Patient Positioning MeSH
- Prostate pathology radiography radiation effects MeSH
- Organ Size radiation effects MeSH
- Fiducial Markers MeSH
- Gold MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy.Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.
References provided by Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12000861
- 003
- CZ-PrNML
- 005
- 20120424122221.0
- 007
- ta
- 008
- 120117s2011 xr d f 000 0eng||
- 009
- eAR
- 024 7_
- $a 10.14712/18059694.2016.39 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Kašaová, Linda $7 xx0135627 $u Charles University in Prague, Faculty of Medicine and University Hospital, Department of Oncology and Radiotherapy, Hradec Králové; University of Defence, Faculty of Military Health Sciences, Hradec Králové
- 245 10
- $a Daily prostate volume and position monitoring using implanted gold markers and on-board imaging during radiotherapy / $c Linda Kašaová, Igor Sirák, Jan Jansa, Petr Paluska, Jiří Petera
- 504 __
- $a Literatura $b 16
- 520 9_
- $a Purpose: This study aimed to evaluate prostate volume changes and prostate motions during radiotherapy.Methods: In 2010, twenty-five patients were treated for prostate cancer by external beam radiotherapy with implanted fiducial markers. Coordinates of three gold markers on kilovoltage images were calculated daily. Volume changes in target structure were observed through changes in intermarker distances. Differences in patient position between laser-tattoo alignment and gold marker localization were evaluated. Intrafraction motion was assessed by measuring marker displacement on kilovoltage images acquired before and after fraction delivery. Results: Prostate shrinkage was observed in 60% of patients. The average shrinkage was 7% of the prostate’s initial volume. Corrections after laser-tattoo alignment remained mostly below 1 cm. The difference between marker centroid position on the actual images and the planning images was 2 ± 1 mm on average. The extension of intrafraction movements was 7.6 ± 0.2 mm on average. Conclusions: In our retrospective study, the possibility for prostate volume changes during radiotherapy was revealed. Intrafraction movements turned out to be the limiting factor in safety margin reduction.
- 650 02
- $a zaměřovací značky pro radioterapii $7 D057918
- 650 02
- $a zlato $7 D006046
- 650 02
- $a lidé $7 D006801
- 650 02
- $a mužské pohlaví $7 D008297
- 650 02
- $a velikost orgánu $x účinky záření $7 D009929
- 650 02
- $a polohování pacienta $7 D056888
- 650 02
- $a prostata $x patologie $x radiografie $x účinky záření $7 D011467
- 650 02
- $a nádory prostaty $x radiografie $x radioterapie $7 D011471
- 650 02
- $a plánování radioterapie pomocí počítače $7 D011880
- 650 02
- $a počítačová rentgenová tomografie $7 D014057
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Sirák, Igor $7 xx0135409 $u Charles University in Prague, Faculty of Medicine and University Hospital, Department of Oncology and Radiotherapy, Hradec Králové
- 700 1_
- $a Jansa, Jan $7 xx0103093 $u Charles University in Prague, Faculty of Medicine and University Hospital, Department of Oncology and Radiotherapy, Hradec Králové
- 700 1_
- $a Paluska, Petr $7 xx0135658 $u Charles University in Prague, Faculty of Medicine and University Hospital, Department of Oncology and Radiotherapy, Hradec Králové
- 700 1_
- $a Petera, Jiří, $d 1959- $7 xx0000229 $u Charles University in Prague, Faculty of Medicine and University Hospital, Department of Oncology and Radiotherapy, Hradec Králové
- 773 0_
- $t Acta medica (Hradec Králové) $x 1211-4286 $g Roč. 54, č. 4 (2011), s. 149-152 $w MED00010947
- 856 41
- $u https://actamedica.lfhk.cuni.cz/media/pdf/am_2011054040149.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 3077 $c 1072 $y 2
- 990 __
- $a 20120113150044 $b ABA008
- 991 __
- $a 20120424122157 $b ABA008
- 999 __
- $a ok $b bmc $g 893566 $s 757554
- BAS __
- $a 3 $a 4
- BMC __
- $a 2011 $b 54 $c 4 $d 149-152 $i 1211-4286 $m Acta Medica $n Acta Med. (Hradec Král.) $x MED00010947
- LZP __
- $a 2012-03/dkme