Je něco špatně v tomto záznamu ?
Paramagnetic antibody-modified microparticles coupled with voltammetry as a tool for isolation and detection of metallothionen as a bioindicator of metal pollution
L. Trnkova, I. Fabrik, D. Huska, H. Skutkova, M. Beklova, J. Hubalek, V. Adam, I. Provaznik, R. Kizek,
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
21863199
DOI
10.1039/c0em00306a
Knihovny.cz E-zdroje
- MeSH
- chemické látky znečišťující vodu toxicita MeSH
- magnetismus MeSH
- metalothionein chemie izolace a purifikace metabolismus MeSH
- monitorování životního prostředí metody MeSH
- živorodka metabolismus MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Low-molecular mass proteins rich in cysteines called metallothioneins (MT) can be considered as markers for the pollution of the environment by metals. Here, we report on suggestion for an automated procedure for the isolation of MT followed by voltammetric analysis. Primarily, we optimized the automated detection of MT using an electrochemical analyser. It was found that the most sensitive and repeatable analyses are obtained at a temperature of 4 °C for the supporting electrolyte. Further, we optimized experimental conditions for the isolation of MT by using antibody-linked paramagnetic microparticles. Under the optimal conditions (4 h long interaction between the microparticles and MT), the microparticles were tested on isolation of various amounts of MT. The lowest isolated amount of MT by antibody-linked paramagnetic microparticles was 5 μg ml(-1) of MT (50 ng). The automated procedure of MT isolation was further tested on isolation of MT from guppy fish (Poecilia reticulata) treated with silver(i) ions (50 μM AgNO(3)). The whole process lasted less than five hours and was fully automated. We attempted to correlate these results with the standard method for MT isolation. The correlation coefficient is 0.9901, which confirms that results are in good agreement. Moreover, the concentration of silver ions in tissues of fish treated with Ag(i) ions was determined by high performance liquid chromatography with electrochemical detection.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022377
- 003
- CZ-PrNML
- 005
- 20170410100657.0
- 007
- ta
- 008
- 120806s2011 xxk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1039/c0em00306a $2 doi
- 035 __
- $a (PubMed)21863199
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Trnkova, Libuse $u Department of Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, CZ-611 37, Brno, Czech Republic.
- 245 10
- $a Paramagnetic antibody-modified microparticles coupled with voltammetry as a tool for isolation and detection of metallothionen as a bioindicator of metal pollution / $c L. Trnkova, I. Fabrik, D. Huska, H. Skutkova, M. Beklova, J. Hubalek, V. Adam, I. Provaznik, R. Kizek,
- 520 9_
- $a Low-molecular mass proteins rich in cysteines called metallothioneins (MT) can be considered as markers for the pollution of the environment by metals. Here, we report on suggestion for an automated procedure for the isolation of MT followed by voltammetric analysis. Primarily, we optimized the automated detection of MT using an electrochemical analyser. It was found that the most sensitive and repeatable analyses are obtained at a temperature of 4 °C for the supporting electrolyte. Further, we optimized experimental conditions for the isolation of MT by using antibody-linked paramagnetic microparticles. Under the optimal conditions (4 h long interaction between the microparticles and MT), the microparticles were tested on isolation of various amounts of MT. The lowest isolated amount of MT by antibody-linked paramagnetic microparticles was 5 μg ml(-1) of MT (50 ng). The automated procedure of MT isolation was further tested on isolation of MT from guppy fish (Poecilia reticulata) treated with silver(i) ions (50 μM AgNO(3)). The whole process lasted less than five hours and was fully automated. We attempted to correlate these results with the standard method for MT isolation. The correlation coefficient is 0.9901, which confirms that results are in good agreement. Moreover, the concentration of silver ions in tissues of fish treated with Ag(i) ions was determined by high performance liquid chromatography with electrochemical detection.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a monitorování životního prostředí $x metody $7 D004784
- 650 _2
- $a magnetismus $7 D008280
- 650 _2
- $a metalothionein $x chemie $x izolace a purifikace $x metabolismus $7 D008668
- 650 _2
- $a živorodka $x metabolismus $7 D011036
- 650 _2
- $a chemické látky znečišťující vodu $x toxicita $7 D014874
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Fabrik, Ivo
- 700 1_
- $a Huska, Dalibor
- 700 1_
- $a Skutkova, Helena
- 700 1_
- $a Beklova, Miroslava
- 700 1_
- $a Hubalek, Jaromir
- 700 1_
- $a Adam, Vojtěch $7 xx0064599
- 700 1_
- $a Provaznik, Ivo
- 700 1_
- $a Kizek, Rene
- 773 0_
- $w MED00006489 $t Journal of environmental monitoring JEM $x 1464-0333 $g Roč. 13, č. 10 (2011), s. 2763-2769
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21863199 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20170410100955 $b ABA008
- 999 __
- $a ok $b bmc $g 944290 $s 779674
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 13 $c 10 $d 2763-2769 $e 20110824 $i 1464-0333 $m Journal of environmental monitoring $n J Environ Monit $x MED00006489
- LZP __
- $a Pubmed-20120806/12/01