-
Je něco špatně v tomto záznamu ?
Novel approaches to analysis of 3-chloropropane-1,2-diol esters in vegetable oils
E. Moravcova, L. Vaclavik, O. Lacina, V. Hrbek, K. Riddellova, J. Hajslova
Jazyk angličtina Země Německo
Typ dokumentu hodnotící studie, časopisecké články
NLK
ProQuest Central
od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2011-01-01 do Před 1 rokem
- MeSH
- estery analýza MeSH
- glycerol analogy a deriváty analýza MeSH
- hmotnostní spektrometrie metody MeSH
- oleje rostlin analýza MeSH
- vysokoúčinná kapalinová chromatografie metody MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
A sensitive and accurate method utilizing ultrahigh performance liquid chromatography (U-HPLC) coupled to high resolution mass spectrometry based on orbitrap technology (orbitrapMS) for the analysis of nine 3-chloropropane-1,2-diol (3-MCPD) diesters in vegetable oils was developed. To remove the interfering triacylglycerols that induce strong matrix effects, a clean-up step on silica gel column was used. The quantitative analysis was performed with the use of deuterium-labeled internal standards. The lowest calibration levels estimated for the respective analytes ranged from 2 to 5 μg kg(-1). Good recovery values (89-120%) and repeatability (RSD 5-9%) was obtained at spiking levels of 2 and 10 mg kg(-1). As an alternative, a novel ambient desorption ionization technique, direct analysis in real time (DART), hyphenated with orbitrapMS, was employed for no separation, high-throughput, semi-quantitative screening of 3-MCPD diesters in samples obtained by chromatographic fractionation. Additionally, the levels of 3-MCPD diesters measured in reallife vegetable oil samples (palm oil, sunflower oil, rapeseed oil) using both methods are reported. Relatively good agreement of the data generated by U-HPLC-orbitrapMS and DART-orbitrapMS were observed. With regard to a low ionization yield achieved for 3-MCPD monoesters, the methods presented in this paper were not yet applicable for the analysis of these contaminants at the naturally occurring levels.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12024074
- 003
- CZ-PrNML
- 005
- 20170410104025.0
- 007
- ta
- 008
- 120815s2012 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-012-5732-1 $2 doi
- 035 __
- $a (PubMed)22287050
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Moravcová, Eliška $u Department of Food Chemistry and Analysis, Institute of Chemical Technology, Prague, Czech Republic.
- 245 10
- $a Novel approaches to analysis of 3-chloropropane-1,2-diol esters in vegetable oils / $c E. Moravcova, L. Vaclavik, O. Lacina, V. Hrbek, K. Riddellova, J. Hajslova
- 520 9_
- $a A sensitive and accurate method utilizing ultrahigh performance liquid chromatography (U-HPLC) coupled to high resolution mass spectrometry based on orbitrap technology (orbitrapMS) for the analysis of nine 3-chloropropane-1,2-diol (3-MCPD) diesters in vegetable oils was developed. To remove the interfering triacylglycerols that induce strong matrix effects, a clean-up step on silica gel column was used. The quantitative analysis was performed with the use of deuterium-labeled internal standards. The lowest calibration levels estimated for the respective analytes ranged from 2 to 5 μg kg(-1). Good recovery values (89-120%) and repeatability (RSD 5-9%) was obtained at spiking levels of 2 and 10 mg kg(-1). As an alternative, a novel ambient desorption ionization technique, direct analysis in real time (DART), hyphenated with orbitrapMS, was employed for no separation, high-throughput, semi-quantitative screening of 3-MCPD diesters in samples obtained by chromatographic fractionation. Additionally, the levels of 3-MCPD diesters measured in reallife vegetable oil samples (palm oil, sunflower oil, rapeseed oil) using both methods are reported. Relatively good agreement of the data generated by U-HPLC-orbitrapMS and DART-orbitrapMS were observed. With regard to a low ionization yield achieved for 3-MCPD monoesters, the methods presented in this paper were not yet applicable for the analysis of these contaminants at the naturally occurring levels.
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $7 D002851
- 650 _2
- $a estery $x analýza $7 D004952
- 650 _2
- $a glycerol $x analogy a deriváty $x analýza $7 D005990
- 650 _2
- $a hmotnostní spektrometrie $x metody $7 D013058
- 650 _2
- $a oleje rostlin $x analýza $7 D010938
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Vaclavik, Lukáš
- 700 1#
- $a Lacina, Ondřej. $7 _AN059513
- 700 1_
- $a Hrbek, Vojtěch
- 700 1_
- $a Riddellová, Kateřina
- 700 1_
- $a Hajšlová, Jana, $d 1952- $7 uzp2006333635
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 402, č. 9 (2012), s. 2871-2883
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22287050 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120815 $b ABA008
- 991 __
- $a 20170410104323 $b ABA008
- 999 __
- $a ok $b bmc $g 946222 $s 781402
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 402 $c 9 $d 2871-2883 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20120815/12/02