Finite element analysis for the evaluation of the structural behaviour, of a prosthesis for trans-tibial amputees
M. Omasta, D. Paloušek, T. Návrat, J. Rosický,
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Amputees MeSH
- Finite Element Analysis MeSH
- Adult MeSH
- Humans MeSH
- Stress, Mechanical MeSH
- Prosthesis Design MeSH
- Prostheses and Implants MeSH
- Tibia MeSH
- Weight-Bearing MeSH
- Check Tag
- Adult MeSH
- Humans MeSH
- Male MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The finite element analysis (FEA) has been identified as a useful tool for the stress and strain behaviour determination in lower limb prosthetics. The residual limb and prosthetic socket interface was the main subject of interest in previous studies. This paper focuses on the finite element analysis for the evaluation of structural behaviour of the Sure-flex™ prosthetic foot and other load-bearing components. A prosthetic socket was not included in the FEA. An approach for the finite element modelling including foot analysis, reverse engineering and material property testing was used. The foot analysis incorporated ground reaction forces measurement, motion analysis and strain gauge analysis. For the material model determination, non-destructive laboratory testing and its FE simulation was used. A new, realistic way of load application is presented along with a detailed investigation of stress distribution in the load-bearing components of the prosthesis. A novel approach for numerical and experimental agreement determination was introduced. This showed differences in the strain on the pylon between the experimental and the numerical model within 30% for the anteroposterior bending and up to 25% for the compression. The highest von Mises stresses were found on the foot-pylon connecting component at toe off. Peak stress of 216MPa occurred on the posterior adjusting screw and maximum stress of 156MPa was found at the neck of the male pyramid.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12024413
- 003
- CZ-PrNML
- 005
- 20121207122902.0
- 007
- ta
- 008
- 120815s2012 enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.medengphy.2011.06.014 $2 doi
- 035 __
- $a (PubMed)21764351
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Omasta, Milan $u Institute of Machine and Industrial Design, Faculty of Mechanical Engineering, Brno University of Technology, Czech Republic. yomast00@stud.fme.vutbr.cz
- 245 10
- $a Finite element analysis for the evaluation of the structural behaviour, of a prosthesis for trans-tibial amputees / $c M. Omasta, D. Paloušek, T. Návrat, J. Rosický,
- 520 9_
- $a The finite element analysis (FEA) has been identified as a useful tool for the stress and strain behaviour determination in lower limb prosthetics. The residual limb and prosthetic socket interface was the main subject of interest in previous studies. This paper focuses on the finite element analysis for the evaluation of structural behaviour of the Sure-flex™ prosthetic foot and other load-bearing components. A prosthetic socket was not included in the FEA. An approach for the finite element modelling including foot analysis, reverse engineering and material property testing was used. The foot analysis incorporated ground reaction forces measurement, motion analysis and strain gauge analysis. For the material model determination, non-destructive laboratory testing and its FE simulation was used. A new, realistic way of load application is presented along with a detailed investigation of stress distribution in the load-bearing components of the prosthesis. A novel approach for numerical and experimental agreement determination was introduced. This showed differences in the strain on the pylon between the experimental and the numerical model within 30% for the anteroposterior bending and up to 25% for the compression. The highest von Mises stresses were found on the foot-pylon connecting component at toe off. Peak stress of 216MPa occurred on the posterior adjusting screw and maximum stress of 156MPa was found at the neck of the male pyramid.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a amputovaní $7 D000674
- 650 _2
- $a analýza metodou konečných prvků $7 D020342
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a protézy a implantáty $7 D019736
- 650 _2
- $a protézy - design $7 D011474
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a tibie $7 D013977
- 650 _2
- $a zatížení muskuloskeletálního systému $7 D016474
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Paloušek, David
- 700 1_
- $a Návrat, Tomáš
- 700 1_
- $a Rosický, Jiří
- 773 0_
- $w MED00008431 $t Medical engineering & physics $x 1873-4030 $g Roč. 34, č. 1 (2012), s. 38-45
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21764351 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120815 $b ABA008
- 991 __
- $a 20121207122937 $b ABA008
- 999 __
- $a ok $b bmc $g 946561 $s 781741
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 34 $c 1 $d 38-45 $i 1873-4030 $m Medical engineering & physics $n Med Eng Phys $x MED00008431
- LZP __
- $a Pubmed-20120815/12/02