Gastric submucosal microdialysis in the detection of rat stomach ischemia--a comparison of the 3H2O efflux technique with metabolic monitoring
N. Cibicek, H. Zivna, E. Vrublova, J. Cibicek, E. Cermakova, V. Palicka,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
- MeSH
- ischemie diagnóza metabolismus MeSH
- krysa rodu rattus MeSH
- mikrodialýza metody MeSH
- potkani Wistar MeSH
- tritium diagnostické užití MeSH
- voda diagnostické užití MeSH
- žaludeční sliznice krevní zásobení metabolismus patologie MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
Microdialysis has been utilized for nutritive blood flow measurements, but both the advantages and disadvantages of various approaches have not been evaluated in parallel in the stomach yet. Our aim was to compare the (3)H(2)O efflux technique with biochemical monitoring during temporary celiac artery occlusion in anesthetized rats. Microdialysis probes were implanted in the gastric submucosa and perfused with (3)H(2)O; samples were analyzed for β-activity, glucose, lactate, pyruvate and glycerol. Gastric mucosa and plasma were subjected to morphometry and analysis of myeloperoxidase, total thiols and lactatdehydrogenase. The most dramatic responses to ischemia were observed in lactate/pyruvate and lactate/glucose (%) ratios (6.1-9.3×, p < 0.0001); the changes in (3)H(2)O efflux and glycerol were less pronounced (1.1-1.7×, p < 0.0001 and < 0.01, respectively). (3)H(2)O efflux correlated best with the lactate/glucose ratio and glucose alone (r = 0.693 and -0.681, respectively, p < 0.0001). A correlation was also found between plasma lactatdehydrogenase and relative glycerol release (r = 0.600, p < 0.05). Myeloperoxidase, lactatdehydrogenase and histology score were increased by ischemia/reperfusion (0.06-0.12 nkat g(-1), p < 0.05, 0.26-0.44 nkat g(-1), p < 0.05 and 1.79-2.33, p < 0.05, respectively), macroscopy and plasma thiols remained unchanged. Microdialysis is useful in monitoring gastric ischemia, metabolic monitoring being superior to the (3)H(2)O efflux technique. The results question the efficacy of the utilized model to produce standardized major gastric damage.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12026150
- 003
- CZ-PrNML
- 005
- 20121207124705.0
- 007
- ta
- 008
- 120817e20100823enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1088/0967-3334/31/10/005 $2 doi
- 035 __
- $a (PubMed)20733248
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Cibicek, Norbert $u Institute of Clinical Biochemistry and Diagnostics, Charles University in Prague, Faculty of Medicine in Hradec Králové and University Hospital Hradec Králové, Czech Republic. norbert.cibicek@upol.cz
- 245 10
- $a Gastric submucosal microdialysis in the detection of rat stomach ischemia--a comparison of the 3H2O efflux technique with metabolic monitoring / $c N. Cibicek, H. Zivna, E. Vrublova, J. Cibicek, E. Cermakova, V. Palicka,
- 520 9_
- $a Microdialysis has been utilized for nutritive blood flow measurements, but both the advantages and disadvantages of various approaches have not been evaluated in parallel in the stomach yet. Our aim was to compare the (3)H(2)O efflux technique with biochemical monitoring during temporary celiac artery occlusion in anesthetized rats. Microdialysis probes were implanted in the gastric submucosa and perfused with (3)H(2)O; samples were analyzed for β-activity, glucose, lactate, pyruvate and glycerol. Gastric mucosa and plasma were subjected to morphometry and analysis of myeloperoxidase, total thiols and lactatdehydrogenase. The most dramatic responses to ischemia were observed in lactate/pyruvate and lactate/glucose (%) ratios (6.1-9.3×, p < 0.0001); the changes in (3)H(2)O efflux and glycerol were less pronounced (1.1-1.7×, p < 0.0001 and < 0.01, respectively). (3)H(2)O efflux correlated best with the lactate/glucose ratio and glucose alone (r = 0.693 and -0.681, respectively, p < 0.0001). A correlation was also found between plasma lactatdehydrogenase and relative glycerol release (r = 0.600, p < 0.05). Myeloperoxidase, lactatdehydrogenase and histology score were increased by ischemia/reperfusion (0.06-0.12 nkat g(-1), p < 0.05, 0.26-0.44 nkat g(-1), p < 0.05 and 1.79-2.33, p < 0.05, respectively), macroscopy and plasma thiols remained unchanged. Microdialysis is useful in monitoring gastric ischemia, metabolic monitoring being superior to the (3)H(2)O efflux technique. The results question the efficacy of the utilized model to produce standardized major gastric damage.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a žaludeční sliznice $x krevní zásobení $x metabolismus $x patologie $7 D005753
- 650 _2
- $a ischemie $x diagnóza $x metabolismus $7 D007511
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a mikrodialýza $x metody $7 D017551
- 650 _2
- $a krysa rodu Rattus $7 D051381
- 650 _2
- $a potkani Wistar $7 D017208
- 650 _2
- $a tritium $x diagnostické užití $7 D014316
- 650 _2
- $a voda $x diagnostické užití $7 D014867
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Zivna, Helena
- 700 1_
- $a Vrublova, Eva
- 700 1_
- $a Cibicek, Jaroslav
- 700 1_
- $a Cermakova, Eva
- 700 1_
- $a Palicka, Vladimir
- 773 0_
- $w MED00181057 $t Physiological measurement $x 1361-6579 $g Roč. 31, č. 10 (20100823), s. 1355-68
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20733248 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20121207124740 $b ABA008
- 999 __
- $a ok $b bmc $g 948192 $s 783496
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 31 $c 10 $d 1355-68 $e 20100823 $i 1361-6579 $m Physiological measurement $n Physiol Meas $x MED00181057
- LZP __
- $a Pubmed-20120817/10/04