Use of a polar ionic liquid as second column for the comprehensive two-dimensional GC separation of PCBs

M. Zapadlo, J. Krupcík, P. Májek, DW. Armstrong, P. Sandra,

. 2010 ; 1217 (37) : 5859-67. [pub] 20100721

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026168

The orthogonality of three columns coupled in two series was studied for the congener specific comprehensive two-dimensional GC separation of polychlorinated biphenyls (PCBs). A non-polar capillary column coated with poly(5%-phenyl-95%-methyl)siloxane was used as the first ((1)D) column in both series. A polar capillary column coated with 70% cyanopropyl-polysilphenylene-siloxane or a capillary column coated with the ionic liquid 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethane-sulfonyl)imide were used as the second ((2)D) columns. Nine multi-congener standard PCB solutions containing subsets of all native 209 PCBs, a mixture of 209 PCBs as well as Aroclor 1242 and 1260 formulations were used to study the orthogonality of both column series. Retention times of the corresponding PCB congeners on (1)D and (2)D columns were used to construct retention time dependences (apex plots) for assessing orthogonality of both columns coupled in series. For a visual assessment of the peak density of PCBs congeners on a retention plane, 2D images were compared. The degree of orthogonality of both column series was, along the visual assessment of distribution of PCBs on the retention plane, evaluated also by Pearson's correlation coefficient, which was found by correlation of retention times t(R,i,2D) and t(R,i,1D) of corresponding PCB congeners on both column series. It was demonstrated that the apolar+ionic liquid column series is almost orthogonal both for the 2D separation of PCBs present in Aroclor 1242 and 1260 formulations as well as for the separation of all of 209 PCBs. All toxic, dioxin-like PCBs, with the exception of PCB 118 that overlaps with PCB 106, were resolved by the apolar/ionic liquid series while on the apolar/polar column series three toxic PCBs overlapped (105+127, 81+148 and 118+106).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12026168
003      
CZ-PrNML
005      
20121207125445.0
007      
ta
008      
120817e20100721ne f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.chroma.2010.07.024 $2 doi
035    __
$a (PubMed)20696431
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Zapadlo, Michal $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Trida 17. listopadu 1192/12, CZ-77146 Olomouc, Czech Republic.
245    10
$a Use of a polar ionic liquid as second column for the comprehensive two-dimensional GC separation of PCBs / $c M. Zapadlo, J. Krupcík, P. Májek, DW. Armstrong, P. Sandra,
520    9_
$a The orthogonality of three columns coupled in two series was studied for the congener specific comprehensive two-dimensional GC separation of polychlorinated biphenyls (PCBs). A non-polar capillary column coated with poly(5%-phenyl-95%-methyl)siloxane was used as the first ((1)D) column in both series. A polar capillary column coated with 70% cyanopropyl-polysilphenylene-siloxane or a capillary column coated with the ionic liquid 1,12-di(tripropylphosphonium)dodecane bis(trifluoromethane-sulfonyl)imide were used as the second ((2)D) columns. Nine multi-congener standard PCB solutions containing subsets of all native 209 PCBs, a mixture of 209 PCBs as well as Aroclor 1242 and 1260 formulations were used to study the orthogonality of both column series. Retention times of the corresponding PCB congeners on (1)D and (2)D columns were used to construct retention time dependences (apex plots) for assessing orthogonality of both columns coupled in series. For a visual assessment of the peak density of PCBs congeners on a retention plane, 2D images were compared. The degree of orthogonality of both column series was, along the visual assessment of distribution of PCBs on the retention plane, evaluated also by Pearson's correlation coefficient, which was found by correlation of retention times t(R,i,2D) and t(R,i,1D) of corresponding PCB congeners on both column series. It was demonstrated that the apolar+ionic liquid column series is almost orthogonal both for the 2D separation of PCBs present in Aroclor 1242 and 1260 formulations as well as for the separation of all of 209 PCBs. All toxic, dioxin-like PCBs, with the exception of PCB 118 that overlaps with PCB 106, were resolved by the apolar/ionic liquid series while on the apolar/polar column series three toxic PCBs overlapped (105+127, 81+148 and 118+106).
650    _2
$a arochlory $x chemie $x izolace a purifikace $7 D001140
650    _2
$a chromatografie plynová $x metody $7 D002849
650    _2
$a iontové kapaliny $x chemie $7 D052578
650    _2
$a polychlorované bifenyly $x chemie $x izolace a purifikace $7 D011078
650    _2
$a siloxany $x chemie $7 D012833
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Krupcík, Ján
700    1_
$a Májek, Pavel
700    1_
$a Armstrong, Daniel W $7 gn_A_00008616
700    1_
$a Sandra, Pat
773    0_
$w MED00004962 $t Journal of chromatography. A $x 1873-3778 $g Roč. 1217, č. 37 (20100721), s. 5859-67
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20696431 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121207125519 $b ABA008
999    __
$a ok $b bmc $g 948210 $s 783514
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 1217 $c 37 $d 5859-67 $e 20100721 $i 1873-3778 $m Journal of chromatography. A, Including electrophoresis and other separation methods $n J Chromatogr A $x MED00004962
LZP    __
$a Pubmed-20120817/10/04

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...