• Je něco špatně v tomto záznamu ?

Women with incorrect pelvic floor statics: a biomechanical answer to the mechanical loading of the vagina-endopelvic fascia complex

K. Jelen, H. Herman, F. Lopot, P. Kubovy, M. Otcenasek, R. Sedlacek,

. 2010 ; 31 (3) : 413-7.

Jazyk angličtina Země Švédsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026302

OBJECTIVE: This work focuses on finding method for detecting the elementary mechanical characteristics of the vagina-endopelvic fascia complex, aimed at providing results for use in optimizing solutions for stability defects of the pelvic floor. MATERIALS AND METHODS: Two experiments have already been carried out that have enabled monitoring of the reaction of tissue complex samples to a selected load. The elastic properties of samples under a simple pull load were evaluated. The monitored property in the first experiment was the maximum reference tension at the moment of rupture of the sample in relation to the non-deformed section. We evaluated data from measurements on 11 samples within the scope of the first experiment. For data processing from the second experiment we used a linear-elastic model of the sample, formed by parallel connection of basic mechanical elements - springs - that represented the endopelvic fascia and the vaginal wall. The relevant rigidities were used for a description of their properties. Five samples were used for this experiment. RESULTS: An important discovery was that the endopelvic fascia tears apart after a longer period of time than the vaginal wall during the pull test. The results show considerable variability among individuals, but the pattern of curves is similar in all test cases. In all measured data we found a rigidity increase zone, a maximum rigidity zone and a gradual rigidity decrease zone before terminal damage in the response. CONCLUSIONS: The results presented here show quite broad interindividual variability of the mechanical properties of the vaginal wall-endopelvic fascia complex. It appears that the mechanical properties of the tissue complex change with number of pregnancies, and are affected by diseases, by physical load or by the presence of other factors, e.g. obesity.

000      
00000naa a2200000 a 4500
001      
bmc12026302
003      
CZ-PrNML
005      
20121210095404.0
007      
ta
008      
120817s2010 sw f 000 0#eng||
009      
AR
035    __
$a (PubMed)20588227
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sw
100    1_
$a Jelen, Karel $u Charles University, Faculty of Physical Education and Sport, Dept. of anatomy and biomechanics, Laboratory of Biomechanics of Extreme Loading, Prague, Czech Republic. jelen@ftvs.cuni.cz
245    10
$a Women with incorrect pelvic floor statics: a biomechanical answer to the mechanical loading of the vagina-endopelvic fascia complex / $c K. Jelen, H. Herman, F. Lopot, P. Kubovy, M. Otcenasek, R. Sedlacek,
520    9_
$a OBJECTIVE: This work focuses on finding method for detecting the elementary mechanical characteristics of the vagina-endopelvic fascia complex, aimed at providing results for use in optimizing solutions for stability defects of the pelvic floor. MATERIALS AND METHODS: Two experiments have already been carried out that have enabled monitoring of the reaction of tissue complex samples to a selected load. The elastic properties of samples under a simple pull load were evaluated. The monitored property in the first experiment was the maximum reference tension at the moment of rupture of the sample in relation to the non-deformed section. We evaluated data from measurements on 11 samples within the scope of the first experiment. For data processing from the second experiment we used a linear-elastic model of the sample, formed by parallel connection of basic mechanical elements - springs - that represented the endopelvic fascia and the vaginal wall. The relevant rigidities were used for a description of their properties. Five samples were used for this experiment. RESULTS: An important discovery was that the endopelvic fascia tears apart after a longer period of time than the vaginal wall during the pull test. The results show considerable variability among individuals, but the pattern of curves is similar in all test cases. In all measured data we found a rigidity increase zone, a maximum rigidity zone and a gradual rigidity decrease zone before terminal damage in the response. CONCLUSIONS: The results presented here show quite broad interindividual variability of the mechanical properties of the vaginal wall-endopelvic fascia complex. It appears that the mechanical properties of the tissue complex change with number of pregnancies, and are affected by diseases, by physical load or by the presence of other factors, e.g. obesity.
650    _2
$a biomechanika $x fyziologie $7 D001696
650    _2
$a fascie $x fyziologie $7 D005205
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a biologické modely $7 D008954
650    _2
$a pánevní dno $x fyziologie $7 D017773
650    _2
$a vagina $x fyziologie $7 D014621
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Herman, Hynek
700    1_
$a Lopot, Frantisek
700    1_
$a Kubovy, Petr
700    1_
$a Otcenasek, Michal
700    1_
$a Sedlacek, Radek
773    0_
$w MED00168352 $t Neuro endocrinology letters $x 0172-780X $g Roč. 31, č. 3 (2010), s. 413-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20588227 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121210095440 $b ABA008
999    __
$a ok $b bmc $g 948344 $s 783648
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 31 $c 3 $d 413-7 $i 0172-780X $m Neuro-endocrinology letters $n Neuro-endocrinol. lett. $x MED00168352
LZP    __
$a Pubmed-20120817/10/04

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...