The relationship between esophageal peristalsis and in vivo intraband pressure measurements in gastric banding patients

M. Fried, SK. Ghosh, M. Gutierrez, K. Dolezalova, T. Widenhouse, G. Gayoso,

. 2010 ; 20 (8) : 1102-9.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12026385
E-zdroje Online Plný text

NLK ProQuest Central od 1997-02-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2010-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-02-01 do Před 1 rokem
Public Health Database (ProQuest) od 1997-02-01 do 2017-12-31

Intraband pressure (IBP) measurement may be a less invasive method to assess esophageal motility response to band adjustment and restrictive integrity of the device in Swedish adjustable gastric band (SAGB) patients. However, the relationship between IBP and esophageal function is not yet established. Our aim was to characterize in vivo IBP-peristalsis associations in SAGB patients. Ten patients in their second postoperative year were prospectively recruited. IBP was measured via percutaneous port, and concurrent esophageal manometry was performed using an 8-channel catheter. Contraction length and amplitude were measured with both methods. The IBP-peristalsis correlation was computed using the R-square of the regression analysis (R (2)) for band volumes ranging from 4 to 9 mL. One hundred ten swallows were studied. Excellent IBP-peristalsis correlation was observed in 6 of 10 patients (267 contractions): contraction length R (2) = 0.8537 and amplitude R (2) = 0.7365 (p-value of slope < 0.001). Mean contraction length was 17 +/- 7 (4-42) s for manometry and 18 +/- 7 (5-43) s for IBP. Mean amplitude was 55 +/- 55 (9-209) mm Hg for manometry and 67 +/- 47 (7-190) mm Hg for IBP. A weak IBP-peristalsis correlation was observed in the remaining four patients: two had impaired lower sphincter relaxation, one had band slippage, and one had disruption of the port needle connection. In vivo IBP measurement may be reliable in the assessment of esophageal peristalsis in response to band adjustments and the restrictive integrity of the device in patients with intact esophageal function. More studies are warranted to completely assess the potential for IBP to be indicative of the presence of band-related complications.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12026385
003      
CZ-PrNML
005      
20130221093236.0
007      
ta
008      
120817s2010 xxu f 000 0#eng||
009      
AR
024    7_
$a 10.1007/s11695-010-0182-3 $2 doi
035    __
$a (PubMed)20490707
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Fried, Martin $u OB klinika & 1st Faculty of Medicine, Charles University, Center for Treatment of Obesity and Metabolic Disorders, Pod Krejcarkem 975, 13000, Prague 3, Czech Republic. docfried@volny.cz
245    14
$a The relationship between esophageal peristalsis and in vivo intraband pressure measurements in gastric banding patients / $c M. Fried, SK. Ghosh, M. Gutierrez, K. Dolezalova, T. Widenhouse, G. Gayoso,
520    9_
$a Intraband pressure (IBP) measurement may be a less invasive method to assess esophageal motility response to band adjustment and restrictive integrity of the device in Swedish adjustable gastric band (SAGB) patients. However, the relationship between IBP and esophageal function is not yet established. Our aim was to characterize in vivo IBP-peristalsis associations in SAGB patients. Ten patients in their second postoperative year were prospectively recruited. IBP was measured via percutaneous port, and concurrent esophageal manometry was performed using an 8-channel catheter. Contraction length and amplitude were measured with both methods. The IBP-peristalsis correlation was computed using the R-square of the regression analysis (R (2)) for band volumes ranging from 4 to 9 mL. One hundred ten swallows were studied. Excellent IBP-peristalsis correlation was observed in 6 of 10 patients (267 contractions): contraction length R (2) = 0.8537 and amplitude R (2) = 0.7365 (p-value of slope < 0.001). Mean contraction length was 17 +/- 7 (4-42) s for manometry and 18 +/- 7 (5-43) s for IBP. Mean amplitude was 55 +/- 55 (9-209) mm Hg for manometry and 67 +/- 47 (7-190) mm Hg for IBP. A weak IBP-peristalsis correlation was observed in the remaining four patients: two had impaired lower sphincter relaxation, one had band slippage, and one had disruption of the port needle connection. In vivo IBP measurement may be reliable in the assessment of esophageal peristalsis in response to band adjustments and the restrictive integrity of the device in patients with intact esophageal function. More studies are warranted to completely assess the potential for IBP to be indicative of the presence of band-related complications.
650    _2
$a dospělí $7 D000328
650    _2
$a polykání $x fyziologie $7 D003679
650    _2
$a poruchy motility jícnu $x diagnóza $x etiologie $7 D015154
650    _2
$a dolní jícnový svěrač $x fyziologie $7 D049630
650    _2
$a ezofágus $x fyziologie $7 D004947
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a gastrointestinální motilita $7 D005769
650    _2
$a gastroplastika $7 D015391
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a manometrie $7 D008365
650    _2
$a lidé středního věku $7 D008875
650    _2
$a morbidní obezita $x patofyziologie $x chirurgie $7 D009767
650    _2
$a peristaltika $x fyziologie $7 D010528
650    _2
$a tlak $7 D011312
650    _2
$a prospektivní studie $7 D011446
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Ghosh, Sudip K
700    1_
$a Gutierrez, Mario
700    1_
$a Dolezalova, Karin
700    1_
$a Widenhouse, Tamara
700    1_
$a Gayoso, Gaspar
773    0_
$w MED00180469 $t Obesity surgery $x 1708-0428 $g Roč. 20, č. 8 (2010), s. 1102-9
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20490707 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20130221093429 $b ABA008
999    __
$a ok $b bmc $g 948427 $s 783731
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 20 $c 8 $d 1102-9 $i 1708-0428 $m Obesity surgery $n Obes Surg $x MED00180469
LZP    __
$a Pubmed-20120817/10/04

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...