-
Je něco špatně v tomto záznamu ?
The relationship between esophageal peristalsis and in vivo intraband pressure measurements in gastric banding patients
M. Fried, SK. Ghosh, M. Gutierrez, K. Dolezalova, T. Widenhouse, G. Gayoso,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 1997-02-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2010-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 1997-02-01 do Před 1 rokem
Public Health Database (ProQuest)
od 1997-02-01 do 2017-12-31
- MeSH
- dolní jícnový svěrač fyziologie MeSH
- dospělí MeSH
- ezofágus fyziologie MeSH
- gastrointestinální motilita MeSH
- gastroplastika MeSH
- lidé středního věku MeSH
- lidé MeSH
- manometrie MeSH
- morbidní obezita patofyziologie chirurgie MeSH
- peristaltika fyziologie MeSH
- polykání fyziologie MeSH
- poruchy motility jícnu diagnóza etiologie MeSH
- prospektivní studie MeSH
- tlak MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Intraband pressure (IBP) measurement may be a less invasive method to assess esophageal motility response to band adjustment and restrictive integrity of the device in Swedish adjustable gastric band (SAGB) patients. However, the relationship between IBP and esophageal function is not yet established. Our aim was to characterize in vivo IBP-peristalsis associations in SAGB patients. Ten patients in their second postoperative year were prospectively recruited. IBP was measured via percutaneous port, and concurrent esophageal manometry was performed using an 8-channel catheter. Contraction length and amplitude were measured with both methods. The IBP-peristalsis correlation was computed using the R-square of the regression analysis (R (2)) for band volumes ranging from 4 to 9 mL. One hundred ten swallows were studied. Excellent IBP-peristalsis correlation was observed in 6 of 10 patients (267 contractions): contraction length R (2) = 0.8537 and amplitude R (2) = 0.7365 (p-value of slope < 0.001). Mean contraction length was 17 +/- 7 (4-42) s for manometry and 18 +/- 7 (5-43) s for IBP. Mean amplitude was 55 +/- 55 (9-209) mm Hg for manometry and 67 +/- 47 (7-190) mm Hg for IBP. A weak IBP-peristalsis correlation was observed in the remaining four patients: two had impaired lower sphincter relaxation, one had band slippage, and one had disruption of the port needle connection. In vivo IBP measurement may be reliable in the assessment of esophageal peristalsis in response to band adjustments and the restrictive integrity of the device in patients with intact esophageal function. More studies are warranted to completely assess the potential for IBP to be indicative of the presence of band-related complications.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12026385
- 003
- CZ-PrNML
- 005
- 20130221093236.0
- 007
- ta
- 008
- 120817s2010 xxu f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s11695-010-0182-3 $2 doi
- 035 __
- $a (PubMed)20490707
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Fried, Martin $u OB klinika & 1st Faculty of Medicine, Charles University, Center for Treatment of Obesity and Metabolic Disorders, Pod Krejcarkem 975, 13000, Prague 3, Czech Republic. docfried@volny.cz
- 245 14
- $a The relationship between esophageal peristalsis and in vivo intraband pressure measurements in gastric banding patients / $c M. Fried, SK. Ghosh, M. Gutierrez, K. Dolezalova, T. Widenhouse, G. Gayoso,
- 520 9_
- $a Intraband pressure (IBP) measurement may be a less invasive method to assess esophageal motility response to band adjustment and restrictive integrity of the device in Swedish adjustable gastric band (SAGB) patients. However, the relationship between IBP and esophageal function is not yet established. Our aim was to characterize in vivo IBP-peristalsis associations in SAGB patients. Ten patients in their second postoperative year were prospectively recruited. IBP was measured via percutaneous port, and concurrent esophageal manometry was performed using an 8-channel catheter. Contraction length and amplitude were measured with both methods. The IBP-peristalsis correlation was computed using the R-square of the regression analysis (R (2)) for band volumes ranging from 4 to 9 mL. One hundred ten swallows were studied. Excellent IBP-peristalsis correlation was observed in 6 of 10 patients (267 contractions): contraction length R (2) = 0.8537 and amplitude R (2) = 0.7365 (p-value of slope < 0.001). Mean contraction length was 17 +/- 7 (4-42) s for manometry and 18 +/- 7 (5-43) s for IBP. Mean amplitude was 55 +/- 55 (9-209) mm Hg for manometry and 67 +/- 47 (7-190) mm Hg for IBP. A weak IBP-peristalsis correlation was observed in the remaining four patients: two had impaired lower sphincter relaxation, one had band slippage, and one had disruption of the port needle connection. In vivo IBP measurement may be reliable in the assessment of esophageal peristalsis in response to band adjustments and the restrictive integrity of the device in patients with intact esophageal function. More studies are warranted to completely assess the potential for IBP to be indicative of the presence of band-related complications.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a polykání $x fyziologie $7 D003679
- 650 _2
- $a poruchy motility jícnu $x diagnóza $x etiologie $7 D015154
- 650 _2
- $a dolní jícnový svěrač $x fyziologie $7 D049630
- 650 _2
- $a ezofágus $x fyziologie $7 D004947
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a gastrointestinální motilita $7 D005769
- 650 _2
- $a gastroplastika $7 D015391
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a manometrie $7 D008365
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a morbidní obezita $x patofyziologie $x chirurgie $7 D009767
- 650 _2
- $a peristaltika $x fyziologie $7 D010528
- 650 _2
- $a tlak $7 D011312
- 650 _2
- $a prospektivní studie $7 D011446
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Ghosh, Sudip K
- 700 1_
- $a Gutierrez, Mario
- 700 1_
- $a Dolezalova, Karin
- 700 1_
- $a Widenhouse, Tamara
- 700 1_
- $a Gayoso, Gaspar
- 773 0_
- $w MED00180469 $t Obesity surgery $x 1708-0428 $g Roč. 20, č. 8 (2010), s. 1102-9
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20490707 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20130221093429 $b ABA008
- 999 __
- $a ok $b bmc $g 948427 $s 783731
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 20 $c 8 $d 1102-9 $i 1708-0428 $m Obesity surgery $n Obes Surg $x MED00180469
- LZP __
- $a Pubmed-20120817/10/04