Je něco špatně v tomto záznamu ?
Antimony and arsenic leaching from secondary lead smelter air-pollution-control residues
V. Ettler, M. Mihaljevic, O. Sebek,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
19723825
DOI
10.1177/0734242x09335704
Knihovny.cz E-zdroje
- MeSH
- antimon analýza izolace a purifikace MeSH
- arsen analýza izolace a purifikace MeSH
- hutnictví MeSH
- látky znečišťující vzduch analýza izolace a purifikace MeSH
- olovo analýza izolace a purifikace MeSH
- průmyslový odpad prevence a kontrola MeSH
- spalování odpadů MeSH
- těžké kovy analýza izolace a purifikace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Environments in the vicinity of the lead (Pb) smelters are contaminated by emissions containing high concentrations of antimony (Sb) and arsenic (As). Air-pollution-control (APC) residues from bag-type filters from a secondary Pb smelter were subjected to leaching experiments to elucidate the controlling mechanisms of Sb and As release. Kinetic batch leaching tests at a liquid-to-solid (L/S) ratio of 10 L kg(- 1) within the time frame of 720 hours and batch leaching at various L/S ratios (ranging from 1 to 1000 L kg(-1)) were performed. In contrast to other inorganic contaminants (Pb, Cd, Zn), less than 1% of the total Sb and As content was leached from the residues. At a L/S ratio of 10, the As and Sb concentrations in the leachates exceeded the EU limit values for non-hazardous waste (0.2 and 0.07 mg L(-1) ). According to PHREEQC-2 calculations, the concentrations of As and Sb are controlled by the precipitation of complex arsenates and antimonates mainly at low L/S ratios. The washing and related chemical/mineralogical transformation of APC residues was suggested as a technological pre-treatment process before their re-smelting in a blast furnace. The Ferrox-like processing of the resulting contaminated process water/leachate was simulated using the PHREEQC-2 code. Significant reduction was obtained in the concentration of some key contaminants (As, Cu, Pb, Zn) related to sorption on newly formed hydrous ferric oxides, whereas Sb and Cd exhibited only limited attenuation.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12026506
- 003
- CZ-PrNML
- 005
- 20121207111908.0
- 007
- ta
- 008
- 120817s2010 enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1177/0734242x09335704 $2 doi
- 035 __
- $a (PubMed)19723825
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Ettler, Vojtech $u Institute of Geochemistry, Mineralogy and Mineral Resources, Charles University, Prague, Czech Republic. ettler@natur.cuni.cz
- 245 10
- $a Antimony and arsenic leaching from secondary lead smelter air-pollution-control residues / $c V. Ettler, M. Mihaljevic, O. Sebek,
- 520 9_
- $a Environments in the vicinity of the lead (Pb) smelters are contaminated by emissions containing high concentrations of antimony (Sb) and arsenic (As). Air-pollution-control (APC) residues from bag-type filters from a secondary Pb smelter were subjected to leaching experiments to elucidate the controlling mechanisms of Sb and As release. Kinetic batch leaching tests at a liquid-to-solid (L/S) ratio of 10 L kg(- 1) within the time frame of 720 hours and batch leaching at various L/S ratios (ranging from 1 to 1000 L kg(-1)) were performed. In contrast to other inorganic contaminants (Pb, Cd, Zn), less than 1% of the total Sb and As content was leached from the residues. At a L/S ratio of 10, the As and Sb concentrations in the leachates exceeded the EU limit values for non-hazardous waste (0.2 and 0.07 mg L(-1) ). According to PHREEQC-2 calculations, the concentrations of As and Sb are controlled by the precipitation of complex arsenates and antimonates mainly at low L/S ratios. The washing and related chemical/mineralogical transformation of APC residues was suggested as a technological pre-treatment process before their re-smelting in a blast furnace. The Ferrox-like processing of the resulting contaminated process water/leachate was simulated using the PHREEQC-2 code. Significant reduction was obtained in the concentration of some key contaminants (As, Cu, Pb, Zn) related to sorption on newly formed hydrous ferric oxides, whereas Sb and Cd exhibited only limited attenuation.
- 650 _2
- $a látky znečišťující vzduch $x analýza $x izolace a purifikace $7 D000393
- 650 _2
- $a antimon $x analýza $x izolace a purifikace $7 D000965
- 650 _2
- $a arsen $x analýza $x izolace a purifikace $7 D001151
- 650 _2
- $a spalování odpadů $7 D017745
- 650 _2
- $a průmyslový odpad $x prevence a kontrola $7 D007220
- 650 _2
- $a olovo $x analýza $x izolace a purifikace $7 D007854
- 650 _2
- $a hutnictví $7 D008669
- 650 _2
- $a těžké kovy $x analýza $x izolace a purifikace $7 D019216
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Mihaljevic, Martin
- 700 1_
- $a Sebek, Ondrej
- 773 0_
- $w MED00181101 $t Waste management & research : the journal of the International Solid Wastes and Public Cleansing Association, ISWA $x 1399-3070 $g Roč. 28, č. 7 (2010), s. 587-95
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/19723825 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20121207111942 $b ABA008
- 999 __
- $a ok $b bmc $g 948548 $s 783852
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 28 $c 7 $d 587-95 $i 1399-3070 $m Waste management & research. $n Waste Manag Res $x MED00181101
- LZP __
- $a Pubmed-20120817/10/04