Tandem mass spectrometry identification and LC-MS quantification of intact cytokinin nucleotides in K-562 human leukemia cells
T. Béres, M. Zatloukal, J. Voller, P. Niemann, MC. Gahsche, P. Tarkowski, O. Novák, J. Hanuš, M. Strnad, K. Doležal,
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Chromatography, Liquid MeSH
- Cytokinins analysis chemistry MeSH
- Mass Spectrometry MeSH
- Humans MeSH
- Molecular Structure MeSH
- Cell Line, Tumor MeSH
- Nucleotides analysis chemistry MeSH
- Tandem Mass Spectrometry MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
We describe here a new reversed-phase high-performance liquid chromatography with mass spectrometry detection method for quantifying intact cytokinin nucleotides in human K-562 leukemia cells. Tandem mass spectrometry was used to identify the intracellular metabolites (cytokinin monophosphorylated, diphosphorylated, and triphosphorylated nucleotides) in riboside-treated cells. For the protein precipitation and sample preparation, a trichloroacetic acid extraction method is used. Samples are then back-extracted with diethyl ether, lyophilized, reconstituted, and injected into the LC system. Analytes were quantified in negative selected ion monitoring mode using a single quadrupole mass spectrometer. The method was validated in terms of retention time stabilities, limits of detection, linearity, recovery, and analytical accuracy. The developed method was linear in the range of 1-1,000 pmol for all studied compounds. The limits of detection for the analytes vary from 0.2 to 0.6 pmol.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12026821
- 003
- CZ-PrNML
- 005
- 20170410122329.0
- 007
- ta
- 008
- 120816s2010 gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-010-4126-5 $2 doi
- 035 __
- $a (PubMed)20821313
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Béreš, Tibor $u Laboratory of Growth Regulators, IEB AS CR and Palacký University, Šlechtitelů 11, 78371 Olomouc, Czech Republic. $7 xx0119829
- 245 10
- $a Tandem mass spectrometry identification and LC-MS quantification of intact cytokinin nucleotides in K-562 human leukemia cells / $c T. Béres, M. Zatloukal, J. Voller, P. Niemann, MC. Gahsche, P. Tarkowski, O. Novák, J. Hanuš, M. Strnad, K. Doležal,
- 520 9_
- $a We describe here a new reversed-phase high-performance liquid chromatography with mass spectrometry detection method for quantifying intact cytokinin nucleotides in human K-562 leukemia cells. Tandem mass spectrometry was used to identify the intracellular metabolites (cytokinin monophosphorylated, diphosphorylated, and triphosphorylated nucleotides) in riboside-treated cells. For the protein precipitation and sample preparation, a trichloroacetic acid extraction method is used. Samples are then back-extracted with diethyl ether, lyophilized, reconstituted, and injected into the LC system. Analytes were quantified in negative selected ion monitoring mode using a single quadrupole mass spectrometer. The method was validated in terms of retention time stabilities, limits of detection, linearity, recovery, and analytical accuracy. The developed method was linear in the range of 1-1,000 pmol for all studied compounds. The limits of detection for the analytes vary from 0.2 to 0.6 pmol.
- 650 _2
- $a nádorové buněčné linie $7 D045744
- 650 _2
- $a chromatografie kapalinová $7 D002853
- 650 _2
- $a cytokininy $x analýza $x chemie $7 D003583
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hmotnostní spektrometrie $7 D013058
- 650 _2
- $a molekulární struktura $7 D015394
- 650 _2
- $a nukleotidy $x analýza $x chemie $7 D009711
- 650 _2
- $a tandemová hmotnostní spektrometrie $7 D053719
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Zatloukal, Marek $7 xx0113001
- 700 1_
- $a Voller, Jiří $7 _AN043406
- 700 1_
- $a Niemann, Percy
- 700 1_
- $a Gahsche, Marie Christin
- 700 1_
- $a Tarkowski, Petr, $d 1976- $7 xx0119830
- 700 1_
- $a Novák, Ondřej
- 700 1_
- $a Hanuš, Jan $7 _AN084249
- 700 1_
- $a Strnad, Miroslav, $d 1958- $7 jn20010309068
- 700 1_
- $a Doležal, Karel, $d 1967- $7 xx0100056
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 398, č. 5 (2010), s. 2071-2080
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20821313 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120816 $b ABA008
- 991 __
- $a 20170410122627 $b ABA008
- 999 __
- $a ok $b bmc $g 948863 $s 784167
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 398 $c 5 $d 2071-2080 $e 20100907 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $b NLK113 $a Pubmed-20120816/11/01