Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene
P. Odraska, L. Dolezalova, P. Piler, M. Oravec, L. Blaha,
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
21468422
DOI
10.1039/c0em00660b
Knihovny.cz E-resources
- MeSH
- Adsorption MeSH
- Antineoplastic Agents, Alkylating analysis chemistry MeSH
- Cyclophosphamide analysis chemistry MeSH
- Drug Industry MeSH
- Filtration instrumentation MeSH
- Air Pollutants, Occupational analysis chemistry MeSH
- Humans MeSH
- Environmental Monitoring instrumentation methods MeSH
- Workplace statistics & numerical data MeSH
- Occupational Exposure prevention & control statistics & numerical data MeSH
- Air Pollution, Indoor analysis statistics & numerical data MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The main objective of the study was to evaluate the applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide (CP) in the hospital working environment. For this purpose, air contamination of Masaryk Memorial Cancer Institute (Czech Republic) was monitored using the sampling apparatus containing the samplers described above. In addition, the surface contamination was also determined using the wipe sampling technique. During the monitoring, contamination of three different workplaces (storage room, preparation room and outpatient clinic) was studied. Using Strata X solid sorbent tubes, airborne CP was determined in all (n = 5) samples collected at the outpatient clinic over a 5 day monitoring period (concentration range: 0.3-4.3 ng m(-3)). Other samplers (including PTFE filters) did not collect any detectable amount of CP (the limit of detection, LOD ≤ 0.1 ng m(-3)). Negative results detected at filter samples indicate that CP determined at Strata X samples was most probably of gaseous origin. Surface contamination ranged from <2 to 19, <8 to 418 and 133-15,500 pg cm(-2) at the storage room, preparation room and outpatient clinic, respectively. The study showed that evaporation of antineoplastic drugs should not be neglected, albeit the concentrations determined in our study are relatively low. Therefore, proper monitoring of airborne contamination should involve simultaneous sampling of both particle-bonded and gaseous phases. In this way, Strata X sorbent tubes seem to be an effective tool for the sampling of gaseous CP in the indoor air.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027646
- 003
- CZ-PrNML
- 005
- 20130503225735.0
- 007
- ta
- 008
- 120817e20110406enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1039/c0em00660b $2 doi
- 035 __
- $a (PubMed)21468422
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Odráška, Pavel. $7 _AN042158 $u Masaryk Memorial Cancer Institute, Zluty kopec 7, Brno, Czech Republic. odraska@mou.cz
- 245 10
- $a Utilization of the solid sorbent media in monitoring of airborne cyclophosphamide concentrations and the implications for occupational hygiene / $c P. Odraska, L. Dolezalova, P. Piler, M. Oravec, L. Blaha,
- 520 9_
- $a The main objective of the study was to evaluate the applicability of two solid sorbent media (Anasorb 708 and Strata X), the impinger filled with distilled water and PTFE filters for determination of airborne cyclophosphamide (CP) in the hospital working environment. For this purpose, air contamination of Masaryk Memorial Cancer Institute (Czech Republic) was monitored using the sampling apparatus containing the samplers described above. In addition, the surface contamination was also determined using the wipe sampling technique. During the monitoring, contamination of three different workplaces (storage room, preparation room and outpatient clinic) was studied. Using Strata X solid sorbent tubes, airborne CP was determined in all (n = 5) samples collected at the outpatient clinic over a 5 day monitoring period (concentration range: 0.3-4.3 ng m(-3)). Other samplers (including PTFE filters) did not collect any detectable amount of CP (the limit of detection, LOD ≤ 0.1 ng m(-3)). Negative results detected at filter samples indicate that CP determined at Strata X samples was most probably of gaseous origin. Surface contamination ranged from <2 to 19, <8 to 418 and 133-15,500 pg cm(-2) at the storage room, preparation room and outpatient clinic, respectively. The study showed that evaporation of antineoplastic drugs should not be neglected, albeit the concentrations determined in our study are relatively low. Therefore, proper monitoring of airborne contamination should involve simultaneous sampling of both particle-bonded and gaseous phases. In this way, Strata X sorbent tubes seem to be an effective tool for the sampling of gaseous CP in the indoor air.
- 650 _2
- $a adsorpce $7 D000327
- 650 _2
- $a látky znečišťující vzduch v pracovním prostředí $x analýza $x chemie $7 D000395
- 650 _2
- $a znečištění vzduchu ve vnitřním prostředí $x analýza $x statistika a číselné údaje $7 D016902
- 650 _2
- $a alkylační protinádorové látky $x analýza $x chemie $7 D018906
- 650 _2
- $a cyklofosfamid $x analýza $x chemie $7 D003520
- 650 _2
- $a farmaceutický průmysl $7 D004345
- 650 _2
- $a monitorování životního prostředí $x přístrojové vybavení $x metody $7 D004784
- 650 _2
- $a filtrace $x přístrojové vybavení $7 D005374
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a pracovní expozice $x prevence a kontrola $x statistika a číselné údaje $7 D016273
- 650 _2
- $a pracoviště $x statistika a číselné údaje $7 D017132
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Doležalová, Lenka $7 xx0104110
- 700 1_
- $a Piler, Pavel
- 700 1#
- $a Oravec, Michal. $7 _AN042161
- 700 1_
- $a Bláha, Luděk, $d 1972- $7 xx0084400
- 773 0_
- $w MED00006489 $t Journal of environmental monitoring : JEM $x 1464-0333 $g Roč. 13, č. 5 (20110406), s. 1480-7
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21468422 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20130503230040 $b ABA008
- 999 __
- $a ok $b bmc $g 949688 $s 784992
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 13 $c 5 $d 1480-7 $e 20110406 $i 1464-0333 $m Journal of environmental monitoring $n J Environ Monit $x MED00006489
- LZP __
- $a Pubmed-20120817/11/03