Results of the 2010 National Radiation Protection Institute intercomparison of radon and its short-lived decay product continuous monitors
K. Jílek, M. Marušiaková,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
PubMed
21471124
DOI
10.1093/rpd/ncr064
Knihovny.cz E-zdroje
- MeSH
- časové faktory MeSH
- lidé MeSH
- monitorování radiace přístrojové vybavení normy MeSH
- plyny analýza MeSH
- radiační ochrana přístrojové vybavení normy MeSH
- radioaktivní látky znečišťující vzduch analýza MeSH
- radon analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
During the Sixth European Conference on Protection Against Radon at Home and at Work held in autumn 2010 in Prague, the first intercomparison of continuous radon and its short-lived decay product monitors was organised and held by the Natural Radiation Division of the National Radiation Protection Institute (NRPI) in Prague. Eight laboratories submitted eight continuous radon monitors, two electronic monitors, three passive integral systems based on charcoal and three continuous radon short-lived decay product monitors. The intercomparison included exposures to both the radon gas concentration and equivalent equilibrium radon concentration (EEC) under different ambient conditions similar to the ones in dwellings. In particular, the influence of the equilibrium factor F, unattached fraction of EEC f(p) and absolute air humidity were investigated. The results of the radon gas measurements were performed on a calibration level of about 8 kBq m(-3). The results of all monitors were compared with the reference NRPI monitor.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12028376
- 003
- CZ-PrNML
- 005
- 20121210112442.0
- 007
- ta
- 008
- 120817e20110406enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1093/rpd/ncr064 $2 doi
- 035 __
- $a (PubMed)21471124
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Jílek, K $u National Radiation Protection Institute, Bartoškova 28, Prague 140 00, Czech Republic. karel.jilek@suro.cz
- 245 10
- $a Results of the 2010 National Radiation Protection Institute intercomparison of radon and its short-lived decay product continuous monitors / $c K. Jílek, M. Marušiaková,
- 520 9_
- $a During the Sixth European Conference on Protection Against Radon at Home and at Work held in autumn 2010 in Prague, the first intercomparison of continuous radon and its short-lived decay product monitors was organised and held by the Natural Radiation Division of the National Radiation Protection Institute (NRPI) in Prague. Eight laboratories submitted eight continuous radon monitors, two electronic monitors, three passive integral systems based on charcoal and three continuous radon short-lived decay product monitors. The intercomparison included exposures to both the radon gas concentration and equivalent equilibrium radon concentration (EEC) under different ambient conditions similar to the ones in dwellings. In particular, the influence of the equilibrium factor F, unattached fraction of EEC f(p) and absolute air humidity were investigated. The results of the radon gas measurements were performed on a calibration level of about 8 kBq m(-3). The results of all monitors were compared with the reference NRPI monitor.
- 650 _2
- $a radioaktivní látky znečišťující vzduch $x analýza $7 D000396
- 650 _2
- $a plyny $x analýza $7 D005740
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a monitorování radiace $x přístrojové vybavení $x normy $7 D011834
- 650 _2
- $a radiační ochrana $x přístrojové vybavení $x normy $7 D011835
- 650 _2
- $a radon $x analýza $7 D011886
- 650 _2
- $a časové faktory $7 D013997
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Marušiaková, M
- 773 0_
- $w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 145, č. 2-3 (20110406), s. 273-9
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21471124 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20121210112519 $b ABA008
- 999 __
- $a ok $b bmc $g 950418 $s 785722
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 145 $c 2-3 $d 273-9 $e 20110406 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
- LZP __
- $a Pubmed-20120817/11/04