-
Je něco špatně v tomto záznamu ?
Stabilizing agents for calibration in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry
H. Zelinková, R. Červenka, J. Komárek
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2001
Free Medical Journals
od 2000
PubMed Central
od 2000
Europe PubMed Central
od 2000
ProQuest Central
od 2012-01-01
Open Access Digital Library
od 2000-01-01 do 2012-01-02
Open Access Digital Library
od 2001-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2012-01-03
Medline Complete (EBSCOhost)
od 2012-01-01
Health & Medicine (ProQuest)
od 2012-01-01
Wiley-Blackwell Open Access Titles
od 2000
ROAD: Directory of Open Access Scholarly Resources
od 2001
PubMed
22654606
DOI
10.1100/2012/439875
Knihovny.cz E-zdroje
- MeSH
- kalibrace MeSH
- pomocné látky chemie MeSH
- rtuť analýza MeSH
- spektrofotometrie atomová metody MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L(-1) TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12034465
- 003
- CZ-PrNML
- 005
- 20160626101419.0
- 007
- ta
- 008
- 121023s2012 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1100/2012/439875 $2 doi
- 035 __
- $a (PubMed)22654606
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Zelinková, Hana $u Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 61137 Brno, Czech Republic
- 245 10
- $a Stabilizing agents for calibration in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry / $c H. Zelinková, R. Červenka, J. Komárek
- 520 9_
- $a Tetramethylene dithiocarbamate (TMDTC), diethyldithiocarbamate (DEDTC), and thiourea were investigated as stabilizing agents for calibration purposes in the determination of mercury using solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS). These agents were used for complexation of mercury in calibration solutions and its thermal stabilization in a solid sampling platform. The calibration solutions had the form of methyl isobutyl ketone (MIBK) extracts or MIBK-methanol solutions with the TMDTC and DEDTC chelates and aqueous solutions with thiourea complexes. The best results were obtained for MIBK-methanol solutions in the presence of 2.5 g L(-1) TMDTC. The surface of graphite platforms for solid sampling was modified with palladium or rhenium by using electrodeposition from a drop of solutions. The Re modifier is preferable due to a higher lifetime of platform coating. A new SS-ETAAS procedure using the direct sampling of solid samples into a platform with an Re modified graphite surface and the calibration against MIBK-methanol solutions in the presence of TMDTC is proposed for the determination of mercury content in solid environmental samples, such as soil and plants.
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a pomocné látky $x chemie $7 D005079
- 650 _2
- $a rtuť $x analýza $7 D008628
- 650 _2
- $a spektrofotometrie atomová $x metody $7 D013054
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Červenka, Rostislav $7 xx0148448 $u Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 61137 Brno, Czech Republic
- 700 1_
- $a Komárek, Josef $7 _AN056300 $u Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 61137 Brno, Czech Republic
- 773 0_
- $w MED00181094 $t TheScientificWorldJournal $x 1537-744X $g Roč. 2012(2012), s. 439875
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22654606 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20121023 $b ABA008
- 991 __
- $a 20160626101604 $b ABA008
- 999 __
- $a ok $b bmc $g 956475 $s 791962
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 2012 $d 439875 $i 1537-744X $m TheScientificWorldJournal $n ScientificWorldJournal $x MED00181094
- LZP __
- $b NLK122 $a Pubmed-20121023