• Je něco špatně v tomto záznamu ?

Rapid determination of ambrisentan enantiomers by enantioselective liquid chromatography using cellulose-based chiral stationary phase in reverse phase mode

M. Douša, P. Gibala

. 2012 ; 35 (7) : 798-803.

Jazyk angličtina Země Německo

Typ dokumentu hodnotící studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc12034555

A sensitive, specific, and rapid high-performance liquid chromatography (HPLC) method for the determination of ambrisentan enantiomers has been developed and validated. Six chiral columns were tested in a reversed-phase system. Excellent enantioseparation with the resolution more than 2.5 was achieved on Chiralcel OZ-3R (cellulose 3-chloro-4-methylphenylcarbamate) using mixture of 20 mM sodium formate (pH 3.0) with acetonitrile (55:45; v/v). Validation of the HPLC method including linearity, limit of detection, limit of quantification, precision, accuracy, and selectivity was performed according to the International Conference on Harmonisation (ICH) guidelines. The method has an advantage of a very quick chromatographic separation (less than 6 min) and therefore is highly suitable for routine determination of (R)-ambrisentan in enantiopure active pharmaceutical ingredient (S)-ambrisentan.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12034555
003      
CZ-PrNML
005      
20160818062142.0
007      
ta
008      
121023s2012 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jssc.201101062 $2 doi
035    __
$a (PubMed)22532347
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Douša, Michal, $d 1968- $7 xx0060122 $u Zentiva, Praha, Czech Republic. hplc@hplc.cz
245    10
$a Rapid determination of ambrisentan enantiomers by enantioselective liquid chromatography using cellulose-based chiral stationary phase in reverse phase mode / $c M. Douša, P. Gibala
520    9_
$a A sensitive, specific, and rapid high-performance liquid chromatography (HPLC) method for the determination of ambrisentan enantiomers has been developed and validated. Six chiral columns were tested in a reversed-phase system. Excellent enantioseparation with the resolution more than 2.5 was achieved on Chiralcel OZ-3R (cellulose 3-chloro-4-methylphenylcarbamate) using mixture of 20 mM sodium formate (pH 3.0) with acetonitrile (55:45; v/v). Validation of the HPLC method including linearity, limit of detection, limit of quantification, precision, accuracy, and selectivity was performed according to the International Conference on Harmonisation (ICH) guidelines. The method has an advantage of a very quick chromatographic separation (less than 6 min) and therefore is highly suitable for routine determination of (R)-ambrisentan in enantiopure active pharmaceutical ingredient (S)-ambrisentan.
650    _2
$a adsorpce $7 D000327
650    _2
$a celulosa $x chemie $7 D002482
650    _2
$a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $7 D002851
650    _2
$a chromatografie s reverzní fází $x přístrojové vybavení $x metody $7 D056148
650    _2
$a fenylpropionáty $x chemie $7 D010666
650    _2
$a pyridaziny $x chemie $7 D011724
650    _2
$a stereoizomerie $7 D013237
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
700    1_
$a Gibala, Petr $u Zentiva, Praha, Czech Republic
773    0_
$w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 35, č. 7 (2012), s. 798-803
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22532347 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20121023 $b ABA008
991    __
$a 20160818062436 $b ABA008
999    __
$a ok $b bmc $g 956565 $s 792052
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 35 $c 7 $d 798-803 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
LZP    __
$b NLK122 $a Pubmed-20121023

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...