Je něco špatně v tomto záznamu ?
Surface treatment by electric discharge machining of Ti-6Al-4V alloy for potential application in orthopaedics
P. Harcuba, L. Bačáková, J. Stráský, M. Bačáková, K. Novotná, M. Janeček,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- biokompatibilní materiály chemie MeSH
- biokompatibilní potahované materiály chemie MeSH
- kosti a kostní tkáň MeSH
- lidé MeSH
- povrchové vlastnosti MeSH
- protézy a implantáty MeSH
- slitiny chemie MeSH
- testování materiálů MeSH
- titan chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
This study investigated the properties of Ti-6Al-4V alloy after surface treatment by the electric discharge machining (EDM) process. The EDM process with high peak currents proved to induce surface macro-roughness and to cause chemical changes to the surface. Evaluations were made of the mechanical properties by means of tensile tests, and of surface roughness for different peak currents of the EDM process. The EDM process with peak current of 29 A was found to induce sufficient surface roughness, and to have a low adverse effect on tensile properties. The chemical changes were studied by scanning electron microscopy equipped with an energy dispersive X-ray analyser (EDX). The surface of the benchmark samples was obtained by plasma-spraying a titanium dioxide coating. An investigation of the biocompatibility of the surface-treated Ti-6Al-4V samples in cultures of human osteoblast-like MG 63 cells revealed that the samples modified by EDM provided better substrates for the adhesion, growth and viability of MG 63 cells than the TiO2 coated surface. Thus, EDM treatment can be considered as a promising surface modification to orthopaedic implants, in which good integration with the surrounding bone tissue is required.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12034732
- 003
- CZ-PrNML
- 005
- 20121207121735.0
- 007
- ta
- 008
- 121023s2012 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.jmbbm.2011.07.001 $2 doi
- 035 __
- $a (PubMed)22340689
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Harcuba, Petr $u Charles University, Department of Physics of Materials, Prague, Czech Republic.
- 245 10
- $a Surface treatment by electric discharge machining of Ti-6Al-4V alloy for potential application in orthopaedics / $c P. Harcuba, L. Bačáková, J. Stráský, M. Bačáková, K. Novotná, M. Janeček,
- 520 9_
- $a This study investigated the properties of Ti-6Al-4V alloy after surface treatment by the electric discharge machining (EDM) process. The EDM process with high peak currents proved to induce surface macro-roughness and to cause chemical changes to the surface. Evaluations were made of the mechanical properties by means of tensile tests, and of surface roughness for different peak currents of the EDM process. The EDM process with peak current of 29 A was found to induce sufficient surface roughness, and to have a low adverse effect on tensile properties. The chemical changes were studied by scanning electron microscopy equipped with an energy dispersive X-ray analyser (EDX). The surface of the benchmark samples was obtained by plasma-spraying a titanium dioxide coating. An investigation of the biocompatibility of the surface-treated Ti-6Al-4V samples in cultures of human osteoblast-like MG 63 cells revealed that the samples modified by EDM provided better substrates for the adhesion, growth and viability of MG 63 cells than the TiO2 coated surface. Thus, EDM treatment can be considered as a promising surface modification to orthopaedic implants, in which good integration with the surrounding bone tissue is required.
- 650 _2
- $a slitiny $x chemie $7 D000497
- 650 _2
- $a biokompatibilní materiály $x chemie $7 D001672
- 650 _2
- $a kosti a kostní tkáň $7 D001842
- 650 _2
- $a biokompatibilní potahované materiály $x chemie $7 D020099
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a protézy a implantáty $7 D019736
- 650 _2
- $a povrchové vlastnosti $7 D013499
- 650 _2
- $a titan $x chemie $7 D014025
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Bačáková, Lucie
- 700 1_
- $a Stráský, Josef
- 700 1_
- $a Bačáková, Markéta
- 700 1_
- $a Novotná, Katarína
- 700 1_
- $a Janeček, Miloš
- 773 0_
- $w MED00166961 $t Journal of the mechanical behavior of biomedical materials $x 1878-0180 $g Roč. 7(2012), s. 96-105
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22340689 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a
- 990 __
- $a 20121023 $b ABA008
- 991 __
- $a 20121207121810 $b ABA008
- 999 __
- $a ok $b bmc $g 956742 $s 792229
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 7 $d 96-105 $i 1878-0180 $m Journal of the mechanical behavior of biomedical materials $n J Mech Behav Biomed Mater $x MED00166961
- LZP __
- $a Pubmed-20121023