Plastination with silicone method S 10--monitoring and analysis causes of failure

M. Miklosová, V. Miklos

. 2004 ; 148 (2) : 237-238.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13003804

Plastination is in some cases unsuccessful. The goal of this work was to monitor, to describe and to analyse the reasons of S10 plastination method failure. We prepared the silicone-impregnated specimens using the standard silicone method S 10. The causes of bad preparation are numerous. Usual defects produced during plastination process are the changes in the bulk, the changes in the colour and other visible defects (e.g. deformations, spots on the organs surface). The frequent reasons for these defects are: unsuitable temperature, using of old bad fixed formaldehyde specimens and too long gas-curing procedure. The knowledge of reasons of unsuccessful plastination is important condition for achievement the good results.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13003804
003      
CZ-PrNML
005      
20130220092622.0
007      
ta
008      
130128s2004 xr o f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2004.048 $2 doi
035    __
$a (PubMed)15744385
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Miklošová, Mária. $7 xx0191265 $u Department of Anatomy, Medical Faculty, University of P. I. Safarík, Kosice, Slovak Republic
245    10
$a Plastination with silicone method S 10--monitoring and analysis causes of failure / $c M. Miklosová, V. Miklos
520    9_
$a Plastination is in some cases unsuccessful. The goal of this work was to monitor, to describe and to analyse the reasons of S10 plastination method failure. We prepared the silicone-impregnated specimens using the standard silicone method S 10. The causes of bad preparation are numerous. Usual defects produced during plastination process are the changes in the bulk, the changes in the colour and other visible defects (e.g. deformations, spots on the organs surface). The frequent reasons for these defects are: unsuitable temperature, using of old bad fixed formaldehyde specimens and too long gas-curing procedure. The knowledge of reasons of unsuccessful plastination is important condition for achievement the good results.
650    _2
$a histologické techniky $7 D006652
650    _2
$a lidé $7 D006801
650    _2
$a zalévání tkání plastickou hmotou $x metody $7 D016613
650    _2
$a ochrana biologická $7 D011309
650    _2
$a silikony $7 D012828
655    _2
$a časopisecké články $7 D016428
700    1_
$a Mikloš, Vojtech. $7 _AN071340 $u Technical University, Kosice, Slovak Republic
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 148, č. 2 (2004), s. 237-238
910    __
$a ABA008 $b A 1502 $c sign $y 3 $z 0
990    __
$a 20130128 $b ABA008
991    __
$a 20130220092813 $b ABA008
999    __
$a ok $b bmc $g 966458 $s 801999
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2004 $b 148 $c 2 $d 237-238 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK138 $a Pubmed-20130128

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...