Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs

H. Brzobohatá, J. Prokop, M. Horák, A. Jancárek, J. Velemínská,

. 2012 ; 36 (3) : 801-6.

Jazyk angličtina Země Chorvatsko

Typ dokumentu časopisecké články, práce podpořená grantem, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc13012351

The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.

000      
00000naa a2200000 a 4500
001      
bmc13012351
003      
CZ-PrNML
005      
20130410101837.0
007      
ta
008      
130404s2012 ci f 000 0|eng||
009      
AR
035    __
$a (PubMed)23213936
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ci
100    1_
$a Brzobohatá, Hana $u Charles University, Faculty of Science, Department of Anthropology and Human Genetics, Prague, Czech Republic. brzobohata@arup.cas.cz
245    10
$a Accuracy and benefits of 3D bone surface modelling: a comparison of two methods of surface data acquisition reconstructed by laser scanning and computed tomography outputs / $c H. Brzobohatá, J. Prokop, M. Horák, A. Jancárek, J. Velemínská,
520    9_
$a The aim of this study is to compare two different methods of frontal bone surface model acquisition. Three dimensional models acquired by laser scanning were compared with models of the same bones acquired by virtual replicas reconstructed from a sequence of computed tomography (CT) images. The influence of volumetric CT data processing (namely thresholding), which immediately preceded the generation of the three-dimensional surface model, was also considered and explored in detail in one sample. Despite identifying certain areas where both models showed deviations across all samples, their conformity can be generally classified as satisfactory, and the differences can be regarded as minimal. The average deviation of registered surface models was 0.27 mm for 90% of the data, and its value was therefore very close to the resolution of the laser scanner used.
650    _2
$a antropologie fyzická $x přístrojové vybavení $7 D000885
650    _2
$a čelní kost $x anatomie a histologie $x radiografie $7 D005624
650    _2
$a lidé $7 D006801
650    _2
$a zobrazování trojrozměrné $x metody $x normy $7 D021621
650    _2
$a lasery $7 D007834
650    12
$a anatomické modely $7 D008953
650    _2
$a počítačová rentgenová tomografie $x metody $x normy $7 D014057
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a validační studie $7 D023361
700    1_
$a Prokop, Josef $u -
700    1_
$a Horák, Martin $u -
700    1_
$a Jancárek, Alexandr $u -
700    1_
$a Velemínská, Jana $u -
773    0_
$w MED00180201 $t Collegium antropologicum $x 0350-6134 $g Roč. 36, č. 3 (2012), s. 801-6
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23213936 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130404 $b ABA008
991    __
$a 20130410102107 $b ABA008
999    __
$a ok $b bmc $g 975549 $s 810632
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 36 $c 3 $d 801-6 $i 0350-6134 $m Collegium antropologicum $n Coll Antropol $x MED00180201
LZP    __
$a Pubmed-20130404

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...