Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model

P. Ostadal, M. Mlcek, F. Holy, S. Horakova, S. Kralovec, J. Skoda, J. Petru, A. Kruger, V. Hrachovina, T. Svoboda, O. Kittnar, VY. Reddy, P. Neuzil,

. 2012 ; 5 (6) : 1202-6. (Arrhythmia and electrophysiology)

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13012403

BACKGROUND: Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS AND RESULTS: Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. CONCLUSIONS: Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13012403
003      
CZ-PrNML
005      
20130625121007.0
007      
ta
008      
130404s2012 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1161/circep.112.973123 $2 doi
035    __
$a (PubMed)23051839
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Ošťádal, Petr. $7 xx0036674 $u Cardiovascular Center, Na Homolce Hospital, 15030 Prague, Czech Republic. ostadal.petr@gmail.com
245    10
$a Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model / $c P. Ostadal, M. Mlcek, F. Holy, S. Horakova, S. Kralovec, J. Skoda, J. Petru, A. Kruger, V. Hrachovina, T. Svoboda, O. Kittnar, VY. Reddy, P. Neuzil,
520    9_
$a BACKGROUND: Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS AND RESULTS: Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. CONCLUSIONS: Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation.
650    _2
$a zvířata $7 D000818
650    _2
$a aorta $x patofyziologie $7 D001011
650    12
$a mimotělní membránová oxygenace $7 D015199
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a srdeční síně $x patofyziologie $7 D006325
650    _2
$a srdeční komory $x patofyziologie $7 D006352
650    _2
$a podpůrné srdeční systémy $x klasifikace $7 D006353
650    _2
$a hemodynamika $x účinky léků $x fyziologie $7 D006439
650    12
$a modely u zvířat $7 D023421
650    _2
$a noradrenalin $x farmakologie $7 D009638
650    _2
$a prasata $7 D013552
650    _2
$a výsledek terapie $7 D016896
650    _2
$a fibrilace komor $x patofyziologie $x terapie $7 D014693
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Mlček, Mikuláš $7 xx0106453
700    1#
$a Holý, František. $7 _AN045533
700    1_
$a Horáková, Svatava $7 xx0123104
700    1_
$a Královec, Štěpán, $d 1979- $7 xx0166920
700    1_
$a Skoda, Jan $u -
700    1#
$a Petrů, Jan. $7 xx0312278
700    1_
$a Kruger, Andreas $u -
700    1_
$a Hrachovina, Vladimír, $d 1951- $7 jn20000710053
700    1_
$a Svoboda, Tomáš
700    1_
$a Kittnar, Otomar, $d 1953- $7 jn20000710185
700    1_
$a Reddy, Vivek Y
700    1_
$a Neužil, Petr, $d 1962- $7 jn20010310073
773    0_
$w MED00159578 $t Circulation. Arrhythmia and electrophysiology. Arrhythmia and electrophysiology $x 1941-3084 $g Roč. 5, č. 6 (2012), s. 1202-6
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23051839 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130404 $b ABA008
991    __
$a 20130625121438 $b ABA008
999    __
$a ok $b bmc $g 975601 $s 810684
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 5 $c 6 $d 1202-6 $i 1941-3084 $m Circulation. Arrhythmia and electrophysiology $n Circ Arrhythm Electrophysiol $x MED00159578 $o Arrhythmia and electrophysiology
LZP    __
$a Pubmed-20130404

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...