Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model
P. Ostadal, M. Mlcek, F. Holy, S. Horakova, S. Kralovec, J. Skoda, J. Petru, A. Kruger, V. Hrachovina, T. Svoboda, O. Kittnar, VY. Reddy, P. Neuzil,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
NLK
Free Medical Journals
od 2008 do Před 1 rokem
Open Access Digital Library
od 2008-04-01
- MeSH
- aorta patofyziologie MeSH
- fibrilace komor patofyziologie terapie MeSH
- hemodynamika účinky léků fyziologie MeSH
- mimotělní membránová oxygenace * MeSH
- modely u zvířat * MeSH
- noradrenalin farmakologie MeSH
- podpůrné srdeční systémy klasifikace MeSH
- prasata MeSH
- srdeční komory patofyziologie MeSH
- srdeční síně patofyziologie MeSH
- výsledek terapie MeSH
- zvířata MeSH
- Check Tag
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
BACKGROUND: Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS AND RESULTS: Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. CONCLUSIONS: Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13012403
- 003
- CZ-PrNML
- 005
- 20130625121007.0
- 007
- ta
- 008
- 130404s2012 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1161/circep.112.973123 $2 doi
- 035 __
- $a (PubMed)23051839
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Ošťádal, Petr. $7 xx0036674 $u Cardiovascular Center, Na Homolce Hospital, 15030 Prague, Czech Republic. ostadal.petr@gmail.com
- 245 10
- $a Direct comparison of percutaneous circulatory support systems in specific hemodynamic conditions in a porcine model / $c P. Ostadal, M. Mlcek, F. Holy, S. Horakova, S. Kralovec, J. Skoda, J. Petru, A. Kruger, V. Hrachovina, T. Svoboda, O. Kittnar, VY. Reddy, P. Neuzil,
- 520 9_
- $a BACKGROUND: Several percutaneous circulatory support systems have been recently introduced into clinical practice for the treatment of cardiogenic shock or refractory nontolerated ventricular tachycardia, in support of high-risk catheter interventions and, occasionally, cardiopulmonary resuscitation. To date, however, a direct comparison of the available systems has not been performed. METHODS AND RESULTS: Adult female pigs (weight 50-60 kg) were used throughout the experiment. Under deep anesthesia and mechanical ventilation, 3 percutaneous circulatory support systems were compared: (1) right atrium-aorta, extracorporeal membrane oxygenation (n=4); (2) left atrium-aorta, TandemHeart system (n=4); (3) left ventricle-aorta, Impella 2.5 system (n=4), and (4) left ventricle-aorta with norepinephrine at 0.1 µg/kg per minute (n=4). Hemodynamic efficacy (mean arterial pressure) was measured at 3 specific conditions: ventricular pacing at 200 and 300 beats per minute, and ventricular fibrillation. Although no or only nonsignificant differences were found among the systems at ventricular pacing of 200 and 300 beats per minute, under ventricular fibrillation, the right atrium-aorta system was significantly the most efficacious, followed by the left atrium-aorta system and the left ventricle-aorta system (P<0.001). However, the left ventricle-aorta system with norepinephrine still maintained mean arterial pressure comparable with the left atrium-aorta system. CONCLUSIONS: Differences were seen in the hemodynamic efficacy of available percutaneous circulatory support systems, particularly under the most severe hemodynamic condition, ventricular fibrillation.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a aorta $x patofyziologie $7 D001011
- 650 12
- $a mimotělní membránová oxygenace $7 D015199
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a srdeční síně $x patofyziologie $7 D006325
- 650 _2
- $a srdeční komory $x patofyziologie $7 D006352
- 650 _2
- $a podpůrné srdeční systémy $x klasifikace $7 D006353
- 650 _2
- $a hemodynamika $x účinky léků $x fyziologie $7 D006439
- 650 12
- $a modely u zvířat $7 D023421
- 650 _2
- $a noradrenalin $x farmakologie $7 D009638
- 650 _2
- $a prasata $7 D013552
- 650 _2
- $a výsledek terapie $7 D016896
- 650 _2
- $a fibrilace komor $x patofyziologie $x terapie $7 D014693
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453
- 700 1#
- $a Holý, František. $7 _AN045533
- 700 1_
- $a Horáková, Svatava $7 xx0123104
- 700 1_
- $a Královec, Štěpán, $d 1979- $7 xx0166920
- 700 1_
- $a Skoda, Jan $u -
- 700 1#
- $a Petrů, Jan. $7 xx0312278
- 700 1_
- $a Kruger, Andreas $u -
- 700 1_
- $a Hrachovina, Vladimír, $d 1951- $7 jn20000710053
- 700 1_
- $a Svoboda, Tomáš
- 700 1_
- $a Kittnar, Otomar, $d 1953- $7 jn20000710185
- 700 1_
- $a Reddy, Vivek Y
- 700 1_
- $a Neužil, Petr, $d 1962- $7 jn20010310073
- 773 0_
- $w MED00159578 $t Circulation. Arrhythmia and electrophysiology. Arrhythmia and electrophysiology $x 1941-3084 $g Roč. 5, č. 6 (2012), s. 1202-6
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23051839 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130404 $b ABA008
- 991 __
- $a 20130625121438 $b ABA008
- 999 __
- $a ok $b bmc $g 975601 $s 810684
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 5 $c 6 $d 1202-6 $i 1941-3084 $m Circulation. Arrhythmia and electrophysiology $n Circ Arrhythm Electrophysiol $x MED00159578 $o Arrhythmia and electrophysiology
- LZP __
- $a Pubmed-20130404