• Je něco špatně v tomto záznamu ?

Evaluation of new mixed-mode UHPLC stationary phases and the importance of stationary phase choice when using low ionic-strength mobile phase additives

L. Nováková, H. Vlčková, S. Petr,

. 2012 ; 93 () : 99-105.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13016155

In this study, the selectivity, retention properties, peak shape and loading capacity for bases were practically evaluated using two UHPLC mixed-mode hybrid CSH stationary phases modified by C18 or Phenyl group. The data were compared with the data obtained on other UHPLC hybrid stationary phases (BEH C18, BEH C8, BEH Phenyl and BEH Shield RP18) at both basic and acidic conditions using conventional HPLC buffers (50mM ammonium formate/acetate) as well as low ionic-strength additives such as, e.g. 0.1-0.01% formic/acetic acid and 1mM solution of ammonium formate/acetate, which are widely used in LC-MS applications. Ten pharmaceutically important compounds encompassing acids, bases and neutral were included into the study. Due to properties of CSH sorbent (which possess positively charged surface besides RP group), much improved peak shapes and weaker retention was obtained for bases even at very low concentration of acidic additives. Such conditions are ideally suited for LC-MS analysis of bases, where typical RP chromatographic separation (retention and good selectivity at basic pH) and LS-MS conditions (efficient ionization at acidic pH) are not in agreement. On the other hand, acids were more strongly retained and for some compounds the peak shape was influenced negatively due to ion-exchange mechanism. Further, the behavior of acidic, basic and neutral solutes is discussed using various additives at both basic and acidic pH for all above stated columns. The robustness of retention times after pH change from basic to acidic was also evaluated. The new CSH stationary phases represent an interesting selectivity tool preferably for separation of basic compounds.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13016155
003      
CZ-PrNML
005      
20130424134931.0
007      
ta
008      
130424s2012 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2012.01.054 $2 doi
035    __
$a (PubMed)22483883
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Nováková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. nol@email.cz
245    10
$a Evaluation of new mixed-mode UHPLC stationary phases and the importance of stationary phase choice when using low ionic-strength mobile phase additives / $c L. Nováková, H. Vlčková, S. Petr,
520    9_
$a In this study, the selectivity, retention properties, peak shape and loading capacity for bases were practically evaluated using two UHPLC mixed-mode hybrid CSH stationary phases modified by C18 or Phenyl group. The data were compared with the data obtained on other UHPLC hybrid stationary phases (BEH C18, BEH C8, BEH Phenyl and BEH Shield RP18) at both basic and acidic conditions using conventional HPLC buffers (50mM ammonium formate/acetate) as well as low ionic-strength additives such as, e.g. 0.1-0.01% formic/acetic acid and 1mM solution of ammonium formate/acetate, which are widely used in LC-MS applications. Ten pharmaceutically important compounds encompassing acids, bases and neutral were included into the study. Due to properties of CSH sorbent (which possess positively charged surface besides RP group), much improved peak shapes and weaker retention was obtained for bases even at very low concentration of acidic additives. Such conditions are ideally suited for LC-MS analysis of bases, where typical RP chromatographic separation (retention and good selectivity at basic pH) and LS-MS conditions (efficient ionization at acidic pH) are not in agreement. On the other hand, acids were more strongly retained and for some compounds the peak shape was influenced negatively due to ion-exchange mechanism. Further, the behavior of acidic, basic and neutral solutes is discussed using various additives at both basic and acidic pH for all above stated columns. The robustness of retention times after pH change from basic to acidic was also evaluated. The new CSH stationary phases represent an interesting selectivity tool preferably for separation of basic compounds.
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Vlčková, Hana $u -
700    1_
$a Petr, Solich $u -
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 93(2012), s. 99-105
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22483883 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130424 $b ABA008
991    __
$a 20130424135218 $b ABA008
999    __
$a ind $b bmc $g 979356 $s 814476
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 93 $d 99-105 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20130424

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...