Evaluation of new mixed-mode UHPLC stationary phases and the importance of stationary phase choice when using low ionic-strength mobile phase additives
L. Nováková, H. Vlčková, S. Petr,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
In this study, the selectivity, retention properties, peak shape and loading capacity for bases were practically evaluated using two UHPLC mixed-mode hybrid CSH stationary phases modified by C18 or Phenyl group. The data were compared with the data obtained on other UHPLC hybrid stationary phases (BEH C18, BEH C8, BEH Phenyl and BEH Shield RP18) at both basic and acidic conditions using conventional HPLC buffers (50mM ammonium formate/acetate) as well as low ionic-strength additives such as, e.g. 0.1-0.01% formic/acetic acid and 1mM solution of ammonium formate/acetate, which are widely used in LC-MS applications. Ten pharmaceutically important compounds encompassing acids, bases and neutral were included into the study. Due to properties of CSH sorbent (which possess positively charged surface besides RP group), much improved peak shapes and weaker retention was obtained for bases even at very low concentration of acidic additives. Such conditions are ideally suited for LC-MS analysis of bases, where typical RP chromatographic separation (retention and good selectivity at basic pH) and LS-MS conditions (efficient ionization at acidic pH) are not in agreement. On the other hand, acids were more strongly retained and for some compounds the peak shape was influenced negatively due to ion-exchange mechanism. Further, the behavior of acidic, basic and neutral solutes is discussed using various additives at both basic and acidic pH for all above stated columns. The robustness of retention times after pH change from basic to acidic was also evaluated. The new CSH stationary phases represent an interesting selectivity tool preferably for separation of basic compounds.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13016155
- 003
- CZ-PrNML
- 005
- 20130424134931.0
- 007
- ta
- 008
- 130424s2012 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2012.01.054 $2 doi
- 035 __
- $a (PubMed)22483883
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Nováková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. nol@email.cz
- 245 10
- $a Evaluation of new mixed-mode UHPLC stationary phases and the importance of stationary phase choice when using low ionic-strength mobile phase additives / $c L. Nováková, H. Vlčková, S. Petr,
- 520 9_
- $a In this study, the selectivity, retention properties, peak shape and loading capacity for bases were practically evaluated using two UHPLC mixed-mode hybrid CSH stationary phases modified by C18 or Phenyl group. The data were compared with the data obtained on other UHPLC hybrid stationary phases (BEH C18, BEH C8, BEH Phenyl and BEH Shield RP18) at both basic and acidic conditions using conventional HPLC buffers (50mM ammonium formate/acetate) as well as low ionic-strength additives such as, e.g. 0.1-0.01% formic/acetic acid and 1mM solution of ammonium formate/acetate, which are widely used in LC-MS applications. Ten pharmaceutically important compounds encompassing acids, bases and neutral were included into the study. Due to properties of CSH sorbent (which possess positively charged surface besides RP group), much improved peak shapes and weaker retention was obtained for bases even at very low concentration of acidic additives. Such conditions are ideally suited for LC-MS analysis of bases, where typical RP chromatographic separation (retention and good selectivity at basic pH) and LS-MS conditions (efficient ionization at acidic pH) are not in agreement. On the other hand, acids were more strongly retained and for some compounds the peak shape was influenced negatively due to ion-exchange mechanism. Further, the behavior of acidic, basic and neutral solutes is discussed using various additives at both basic and acidic pH for all above stated columns. The robustness of retention times after pH change from basic to acidic was also evaluated. The new CSH stationary phases represent an interesting selectivity tool preferably for separation of basic compounds.
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vlčková, Hana $u -
- 700 1_
- $a Petr, Solich $u -
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 93(2012), s. 99-105
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22483883 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130424 $b ABA008
- 991 __
- $a 20130424135218 $b ABA008
- 999 __
- $a ind $b bmc $g 979356 $s 814476
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 93 $d 99-105 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20130424