-
Je něco špatně v tomto záznamu ?
Automated detection of organophosphate warfare gases (nerve agents) in air based on micro-SIA - lab-on-valve system
Ondřej Pavlíček, Miroslav Polášek, Martin Foltýn, Jiří Cabal
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem, hodnotící studie
NLK
Free Medical Journals
od 2003 do 2013
Freely Accessible Science Journals
od 2003 do 2013
ROAD: Directory of Open Access Scholarly Resources
od 2002
- MeSH
- butyrylcholinesterasa MeSH
- chemické bojové látky MeSH
- cholinesterasové inhibitory analýza MeSH
- design vybavení MeSH
- laboratorní automatizace přístrojové vybavení MeSH
- organofosforové sloučeniny analýza MeSH
- průtoková injekční analýza * metody přístrojové vybavení statistika a číselné údaje MeSH
- sarin * analýza MeSH
- sekvenční analýza metody MeSH
- spektrofotometrie metody MeSH
- zdravotnické prostředky MeSH
- znečištění ovzduší * analýza statistika a číselné údaje MeSH
- Publikační typ
- hodnotící studie MeSH
- práce podpořená grantem MeSH
Equipment for fast and accurate detection of organophosphate nerve agents is developed and tested. The method is based on the spectrophotometric monitoring of the enzyme activity of butyrylcholinesterase after its contact with air in a special absorption unit (a “scrubber”) developed for the purpose. The scrubber was made from a glass tube filled with glass beads (diam. 3 mm) and filled with approx. 5 ml of butyrylcholinesterase in a phosphate buffer of pH 7.4. The air sample was bubbled through this solution for 20 s at a flow rate of 80 l hour-1. Thereafter 8 microl of the enzyme solution were aspirated into the micro-SIA-LOV analyzer and the activity of the enzymes were evaluated by using Ellman’s reagent, i.e. 2.5 mmol l-1 butyrylthiocholine iodide and 0.25 mmol 5,5’-dithiobis (2-nitrobenzoic acid). The absorbance of the coloured reaction product was measured at 412 nm after the reaction time of 60 s. The residue of the absorption liquid was washed away from the absorber and the system was washed with the enzyme solution prior to next analysis. The contaminated air caused partial inhibition of the enzyme activity of the absorption liquid. The activity of the contaminated sample was compared with the activity of the unaffected enzyme (blank measurement). The analysis was controlled by two PCs. The effect of the concentration of analyte in the absorption liquid on the enzyme activity was tested for 10-5-10-9 mol l-1 sarin. A single analysis (including the absorption step) took <130 s.
Citace poskytuje Crossref.org
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13018645
- 003
- CZ-PrNML
- 005
- 20130913130909.0
- 007
- ta
- 008
- 130516s2013 xr d f 000 0eng||
- 009
- AR
- 024 7_
- $a 10.2478/v10136-012-0016-9 $2 doi
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Pavlíček, Ondřej $7 xx0136672 $u Faculty of Pharmacy, Charles University, Hradec Králové
- 245 10
- $a Automated detection of organophosphate warfare gases (nerve agents) in air based on micro-SIA - lab-on-valve system / $c Ondřej Pavlíček, Miroslav Polášek, Martin Foltýn, Jiří Cabal
- 504 __
- $a Literatura
- 520 3_
- $a Equipment for fast and accurate detection of organophosphate nerve agents is developed and tested. The method is based on the spectrophotometric monitoring of the enzyme activity of butyrylcholinesterase after its contact with air in a special absorption unit (a “scrubber”) developed for the purpose. The scrubber was made from a glass tube filled with glass beads (diam. 3 mm) and filled with approx. 5 ml of butyrylcholinesterase in a phosphate buffer of pH 7.4. The air sample was bubbled through this solution for 20 s at a flow rate of 80 l hour-1. Thereafter 8 microl of the enzyme solution were aspirated into the micro-SIA-LOV analyzer and the activity of the enzymes were evaluated by using Ellman’s reagent, i.e. 2.5 mmol l-1 butyrylthiocholine iodide and 0.25 mmol 5,5’-dithiobis (2-nitrobenzoic acid). The absorbance of the coloured reaction product was measured at 412 nm after the reaction time of 60 s. The residue of the absorption liquid was washed away from the absorber and the system was washed with the enzyme solution prior to next analysis. The contaminated air caused partial inhibition of the enzyme activity of the absorption liquid. The activity of the contaminated sample was compared with the activity of the unaffected enzyme (blank measurement). The analysis was controlled by two PCs. The effect of the concentration of analyte in the absorption liquid on the enzyme activity was tested for 10-5-10-9 mol l-1 sarin. A single analysis (including the absorption step) took <130 s.
- 650 _2
- $a chemické bojové látky $7 D002619
- 650 _2
- $a organofosforové sloučeniny $x analýza $7 D009943
- 650 _2
- $a cholinesterasové inhibitory $x analýza $7 D002800
- 650 12
- $a sarin $x analýza $7 D012524
- 650 _2
- $a butyrylcholinesterasa $7 D002091
- 650 _2
- $a spektrofotometrie $x metody $7 D013053
- 650 _2
- $a zdravotnické prostředky $7 D004864
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a laboratorní automatizace $x přístrojové vybavení $7 D057205
- 650 12
- $a průtoková injekční analýza $x metody $x přístrojové vybavení $x statistika a číselné údaje $7 D017022
- 650 _2
- $a sekvenční analýza $x metody $7 D017421
- 650 12
- $a znečištění ovzduší $x analýza $x statistika a číselné údaje $7 D000397
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a hodnotící studie $7 D023362
- 700 1_
- $a Polášek, Miroslav, $d 1947- $7 xx0063895 $u Faculty of Pharmacy, Charles University, Hradec Králové
- 700 1_
- $a Foltýn, Martin. $7 _AN072980 $u Faculty of Pharmacy, Charles University, Hradec Králové
- 700 1_
- $a Cabal, Jiří, $d 1957- $7 mzk2003181397 $u Faculty of Military Health Sciences, University of Defense, Hradec Králové
- 773 0_
- $t Journal of applied biomedicine $x 1214-021X $g Roč. 11, č. 1 (2013), s. 27-32 $w MED00012667
- 856 41
- $u https://jab.zsf.jcu.cz/pdfs/jab/2013/01/04.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 2301 $c 1249 $y 3 $z 0
- 990 __
- $a 20130516084842 $b ABA008
- 991 __
- $a 20130913131404 $b ABA008
- 999 __
- $a ok $b bmc $g 982000 $s 816983
- BAS __
- $a 3
- BMC __
- $a 2013 $b 11 $c 1 $i 1214-021X $m Journal of Applied Biomedicine $n J. Appl. Biomed. (Čes. Budějovice Print) $x MED00012667 $d 27-32
- LZP __
- $c NLK188 $d 20130913 $a NLK 2013-23/ip