-
Something wrong with this record ?
Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids
P. Chocholouš, J. Vacková, I. Srámková, D. Satínský, P. Solich,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Chromatography, Reverse-Phase * MeSH
- Hydroxybenzoates analysis MeSH
- Injections MeSH
- Calibration MeSH
- Molecular Structure MeSH
- Spectrophotometry, Ultraviolet MeSH
- Particle Size MeSH
- Chromatography, High Pressure Liquid * MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13024091
- 003
- CZ-PrNML
- 005
- 20130709093611.0
- 007
- ta
- 008
- 130703s2013 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2012.10.036 $2 doi
- 035 __
- $a (PubMed)23200381
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Chocholouš, Petr $u Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. petr.chocholous@faf.cuni.cz
- 245 10
- $a Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids / $c P. Chocholouš, J. Vacková, I. Srámková, D. Satínský, P. Solich,
- 520 9_
- $a Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold.
- 650 _2
- $a kalibrace $7 D002138
- 650 12
- $a vysokoúčinná kapalinová chromatografie $7 D002851
- 650 12
- $a chromatografie s reverzní fází $7 D056148
- 650 _2
- $a hydroxybenzoáty $x analýza $7 D062385
- 650 _2
- $a injekce $7 D007267
- 650 _2
- $a molekulární struktura $7 D015394
- 650 _2
- $a velikost částic $7 D010316
- 650 _2
- $a spektrofotometrie ultrafialová $7 D013056
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vacková, Jana $u -
- 700 1_
- $a Srámková, Ivana $u -
- 700 1_
- $a Satínský, Dalibor $u -
- 700 1_
- $a Solich, Petr $u -
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 103(2013), s. 221-7
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23200381 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130703 $b ABA008
- 991 __
- $a 20130709094033 $b ABA008
- 999 __
- $a ok $b bmc $g 987771 $s 822471
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 103 $d 221-7 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20130703