• Something wrong with this record ?

Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids

P. Chocholouš, J. Vacková, I. Srámková, D. Satínský, P. Solich,

. 2013 ; 103 () : 221-7.

Language English Country Netherlands

Document type Journal Article, Research Support, Non-U.S. Gov't

Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13024091
003      
CZ-PrNML
005      
20130709093611.0
007      
ta
008      
130703s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2012.10.036 $2 doi
035    __
$a (PubMed)23200381
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Chocholouš, Petr $u Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Department of Analytical Chemistry, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. petr.chocholous@faf.cuni.cz
245    10
$a Advantages of core-shell particle columns in Sequential Injection Chromatography for determination of phenolic acids / $c P. Chocholouš, J. Vacková, I. Srámková, D. Satínský, P. Solich,
520    9_
$a Currently, for Sequential Injection Chromatography (SIC), only reversed phase C18 columns have been used for chromatographic separations. This article presents the first use of three different stationary phases: three core-shell particle-packed reversed phase columns in flow systems. The aim of this work was to extend the chromatographic capabilities of the SIC system. Despite the particle-packed columns reaching system pressures of ≤ 610 PSI, their conditions matched those of a commercially produced and optimised SIC system (SIChrom™ (FIAlab(®), USA)) with a 8-port high-pressure selection valve and medium-pressure Sapphire™ syringe pump with a 4 mL reservoir and maximum system pressure of ≤ 1000 PSI. The selectivity of each of the tested columns, Ascentis(®) Express RP-Amide, Ascentis(®) Express Phenyl-Hexyl and Ascentis(®) Express C18 (30 mm × 4.6mm, core-shell particle size 2.7 μm), was compared by their ability to separate seven phenolic acids that are secondary metabolite substances widely distributed in plants. The separations of all of the components were performed by isocratic elution using binary mobile phases composed of acetonitrile and 0.065% phosphoric acid at pH 2.4 (a specific ratio was used for each column) at a flow-rate of 0.60 mL/min. The volume of the mobile phase was 3.8 mL for each separation. The injection volume of the sample was 10 μL for each separation. The UV detection wavelengths were set to 250, 280 and 325 nm. The RP-Amide column provided the highest chromatographic resolution and allowed for complete baseline separation of protocatechuic, syringic, vanillic, ferulic, sinapinic, p-coumaric and o-coumaric acids. The Phenyl-Hexyl and C18 columns were unable to completely separate the tested mixture, syringic and vanillic acid and ferulic and sinapinic acids could not be separated from one another. The analytical parameters were a LOD of 0.3 mg L(-1), a LOQ of 1.0 mg L(-1), a calibration range of 1.0-50.0 (100.0) mg L(-1) (r>0.997) and a system precision of 10 mg L(-1) with a RSD ≤ 1.65%. The high performance of the chromatography process with the RP-Amide column under optimised conditions was highlighted and well documented (HETP values ≤ 10 μm, peak symmetry ≤ 1.33, resolution ≥ 1.87 and time for one analysis <8.0 min). The results of these experiments confirmed the benefits of extending chromatographic selectivity using core-shell particle column technology in a SIC manifold.
650    _2
$a kalibrace $7 D002138
650    12
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    12
$a chromatografie s reverzní fází $7 D056148
650    _2
$a hydroxybenzoáty $x analýza $7 D062385
650    _2
$a injekce $7 D007267
650    _2
$a molekulární struktura $7 D015394
650    _2
$a velikost částic $7 D010316
650    _2
$a spektrofotometrie ultrafialová $7 D013056
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Vacková, Jana $u -
700    1_
$a Srámková, Ivana $u -
700    1_
$a Satínský, Dalibor $u -
700    1_
$a Solich, Petr $u -
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 103(2013), s. 221-7
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23200381 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130703 $b ABA008
991    __
$a 20130709094033 $b ABA008
999    __
$a ok $b bmc $g 987771 $s 822471
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 103 $d 221-7 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20130703

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...