Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Voltammetry as a Tool for Characterization of CdTe Quantum Dots

P. Sobrova, M. Ryvolova, J. Hubalek, V. Adam, R. Kizek,

. 2013 ; 14 (7) : 13497-510.

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13024502

Electrochemical detection of quantum dots (QDs) has already been used in numerous applications. However, QDs have not been well characterized using voltammetry, with respect to their characterization and quantification. Therefore, the main aim was to characterize CdTe QDs using cyclic and differential pulse voltammetry. The obtained peaks were identified and the detection limit (3 S/N) was estimated down to 100 fg/mL. Based on the convincing results, a new method for how to study stability and quantify the dots was suggested. Thus, the approach was further utilized for the testing of QDs stability.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13024502
003      
CZ-PrNML
005      
20130710125255.0
007      
ta
008      
130703s2013 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/ijms140713497 $2 doi
035    __
$a (PubMed)23807507
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Sobrova, Pavlina $u Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic. hubalek@feec.vutbr.cz.
245    10
$a Voltammetry as a Tool for Characterization of CdTe Quantum Dots / $c P. Sobrova, M. Ryvolova, J. Hubalek, V. Adam, R. Kizek,
520    9_
$a Electrochemical detection of quantum dots (QDs) has already been used in numerous applications. However, QDs have not been well characterized using voltammetry, with respect to their characterization and quantification. Therefore, the main aim was to characterize CdTe QDs using cyclic and differential pulse voltammetry. The obtained peaks were identified and the detection limit (3 S/N) was estimated down to 100 fg/mL. Based on the convincing results, a new method for how to study stability and quantify the dots was suggested. Thus, the approach was further utilized for the testing of QDs stability.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Ryvolova, Marketa $u -
700    1_
$a Hubalek, Jaromir $u -
700    1_
$a Adam, Vojtěch $u - $7 xx0064599
700    1_
$a Kizek, Rene $u -
773    0_
$w MED00176142 $t International journal of molecular sciences $x 1422-0067 $g Roč. 14, č. 7 (2013), s. 13497-510
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23807507 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130703 $b ABA008
991    __
$a 20130710125719 $b ABA008
999    __
$a ind $b bmc $g 988182 $s 822882
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 14 $c 7 $d 13497-510 $i 1422-0067 $m International journal of molecular sciences $n Int J Mol Sci $x MED00176142
LZP    __
$a Pubmed-20130703

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...