Optimization and validation of a high performance liquid chromatography method for the simultaneous determination of vitamins A and E in human serum using monolithic column and diode-array detection

Urbánek L, Solichová D, Melichar B, Dvorák J, Svobodová I, Solich P.

. 2006 ; 573-574 () : 267-272.

Jazyk angličtina Země Nizozemsko

Perzistentní odkaz   https://www.medvik.cz/link/bmc13027144

Grantová podpora
NR8048 MZ0 CEP - Centrální evidence projektů

In this study a novel, simple and rapid reversed-phase high performance liquid chromatography (HPLC) procedure for simultaneous determination of vitamins A and E (retinol and alpha-tocopherol) in blood serum has been developed and validated using monolithic column and diode-array detection (DAD). The monolithic column Chromolith Performance RP-18e (100 mm x 4.6 mm) was operated at ambient temperature. One hundred percent methanol at flow rate 2.5 ml min(-1) was used as a mobile phase. Detection of both compounds was performed with diode-array detector, retinol was monitored at 325 nm and alpha-tocopherol at 295 nm. The linear dependence between peak area and concentration ranged from 0.25 to 10.00 micromol l(-1) for retinol and 0.5-50.0 micromol l(-1) for alpha-tocopherol. The limit of detection (LOD) for retinol was 0.02 micromol l(-1) and limit of quantification (LOQ) was 0.07 micromol l(-1). The limit of detection (LOD) for alpha-tocopherol was 0.1 micromol l(-1) and limit of quantification (LOQ) was 0.3 micromol l(-1). Retinol was eluted in 0.8 min and alpha-tocopherol in 1.4 min. The simultaneous analysis of vitamin A and E can be achieved in less than 2 min. The implementation of monolithic column Chromolith Performance shortens the time of analysis of both vitamins four times in comparison with using traditional particulate column Pecosphere C18 (150 mm x 4.6 mm), 5 microm. This fact may play an important role for routine clinical analysis of biological samples

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13027144
003      
CZ-PrNML
005      
20130903132712.0
007      
ta
008      
130819s2006 ne f 000 0eng||
009      
AR
024    7_
$a 10.1016/j.aca.2006.02.032 $2 doi
035    __
$a (PubMed)17723533
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Urbánek, Lubor $7 xx0100212 $u Charles University in Prague, Department of Analytical Chemistry, Faculty of Pharmacy, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic; Charles University in Prague, Faculty of Medicine and University Hospital in Hradec Králové, Department of Metabolic Care and Gerontology,Hradec Králové, Czech Republic
245    10
$a Optimization and validation of a high performance liquid chromatography method for the simultaneous determination of vitamins A and E in human serum using monolithic column and diode-array detection / $c Urbánek L, Solichová D, Melichar B, Dvorák J, Svobodová I, Solich P.
520    9_
$a In this study a novel, simple and rapid reversed-phase high performance liquid chromatography (HPLC) procedure for simultaneous determination of vitamins A and E (retinol and alpha-tocopherol) in blood serum has been developed and validated using monolithic column and diode-array detection (DAD). The monolithic column Chromolith Performance RP-18e (100 mm x 4.6 mm) was operated at ambient temperature. One hundred percent methanol at flow rate 2.5 ml min(-1) was used as a mobile phase. Detection of both compounds was performed with diode-array detector, retinol was monitored at 325 nm and alpha-tocopherol at 295 nm. The linear dependence between peak area and concentration ranged from 0.25 to 10.00 micromol l(-1) for retinol and 0.5-50.0 micromol l(-1) for alpha-tocopherol. The limit of detection (LOD) for retinol was 0.02 micromol l(-1) and limit of quantification (LOQ) was 0.07 micromol l(-1). The limit of detection (LOD) for alpha-tocopherol was 0.1 micromol l(-1) and limit of quantification (LOQ) was 0.3 micromol l(-1). Retinol was eluted in 0.8 min and alpha-tocopherol in 1.4 min. The simultaneous analysis of vitamin A and E can be achieved in less than 2 min. The implementation of monolithic column Chromolith Performance shortens the time of analysis of both vitamins four times in comparison with using traditional particulate column Pecosphere C18 (150 mm x 4.6 mm), 5 microm. This fact may play an important role for routine clinical analysis of biological samples
650    _2
$a chromatografie kapalinová $7 D002853
650    _2
$a alfa-tokoferol $7 D024502
650    _2
$a vitamin A $7 D014801
650    _2
$a vitamin E $7 D014810
650    _2
$a sérum $7 D044967
700    1_
$a Solichová, Dagmar $7 xx0060526 $u Charles University in Prague, Faculty of Medicine and University Hospital in Hradec Králové, Department of Metabolic Care and Gerontology,Hradec Králové, Czech Republic
700    1_
$a Melichar, Bohuslav, $d 1965- $7 skuk0000853 $u Charles University in Prague, Faculty of Medicine and University Hospital in Hradec Králové, Department of Oncology and Radiotherapy,Hradec Králové, Czech Republic
700    1_
$a Dvořák, Josef, $d 1966- $7 xx0072583 $u Charles University in Prague, Faculty of Medicine and University Hospital in Hradec Králové, Department of Oncology and Radiotherapy,Hradec Králové, Czech Republic
700    1_
$a Svobodová, Iveta $7 xx0119408 $u Charles University in Prague, Faculty of Medicine and University Hospital in Hradec Králové, Department of Metabolic Care and Gerontology,Hradec Králové, Czech Republic
700    1_
$a Solich, Petr, $d 1955- $7 jo2007285395 $u Charles University in Prague, Department of Analytical Chemistry, Faculty of Pharmacy, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic
773    0_
$t Analytica chimica acta $x 0003-2670 $g Roč. 573-574(2006), s. 267-272 $w MED00000332
910    __
$a ABA008 $y 3 $z 0
990    __
$a 20130819144106 $b ABA008
991    __
$a 20130903133159 $b ABA008
999    __
$a ok $b bmc $g 991026 $s 825570
BAS    __
$a 3
BMC    __
$x MED00000332 $i 0003-2670 $a 2006 $b 573-574 $d 267-272 $m Analytica chimica acta $n Anal. chim. acta (Print)
GRA    __
$a NR8048 $p MZ0
LZP    __
$c NLK115 $d 20130903 $a NLK 2013-08/lp

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...