A prototype 'Infucon' device for continuous infusion of microbubbles in vivo
Z. Kauerová, R. Lukáč, P. Kohout, J. Mašek, Š. Koudelka, J. Plocková, M. Vašíčková, M. Vlašín, J. Turánek,
Language English Country Netherlands
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- 1,2-Dipalmitoylphosphatidylcholine chemistry MeSH
- Time Factors MeSH
- Sulfur Hexafluoride diagnostic use MeSH
- Phospholipids diagnostic use MeSH
- Infusions, Intravenous MeSH
- Rabbits MeSH
- Microbubbles diagnostic use MeSH
- Polyethylene Glycols chemistry MeSH
- Ultrasonography methods MeSH
- Animals MeSH
- Check Tag
- Rabbits MeSH
- Male MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
A device for continuous infusion of microbubbles (MBs) 'Infucon' has been designed, constructed and tested on rabbits. The device prevents MBs from flotation and accumulation in the layer directly below the surface in the syringe injection during i.v. application. Homogenous i.v. application of MBs was tested on 16 male New Zealand White rabbits (average weight about 3.5 kg). Two sorts of MBs were used - a set of commercial SonoVue diagnostic microbubbles (Bracco) and pegylated DPPC microbubbles (PegMBs), which had been prepared in our laboratory. Sulphur hexafluoride was used as a filling gas. The application of MBs by continuous infusion via Infucon prolonged the ultrasound signal period in the heart of the rabbit to 12 min in comparison to about 1 min observed in bolus application. No adverse effects were observed on the tested rabbits after the MB application via Infucon. The principle employed in the prototype device Infucon could be used for development of the device intended for clinical applications.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13031749
- 003
- CZ-PrNML
- 005
- 20221014085517.0
- 007
- ta
- 008
- 131002s2013 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ijpharm.2012.12.026 $2 doi
- 035 __
- $a (PubMed)23266760
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Horáčková, Zuzana $u Department of Pharmacology, Toxicology and Immunotherapy, Veterinary Research Institute, Hudcova 10, 621 00 Brno, Czech Republic. zuzana.kauerova@gmail.com $7 xx0277553
- 245 12
- $a A prototype 'Infucon' device for continuous infusion of microbubbles in vivo / $c Z. Kauerová, R. Lukáč, P. Kohout, J. Mašek, Š. Koudelka, J. Plocková, M. Vašíčková, M. Vlašín, J. Turánek,
- 520 9_
- $a A device for continuous infusion of microbubbles (MBs) 'Infucon' has been designed, constructed and tested on rabbits. The device prevents MBs from flotation and accumulation in the layer directly below the surface in the syringe injection during i.v. application. Homogenous i.v. application of MBs was tested on 16 male New Zealand White rabbits (average weight about 3.5 kg). Two sorts of MBs were used - a set of commercial SonoVue diagnostic microbubbles (Bracco) and pegylated DPPC microbubbles (PegMBs), which had been prepared in our laboratory. Sulphur hexafluoride was used as a filling gas. The application of MBs by continuous infusion via Infucon prolonged the ultrasound signal period in the heart of the rabbit to 12 min in comparison to about 1 min observed in bolus application. No adverse effects were observed on the tested rabbits after the MB application via Infucon. The principle employed in the prototype device Infucon could be used for development of the device intended for clinical applications.
- 650 _2
- $a 1,2-dipalmitoylfosfatidylcholin $x chemie $7 D015060
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a intravenózní infuze $7 D007262
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a mikrobubliny $x diagnostické užití $7 D045423
- 650 _2
- $a fosfolipidy $x diagnostické užití $7 D010743
- 650 _2
- $a polyethylenglykoly $x chemie $7 D011092
- 650 _2
- $a králíci $7 D011817
- 650 _2
- $a fluorid sírový $x diagnostické užití $7 D013459
- 650 _2
- $a časové faktory $7 D013997
- 650 _2
- $a ultrasonografie $x metody $7 D014463
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Lukáč, Róbert $u -
- 700 1_
- $a Kohout, Pavel $u -
- 700 1_
- $a Mašek, Josef $u -
- 700 1_
- $a Koudelka, Štěpán $u -
- 700 1_
- $a Plocková, Jana $u -
- 700 1_
- $a Vašíčková, Marta $u -
- 700 1_
- $a Vlašín, Michal $u -
- 700 1_
- $a Turánek, Jaroslav $u -
- 773 0_
- $w MED00002359 $t International journal of pharmaceutics $x 1873-3476 $g Roč. 441, č. 1-2 (2013), s. 92-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23266760 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20131002 $b ABA008
- 991 __
- $a 20221014085510 $b ABA008
- 999 __
- $a ok $b bmc $g 995836 $s 830194
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 441 $c 1-2 $d 92-8 $i 1873-3476 $m International journal of pharmaceutics $n Int. j. pharm. $x MED00002359
- LZP __
- $a Pubmed-20131002