• Je něco špatně v tomto záznamu ?

Luminescent sensor for carbonate ion based on lanthanide(III) complexes of 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (DO3A)

J. Vaněk, P. Lubal, P. Hermann, P. Anzenbacher,

. 2013 ; 23 (1) : 57-69.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13031892

Lanthanide(III) complexes of 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) are suggested as sensors for sensitive luminescence-based determination of a carbonate anion. Thermodynamic study of association of [Eu(H(2)O)(2)(DO3A)] with bidentate anionic ligands using luminescence spectroscopy reveals an affinity order CO(3)(2-) > oxalate(2-) > picolinate(-) > phthalate(2-) ≈ citrate(3-); presumably as a consequence of an increasing chelate ring size. The ternary [Eu(DO3A)(picolinate)](-) and [Tb(DO3A)(picolinate)](-) complexes show improved photophysical properties due to the antenna effect of the picolinate anion. High quenching effect of carbonate anion and, to a lesser extent also oxalate, enables construction of a linear calibration plot utilizing optimized experimental conditions (e.g. c(LnL) = 0.1 mM, c(picolinate) = 2-5 mM, pH = 7.4, λ(exc) = 286 nm, etc.) for carbonate determination in solution. Both sensors show a comparable sensitivity and the detection limit of about 0.4 mM. In order to improve the photophysical properties of Ln(III) sensor by shift of excitation wavelength about 40 nm to VIS range, the isoquinoline-3-carboxylic acid (IQCA) as antenna ligand was employed instead of picolinic acid. The analysis of commercial samples of European mineral waters was carried out and they were compared to the results obtained by capillary isotachophoresis to confirm there is no inherent (systematic) error to the present analysis. The Ln(III) sensor with IQCA is recommended since it has a better robustness than that with picolinate. The present analytical method is simple and rapid, and it is useful for sensitive determination of bicarbonate/carbonate concentration in water samples under aerobic conditions.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13031892
003      
CZ-PrNML
005      
20180214201939.0
007      
ta
008      
131002s2013 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s10895-012-1116-3 $2 doi
035    __
$a (PubMed)22872436
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Vaněk, Jakub $u Department of Chemistry, Faculty of Science, Masaryk University, Kotlářská 2, 611 37 Brno, Czech Republic.
245    10
$a Luminescent sensor for carbonate ion based on lanthanide(III) complexes of 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (DO3A) / $c J. Vaněk, P. Lubal, P. Hermann, P. Anzenbacher,
520    9_
$a Lanthanide(III) complexes of 1,4,7,10-tetraazacyclododecane-1,4,7-triacetic acid (H(3)DO3A) are suggested as sensors for sensitive luminescence-based determination of a carbonate anion. Thermodynamic study of association of [Eu(H(2)O)(2)(DO3A)] with bidentate anionic ligands using luminescence spectroscopy reveals an affinity order CO(3)(2-) > oxalate(2-) > picolinate(-) > phthalate(2-) ≈ citrate(3-); presumably as a consequence of an increasing chelate ring size. The ternary [Eu(DO3A)(picolinate)](-) and [Tb(DO3A)(picolinate)](-) complexes show improved photophysical properties due to the antenna effect of the picolinate anion. High quenching effect of carbonate anion and, to a lesser extent also oxalate, enables construction of a linear calibration plot utilizing optimized experimental conditions (e.g. c(LnL) = 0.1 mM, c(picolinate) = 2-5 mM, pH = 7.4, λ(exc) = 286 nm, etc.) for carbonate determination in solution. Both sensors show a comparable sensitivity and the detection limit of about 0.4 mM. In order to improve the photophysical properties of Ln(III) sensor by shift of excitation wavelength about 40 nm to VIS range, the isoquinoline-3-carboxylic acid (IQCA) as antenna ligand was employed instead of picolinic acid. The analysis of commercial samples of European mineral waters was carried out and they were compared to the results obtained by capillary isotachophoresis to confirm there is no inherent (systematic) error to the present analysis. The Ln(III) sensor with IQCA is recommended since it has a better robustness than that with picolinate. The present analytical method is simple and rapid, and it is useful for sensitive determination of bicarbonate/carbonate concentration in water samples under aerobic conditions.
650    _2
$a uhličitany $x analýza $x chemie $7 D002254
650    _2
$a chemické techniky analytické $x přístrojové vybavení $7 D002623
650    _2
$a europium $x chemie $7 D005063
650    _2
$a heterocyklické sloučeniny monocyklické $x chemie $7 D006573
650    _2
$a ligandy $7 D008024
650    _2
$a luminiscenční měření $7 D008163
650    _2
$a makrocyklické sloučeniny $x chemie $7 D047028
650    _2
$a organokovové sloučeniny $x chemie $7 D009942
650    _2
$a terbium $x chemie $7 D013725
650    _2
$a termodynamika $7 D013816
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Lubal, Přemysl $u -
700    1_
$a Hermann, Petr $u -
700    1_
$a Anzenbacher, Pavel $u - $7 xx0034447 $4
773    0_
$w MED00007718 $t Journal of fluorescence $x 1573-4994 $g Roč. 23, č. 1 (2013), s. 57-69
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22872436 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20131002 $b ABA008
991    __
$a 20131007102259 $b ABA008
999    __
$a ok $b bmc $g 995979 $s 830337
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 23 $c 1 $d 57-69 $i 1573-4994 $m Journal of fluorescence $n J Fluoresc $x MED00007718
LZP    __
$a Pubmed-20131002

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace