Monitoring biventricular pacing parameters depending on the left ventricle lead configuration

A. Prochazka, D. Korpas,

. 2013 ; 18 (2) : 85-8.

Jazyk angličtina Země Kanada

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc13032623
E-zdroje Online Plný text

NLK Free Medical Journals od Jaro 2001 do Jaro 2013
PubMed Central od 2001 do 2013
Europe PubMed Central od 2001 do 2013

OBJECTIVES: To evaluate whether pacing or sensing configuration has an effect on pacing parameters or their time progression. Three left ventricular (LV) pacing parameters were monitored - the LV pacing threshold, pacing impedance and intrinsic R-wave amplitude. METHODS: DATA WERE COLLECTED AT THREE INTERVALS: during implantation; between the second and fifth month after implantation (first follow-up); and between the eighth and 15th month after implantation (second follow-up). Repeated-measures ANOVA was used for the statistical analysis. RESULTS: The impedance, but not its time progression, was significantly higher for the LV tip to LV ring configuration than for other configurations. R-wave amplitude and impedance increased significantly (without dependance on configurations) between implantation and first follow-up, as expected. The time progression of any parameter was not dependent on configuration of the LV lead. CONCLUSIONS: LV tip to LV ring is the best configuration for maintaining a high impedance level. It is better to maintain an individual approach for pacing threshold and R-wave amplitude, and their settings.

000      
00000naa a2200000 a 4500
001      
bmc13032623
003      
CZ-PrNML
005      
20131009113442.0
007      
ta
008      
131009s2013 xxc f 000 0|eng||
009      
AR
035    __
$a (PubMed)23940426
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxc
100    1_
$a Prochazka, Antonin $u Institute of Biophysics and Informatics, 1st Medical Faculty, Charles University, Prague;
245    10
$a Monitoring biventricular pacing parameters depending on the left ventricle lead configuration / $c A. Prochazka, D. Korpas,
520    9_
$a OBJECTIVES: To evaluate whether pacing or sensing configuration has an effect on pacing parameters or their time progression. Three left ventricular (LV) pacing parameters were monitored - the LV pacing threshold, pacing impedance and intrinsic R-wave amplitude. METHODS: DATA WERE COLLECTED AT THREE INTERVALS: during implantation; between the second and fifth month after implantation (first follow-up); and between the eighth and 15th month after implantation (second follow-up). Repeated-measures ANOVA was used for the statistical analysis. RESULTS: The impedance, but not its time progression, was significantly higher for the LV tip to LV ring configuration than for other configurations. R-wave amplitude and impedance increased significantly (without dependance on configurations) between implantation and first follow-up, as expected. The time progression of any parameter was not dependent on configuration of the LV lead. CONCLUSIONS: LV tip to LV ring is the best configuration for maintaining a high impedance level. It is better to maintain an individual approach for pacing threshold and R-wave amplitude, and their settings.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Korpas, David $u -
773    0_
$w MED00001735 $t Experimental and clinical cardiology $x 1205-6626 $g Roč. 18, č. 2 (2013), s. 85-8
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23940426 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20131009 $b ABA008
991    __
$a 20131009114005 $b ABA008
999    __
$a ind $b bmc $g 996792 $s 831074
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 18 $c 2 $d 85-8 $i 1205-6626 $m Experimental and clinical cardiology $n Exp. Clin. Cardiol. $x MED00001735
LZP    __
$a Pubmed-20131009

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...