Green chromatography separation of analytes of greatly differing properties using a polyethylene glycol stationary phase and a low-toxic water-based mobile phase
D. Šatínský, I. Brabcová, A. Maroušková, P. Chocholouš, P. Solich,
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 2011-01-01 to 1 year ago
- MeSH
- Acetonitriles chemistry MeSH
- Aminophenols analysis isolation & purification MeSH
- Ethylamines chemistry MeSH
- Antipyrine analogs & derivatives analysis isolation & purification MeSH
- Hydrophobic and Hydrophilic Interactions MeSH
- Calibration MeSH
- Caffeine analysis isolation & purification MeSH
- Methanol chemistry MeSH
- Acetaminophen analysis isolation & purification MeSH
- Polyethylene Glycols chemistry MeSH
- Reproducibility of Results MeSH
- Tablets analysis MeSH
- Ultraviolet Rays MeSH
- Chromatography, High Pressure Liquid instrumentation methods standards MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
A simple, rapid, and environmentally friendly HPLC method was developed and validated for the separation of four compounds (4-aminophenol, caffeine, paracetamol, and propyphenazone) with different chemical properties. A "green" mobile phase, employing water as the major eluent, was proposed and applied to the separation of analytes with different polarity on polyethylene glycol (PEG) stationary phase. The chromatography separation of all compounds and internal standard benzoic acid was performed using isocratic elution with a low-toxicity mobile phase consisting of 0.04% (v/v) triethylamine and water. HPLC separation was carried out using a PEG reversed-phase stationary phase Supelco Discovery HS PEG column (15 × 4 mm; particle size 3 μm) at a temperature of 30 °C and flow rate at 1.0 mL min(-1). The UV detector was set at 210 nm. In this study, a PEG stationary phase was shown to be suitable for the efficient isocratic separation of compounds that differ widely in hydrophobicity and acid-base properties, particularly 4-aminophenol (log P, 0.30), caffeine (log P, -0.25), and propyphenazone (log P, 2.27). A polar PEG stationary phase provided specific selectivity which allowed traditional chromatographic problems related to the separation of analytes with different polarities to be solved. The retention properties of the group of structurally similar substances (aromatic amines, phenolic compounds, and xanthine derivatives) were tested with different mobile phases. The proposed green chromatography method was successfully applied to the analysis of active substances and one degradation impurity (4-aminophenol) in commercial preparation. Under the optimum chromatographic conditions, standard calibration was carried out with good linearity correlation coefficients for all compounds in the range (0.99914-0.99997, n = 6) between the peak areas and concentration of compounds. Recovery of the sample preparation was in the range 100 ± 5% for all compounds. The intraday method precision was determined as RSD, and the values were lower than 1.00%.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14040754
- 003
- CZ-PrNML
- 005
- 20140110113823.0
- 007
- ta
- 008
- 140107s2013 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-013-7003-1 $2 doi
- 035 __
- $a (PubMed)23657456
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Šatínský, Dalibor
- 245 10
- $a Green chromatography separation of analytes of greatly differing properties using a polyethylene glycol stationary phase and a low-toxic water-based mobile phase / $c D. Šatínský, I. Brabcová, A. Maroušková, P. Chocholouš, P. Solich,
- 520 9_
- $a A simple, rapid, and environmentally friendly HPLC method was developed and validated for the separation of four compounds (4-aminophenol, caffeine, paracetamol, and propyphenazone) with different chemical properties. A "green" mobile phase, employing water as the major eluent, was proposed and applied to the separation of analytes with different polarity on polyethylene glycol (PEG) stationary phase. The chromatography separation of all compounds and internal standard benzoic acid was performed using isocratic elution with a low-toxicity mobile phase consisting of 0.04% (v/v) triethylamine and water. HPLC separation was carried out using a PEG reversed-phase stationary phase Supelco Discovery HS PEG column (15 × 4 mm; particle size 3 μm) at a temperature of 30 °C and flow rate at 1.0 mL min(-1). The UV detector was set at 210 nm. In this study, a PEG stationary phase was shown to be suitable for the efficient isocratic separation of compounds that differ widely in hydrophobicity and acid-base properties, particularly 4-aminophenol (log P, 0.30), caffeine (log P, -0.25), and propyphenazone (log P, 2.27). A polar PEG stationary phase provided specific selectivity which allowed traditional chromatographic problems related to the separation of analytes with different polarities to be solved. The retention properties of the group of structurally similar substances (aromatic amines, phenolic compounds, and xanthine derivatives) were tested with different mobile phases. The proposed green chromatography method was successfully applied to the analysis of active substances and one degradation impurity (4-aminophenol) in commercial preparation. Under the optimum chromatographic conditions, standard calibration was carried out with good linearity correlation coefficients for all compounds in the range (0.99914-0.99997, n = 6) between the peak areas and concentration of compounds. Recovery of the sample preparation was in the range 100 ± 5% for all compounds. The intraday method precision was determined as RSD, and the values were lower than 1.00%.
- 650 _2
- $a paracetamol $x analýza $x izolace a purifikace $7 D000082
- 650 _2
- $a acetonitrily $x chemie $7 D000097
- 650 _2
- $a aminofenoly $x analýza $x izolace a purifikace $7 D000627
- 650 _2
- $a fenazon $x analogy a deriváty $x analýza $x izolace a purifikace $7 D000983
- 650 _2
- $a kofein $x analýza $x izolace a purifikace $7 D002110
- 650 _2
- $a kalibrace $7 D002138
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $x normy $7 D002851
- 650 _2
- $a ethylaminy $x chemie $7 D005021
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a methanol $x chemie $7 D000432
- 650 _2
- $a polyethylenglykoly $x chemie $7 D011092
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a tablety $x analýza $7 D013607
- 650 _2
- $a ultrafialové záření $7 D014466
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Brabcová, Ivana $u -
- 700 1_
- $a Maroušková, Alena $u -
- 700 1_
- $a Chocholouš, Petr $u -
- 700 1_
- $a Solich, Petr $u -
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 405, č. 18 (2013), s. 6105-15
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23657456 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20140107 $b ABA008
- 991 __
- $a 20140110114525 $b ABA008
- 999 __
- $a ok $b bmc $g 1005150 $s 839266
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 405 $c 18 $d 6105-15 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20140107