PURPOSE: The aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts. METHODS: Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects. RESULTS: The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative T2*$$ {\mathrm{T}}_2^{\ast } $$ relaxometry analyses. CONCLUSION: Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.
- MeSH
- algoritmy * MeSH
- artefakty * MeSH
- fantomy radiodiagnostické * MeSH
- kalibrace MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- počítačové zpracování obrazu * metody MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Dual velocity encoding PC-MRI can produce spurious artifacts when using high ratios of velocity encoding values (VENCs), limiting its ability to generate high-quality images across a wide range of encoding velocities. This study aims to propose and compare dual-VENC correction methods for such artifacts. THEORY AND METHODS: Two denoising approaches based on spatiotemporal regularization are proposed and compared with a state-of-the-art method based on sign correction. Accuracy is assessed using simulated data from an aorta and brain aneurysm, as well as 8 two-dimensional (2D) PC-MRI ascending aorta datasets. Two temporal resolutions (30,60) ms and noise levels (9,12) dB are considered, with noise added to the complex magnetization. The error is evaluated with respect to the noise-free measurement in the synthetic case and to the unwrapped image without additional noise in the volunteer datasets. RESULTS: In all studied cases, the proposed methods are more accurate than the Sign Correction technique. Using simulated 2D+T data from the aorta (60 ms, 9 dB), the Dual-VENC (DV) error 0.82±0.07$$ 0.82\pm 0.07 $$ is reduced to: 0.66±0.04$$ 0.66\pm 0.04 $$ (Sign Correction); 0.34±0.04$$ 0.34\pm 0.04 $$ and 0.32±0.04$$ 0.32\pm 0.04 $$ (proposed techniques). The methods are found to be significantly different (p-value <0.05$$ <0.05 $$ ). Importantly, brain aneurysm data revealed that the Sign Correction method is not suitable, as it increases error when the flow is not unidirectional. All three methods improve the accuracy of in vivo data. CONCLUSION: The newly proposed methods outperform the Sign Correction method in improving dual-VENC PC-MRI images. Among them, the approach based on temporal differences has shown the highest accuracy.
- MeSH
- algoritmy * MeSH
- aorta * diagnostické zobrazování MeSH
- artefakty * MeSH
- fantomy radiodiagnostické MeSH
- interpretace obrazu počítačem metody MeSH
- intrakraniální aneurysma diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- počítačová simulace MeSH
- počítačové zpracování obrazu * metody MeSH
- poměr signál - šum * MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Fast Photochemical Oxidation of Proteins (FPOP) is a promising technique for studying protein structure and dynamics. The quality of insight provided by FPOP depends on the reliability of the determination of the modification site. This study investigates the performance of two search engines, Mascot and PEAKS, for the data processing of FPOP analyses. Comparison of Mascot and PEAKS of the hemoglobin--haptoglobin Bruker timsTOF data set (PXD021621) revealed greater consistency in the Mascot identification of modified peptides, with around 26% of the IDs being mutual for all three replicates, compared to approximately 22% for PEAKS. The intersection between Mascot and PEAKS results revealed a limited number (31%) of shared modified peptides. Principal Component Analysis (PCA) using the peptide-spectrum match (PSM) score, site probability, and peptide intensity was applied to evaluate the results, and the analyses revealed distinct clusters of modified peptides. Mascot showed the ability to assess confident site determination, even with lower PSM scores. However, high PSM scores from PEAKS did not guarantee a reliable determination of the modification site. Fragmentation coverage of the modification position played a crucial role in Mascot assignments, while the AScore localizations from PEAKS often become ambiguous because the software employs MS/MS merging.
In recent years, several international urological societies have published guidelines on the diagnosis, treatment, and follow-up of urethral strictures, but a guideline for the German-speaking region has not been available to date. This summary provides a detailed comparison of the guidelines of the European Association of Urology (EAU), American Urological Association (AUA) and the Société Internationale d'Urologie (SIU) with regard to the treatment of anterior urethral strictures, i.e. from the bulbar urethra to the meatus. In the following work, differences and specific recommendations in the guidelines are highlighted. In particular, the three guidelines largely agree with regard to diagnostic workup and follow-up. However, divergences exist in the management of anterior urethral strictures, particularly with regard to the use of endoscopic therapeutic approaches and the use of urethral stents. In addition, the EAU provides more comprehensive and detailed recommendations on urethroplasty techniques and specific patient follow-up. The EAU guidelines are the most current and were the first to include instructions for urethral strictures in women and individuals with gender incongruence after genital approximation surgery. Reconstructive urology is a rapidly evolving specialty and, thus, the clinical approach has been changing accordingly. Although guideline recommendations have become more inclusive and comprehensive, more high-quality data are needed to further improve the level of evidence.
- MeSH
- lidé MeSH
- správnost dat MeSH
- striktura uretry * diagnóza MeSH
- uretra chirurgie MeSH
- urologie * MeSH
- zákroky plastické chirurgie * MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- přehledy MeSH
- Geografické názvy
- Spojené státy americké MeSH
Endometrial biopsies are important in the diagnostic workup of women who present with abnormal uterine bleeding or hereditary risk of endometrial cancer. In general, approximately 10% of all endometrial biopsies demonstrate endometrial (pre)malignancy that requires specific treatment. As the diagnostic evaluation of mostly benign cases results in a substantial workload for pathologists, artificial intelligence (AI)-assisted preselection of biopsies could optimize the workflow. This study aimed to assess the feasibility of AI-assisted diagnosis for endometrial biopsies (endometrial Pipelle biopsy computer-aided diagnosis), trained on daily-practice whole-slide images instead of highly selected images. Endometrial biopsies were classified into 6 clinically relevant categories defined as follows: nonrepresentative, normal, nonneoplastic, hyperplasia without atypia, hyperplasia with atypia, and malignant. The agreement among 15 pathologists, within these classifications, was evaluated in 91 endometrial biopsies. Next, an algorithm (trained on a total of 2819 endometrial biopsies) rated the same 91 cases, and we compared its performance using the pathologist's classification as the reference standard. The interrater reliability among pathologists was moderate with a mean Cohen's kappa of 0.51, whereas for a binary classification into benign vs (pre)malignant, the agreement was substantial with a mean Cohen's kappa of 0.66. The AI algorithm performed slightly worse for the 6 categories with a moderate Cohen's kappa of 0.43 but was comparable for the binary classification with a substantial Cohen's kappa of 0.65. AI-assisted diagnosis of endometrial biopsies was demonstrated to be feasible in discriminating between benign and (pre)malignant endometrial tissues, even when trained on unselected cases. Endometrial premalignancies remain challenging for both pathologists and AI algorithms. Future steps to improve reliability of the diagnosis are needed to achieve a more refined AI-assisted diagnostic solution for endometrial biopsies that covers both premalignant and malignant diagnoses.
- MeSH
- biopsie MeSH
- hyperplazie MeSH
- lidé MeSH
- počítače * MeSH
- reprodukovatelnost výsledků MeSH
- studie proveditelnosti MeSH
- umělá inteligence * MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Ktrans$$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for Ktrans$$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize Ktrans$$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate Ktrans$$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for Ktrans$$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' Ktrans$$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIPIgold$$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIPIgold$$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in Ktrans$$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within Ktrans$$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.
- MeSH
- algoritmy MeSH
- kontrastní látky * MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- reprodukovatelnost výsledků MeSH
- software MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Microflow liquid chromatography interfaced with mass spectrometry (μLC-MS/MS) is increasingly applied for high-throughput profiling of biological samples and has been proven to have an acceptable trade-off between sensitivity and reproducibility. However, lipidomics applications are scarce. We optimized a μLC-MS/MS system utilizing a 1 mm inner diameter × 100 mm column coupled to a triple quadrupole mass spectrometer to establish a sensitive, high-throughput, and robust single-shot lipidomics workflow. Compared to conventional lipidomics methods, we achieve a ∼4-fold increase in response, facilitating quantification of 351 lipid species from a single iPSC-derived cerebral organoid during a 15 min LC-MS analysis. Consecutively, we injected 303 samples over ∼75 h to prove the robustness and reproducibility of the microflow separation. As a proof of concept, μLC-MS/MS analysis of Alzheimer's disease patient-derived iPSC cerebral organoid reveals differential lipid metabolism depending on APOE phenotype (E3/3 vs E4/4). Microflow separation proves to be an environmentally friendly and cost-effective method as it reduces the consumption of harmful solvents. Also, the data demonstrate robust, in-depth, high-throughput performance to enable routine clinical or biomedical applications.
- MeSH
- apolipoproteiny E MeSH
- chromatografie kapalinová metody MeSH
- fenotyp MeSH
- kapalinová chromatografie-hmotnostní spektrometrie * MeSH
- lidé MeSH
- lipidomika MeSH
- reprodukovatelnost výsledků MeSH
- tandemová hmotnostní spektrometrie * metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVE: Radiographic assessment of sacroiliac joints (SIJs) according to the modified New York (mNY) criteria is key in the classification of axial spondyloarthritis but has moderate interreader agreement. We aimed to investigate the improvements of the reliability in scoring SIJ radiographs after applying an online real-time iterative calibration (RETIC) module, in addition to a slideshow and video alone. METHODS: Nineteen readers, randomized to 2 groups (A or B), completed 3 calibration steps: (1) review of manuscripts, (2) review of slideshow and video with group A completing RETIC, and (3) re-review of slideshow and video with group B completing RETIC. The RETIC module gave instant feedback on readers' gradings and continued until predefined reliability ([Formula: see text]) targets for mNY positivity/negativity were met. Each step was followed by scoring different batches of 25 radiographs (exercises I to III). Agreement ([Formula: see text]) with an expert radiologist was assessed for mNY positivity/negativity and individual lesions. Improvements by training strategies were tested by linear mixed models. RESULTS: In exercises I, II, and III, mNY [Formula: see text] were 0.61, 0.76, and 0.84, respectively, in group A; and 0.70, 0.68, and 0.86, respectively, in group B (ie, increasing, mainly after RETIC completion). Improvements were observed for grading both mNY positivity/negativity and individual pathologies, both in experienced and, particularly, inexperienced readers. Completion of the RETIC module in addition to the slideshow and video caused a significant [Formula: see text] increase of 0.17 (95% CI 0.07-0.27; P = 0.002) for mNY-positive and mNY-negative grading, whereas completion of the slideshow and video alone did not ([Formula: see text] = 0.00, 95% CI -0.10 to 0.10; P = 0.99). CONCLUSION: Agreement on scoring radiographs according to the mNY criteria significantly improved when adding an online RETIC module, but not by slideshow and video alone.
- MeSH
- axiální spondyloartritida * diagnostické zobrazování MeSH
- lidé MeSH
- odchylka pozorovatele * MeSH
- rentgendiagnostika * metody MeSH
- reprodukovatelnost výsledků MeSH
- sakroiliakální kloub * diagnostické zobrazování MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
iv, 65 stran : ilustrace ; 30 cm
A doctoral dissertation that focuses on biostatistics and quantitative measurements in health care.
Coronavirus Anxiety Scale (CAS) is a widely used measure that captures somatic symptoms of coronavirus-related anxiety. In a large-scale collaboration spanning 60 countries (Ntotal = 21,513), we examined the CAS's measurement invariance and assessed the convergent validity of CAS scores in relation to the fear of COVID-19 (FCV-19S) and the satisfaction with life (SWLS-3) scales. We utilized both conventional exact invariance tests and alignment procedures, with results revealing that the single-factor model fit the data well in almost all countries. Partial scalar invariance was supported in a subset of 56 countries. To ensure the robustness of results, given the unbalanced samples, we employed resampling techniques both with and without replacement and found the results were more stable in larger samples. The alignment procedure demonstrated a high degree of measurement invariance with 9% of the parameters exhibiting noninvariance. We also conducted simulations of alignment using the parameters estimated in the current model. Findings demonstrated reliability of the means but indicated challenges in estimating the latent variances. Strong positive correlations between CAS and FCV-19S estimated with all three different approaches were found in most countries. Correlations of CAS and SWLS-3 were weak and negative but significantly differed from zero in several countries. Overall, the study provided support for the measurement invariance of the CAS and offered evidence of its convergent validity while also highlighting issues with variance estimation. (PsycInfo Database Record (c) 2024 APA, all rights reserved).
- MeSH
- COVID-19 * diagnóza MeSH
- lidé MeSH
- psychometrie metody MeSH
- reprodukovatelnost výsledků MeSH
- strach MeSH
- úzkost * diagnóza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH