Comparison of a new high-resolution monolithic column with core-shell and fully porous columns for the analysis of retinol and α-tocopherol in human serum and breast milk by ultra-high-performance liquid chromatography

B. Kučerová, L. Krčmová, D. Solichová, J. Plíšek, P. Solich,

. 2013 ; 36 (14) : 2223-2230.

Language English Country Germany

Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't

The reduction of analysis time, cost, and improvement of separation efficiency are the main requirements in the development of high-throughput assay methods in bioanalysis. It can be achieved either by ultra-high-performance liquid chromatography (UHPLC) using stationary phases with small particles (<2 μm) at high back pressures or by using opposite direction--monolithic stationary phases with low back pressures. The application of new types of monolithic stationary phases for UHPLC is a novel idea combining these two different paths. The aim of this work was to test the recently introduced second-generation of monolithic column Chromolith® HighResolution for UHPLC analysis of liposoluble vitamins in comparison with core-shell and fully porous sub-2 μm columns with different particle sizes, column lengths, and shapes. The separation efficiency, peak shape, resolution, time of analysis, consumption of mobile phase, and lifetime of columns were calculated and compared. The main purpose of the study was to find a new, not only economical option of separation of liposoluble vitamins for routine practice.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14051079
003      
CZ-PrNML
005      
20170411121151.0
007      
ta
008      
140401s2013 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/jssc.201300242 $2 doi
035    __
$a (PubMed)23677738
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Červinková, Barbora $7 xx0209609
245    10
$a Comparison of a new high-resolution monolithic column with core-shell and fully porous columns for the analysis of retinol and α-tocopherol in human serum and breast milk by ultra-high-performance liquid chromatography / $c B. Kučerová, L. Krčmová, D. Solichová, J. Plíšek, P. Solich,
520    9_
$a The reduction of analysis time, cost, and improvement of separation efficiency are the main requirements in the development of high-throughput assay methods in bioanalysis. It can be achieved either by ultra-high-performance liquid chromatography (UHPLC) using stationary phases with small particles (<2 μm) at high back pressures or by using opposite direction--monolithic stationary phases with low back pressures. The application of new types of monolithic stationary phases for UHPLC is a novel idea combining these two different paths. The aim of this work was to test the recently introduced second-generation of monolithic column Chromolith® HighResolution for UHPLC analysis of liposoluble vitamins in comparison with core-shell and fully porous sub-2 μm columns with different particle sizes, column lengths, and shapes. The separation efficiency, peak shape, resolution, time of analysis, consumption of mobile phase, and lifetime of columns were calculated and compared. The main purpose of the study was to find a new, not only economical option of separation of liposoluble vitamins for routine practice.
650    _2
$a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $7 D002851
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mateřské mléko $x chemie $7 D008895
650    _2
$a velikost částic $7 D010316
650    _2
$a poréznost $7 D016062
650    _2
$a syntetické pryskyřice $x chemie $7 D012117
650    _2
$a vitamin A $x analýza $x krev $7 D014801
650    _2
$a alfa-tokoferol $x analýza $x krev $7 D024502
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Krčmová Kujovská, Lenka, $u - $d 1981- $7 xx0209338
700    1_
$a Solichová, Dagmar $u -
700    1_
$a Plíšek, Jiří $u -
700    1_
$a Solich, Petr $u -
773    0_
$w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 36, č. 14 (2013), s. 2223-2230
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23677738 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140401 $b ABA008
991    __
$a 20170411121450 $b ABA008
999    __
$a ok $b bmc $g 1018215 $s 849659
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 36 $c 14 $d 2223-2230 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
LZP    __
$a Pubmed-20140401

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...