HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development

L. Havlíková, H. Vlčková, P. Solich, L. Nováková,

. 2013 ; 5 (19) : 2345-57.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14063938

BACKGROUND: Matrix effects are considered to be a main obstacle of quantitative bioanalytical LC-MS/MS methods. Therefore it is often required to minimize them in order to increase method reliability. HILIC has been referenced as one of possible approaches. However, there is a lack of experimental evidence in scientific literature so far. METHODOLOGY: Matrix effects were evaluated using spiked serum samples after SPE and protein precipitation prior to UHPLC-ESI-MS/MS. Chromatography was performed in both HILIC and reversed-phase mode. The influence of the matrix effects on the signal response was assessed using a set of 34 compounds of pharmaceutical interest and post-extraction addition approach. RESULTS: The advantages and drawbacks of the HILIC and reversed-phase chromatographic modes were compared and discussed in detail. CONCLUSION: HILIC demonstrated the potential to reduce the occurrence of matrix effects when a more thorough sample pretreatment procedure such as SPE was applied.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14063938
003      
CZ-PrNML
005      
20140904113444.0
007      
ta
008      
140704s2013 enk f 000 0|eng||
009      
AR
024    7_
$a 10.4155/bio.13.217 $2 doi
035    __
$a (PubMed)24066620
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Havlíková, Lucie $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovského 1203, Hradec Králové 500 05, Czech Republic.
245    10
$a HILIC UHPLC-MS/MS for fast and sensitive bioanalysis: accounting for matrix effects in method development / $c L. Havlíková, H. Vlčková, P. Solich, L. Nováková,
520    9_
$a BACKGROUND: Matrix effects are considered to be a main obstacle of quantitative bioanalytical LC-MS/MS methods. Therefore it is often required to minimize them in order to increase method reliability. HILIC has been referenced as one of possible approaches. However, there is a lack of experimental evidence in scientific literature so far. METHODOLOGY: Matrix effects were evaluated using spiked serum samples after SPE and protein precipitation prior to UHPLC-ESI-MS/MS. Chromatography was performed in both HILIC and reversed-phase mode. The influence of the matrix effects on the signal response was assessed using a set of 34 compounds of pharmaceutical interest and post-extraction addition approach. RESULTS: The advantages and drawbacks of the HILIC and reversed-phase chromatographic modes were compared and discussed in detail. CONCLUSION: HILIC demonstrated the potential to reduce the occurrence of matrix effects when a more thorough sample pretreatment procedure such as SPE was applied.
650    _2
$a krevní proteiny $x chemie $7 D001798
650    12
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    12
$a chromatografie s reverzní fází $7 D056148
650    _2
$a hydrofobní a hydrofilní interakce $7 D057927
650    _2
$a léčivé přípravky $x krev $7 D004364
650    _2
$a extrakce na pevné fázi $7 D052616
650    _2
$a rozpouštědla $x chemie $7 D012997
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
650    12
$a tandemová hmotnostní spektrometrie $7 D053719
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Vlčková, Hana
700    1_
$a Solich, Petr
700    1_
$a Nováková, Lucie
773    0_
$w MED00184533 $t Bioanalysis $x 1757-6199 $g Roč. 5, č. 19 (2013), s. 2345-57
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24066620 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20140704 $b ABA008
991    __
$a 20140904113838 $b ABA008
999    __
$a ok $b bmc $g 1031422 $s 862670
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 5 $c 19 $d 2345-57 $i 1757-6199 $m Bioanalysis $n Bioanal. $x MED00184533
LZP    __
$a Pubmed-20140704

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...