Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes
E. T. Detorakis, E. E. Drakonaki, H. Ginis, N. Karyotakis, I. G. Pallikaris
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
Digitální knihovna NLK
Plný text - Článek
Číslo
Ročník
Zdroj
Zdroj
NLK
Directory of Open Access Journals
od 1997
Free Medical Journals
od 1997
Open Access Digital Library
od 1997-01-01
Medline Complete (EBSCOhost)
od 2012-06-01
ROAD: Directory of Open Access Scholarly Resources
od 1997
- MeSH
- atropin farmakologie MeSH
- corpus ciliare účinky léků patofyziologie ultrasonografie MeSH
- elastografie * MeSH
- králíci MeSH
- miotika farmakologie MeSH
- mydriatika farmakologie MeSH
- oční čočka účinky léků patofyziologie ultrasonografie MeSH
- pilokarpin farmakologie MeSH
- pružnost účinky léků fyziologie MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. METHODS: Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. RESULTS: Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. CONCLUSIONS: Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.
Department of Medical Imaging University Hospital of Heraklion Greece
Institute of Vision and Optics University of Crete
University Hospital of Heraklion Greece Department of Ophthalmology
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14071295
- 003
- CZ-PrNML
- 005
- 20141006111004.0
- 007
- ta
- 008
- 140916s2014 xr a f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14712/18059694.2014.2 $2 doi
- 035 __
- $a (PubMed)25006657
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Detorakis, Efstathios T. $u Institute of Vision & Optics, University of Crete
- 245 10
- $a Evaluation of iridociliary and lenticular elasticity using shear-wave elastography in rabbit eyes / $c E. T. Detorakis, E. E. Drakonaki, H. Ginis, N. Karyotakis, I. G. Pallikaris
- 520 9_
- $a INTRODUCTION: A previous study has employed shear-wave ultrasound elastographic imaging to assess corneal rigidity in an ex-vivo porcine eye model. This study employs the same modality in vivo in a rabbit eye model in order to assess lens, ciliary body and total ocular rigidity changes following the instillation of atropine and pilocarpine. METHODS: Ten non-pigmented female rabbits were examined. Measurements of the lens, ciliary body and total ocular rigidity as well as lens thickness and anterior chamber depth were taken with the Aixplorer system (SuperSonic Imagine, Aix-en-Provence, France) with the SuperLinear™ SL 15-4 transducer in both eyes at baseline as well as after pilocarpine and atropine instillation. The IOP was also measured with the TonoPen tonometer. RESULTS: Changes in rigidity in the examined areas following atropine instillation were statistically not significant. Ciliary body rigidity was significantly increased whereas lens and total ocular rigidity were significantly reduced following pilocarpine instillation. The decrease in lens rigidity following pilocarpine was significantly associated with the respective increase in ciliary body rigidity. CONCLUSIONS: Shear-wave ultrasound elastography can detect in vivo rigidity changes in the anterior segment of the rabbit eye model and may potentially be applied in human eyes, providing useful clinical information on conditions in which rigidity changes play an important role, such as glaucoma, pseudoexfoliation syndrome or presbyopia.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a atropin $x farmakologie $7 D001285
- 650 _2
- $a corpus ciliare $x účinky léků $x patofyziologie $x ultrasonografie $7 D002924
- 650 _2
- $a pružnost $x účinky léků $x fyziologie $7 D004548
- 650 12
- $a elastografie $7 D054459
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a oční čočka $x účinky léků $x patofyziologie $x ultrasonografie $7 D007908
- 650 _2
- $a miotika $x farmakologie $7 D008916
- 650 _2
- $a mydriatika $x farmakologie $7 D009184
- 650 _2
- $a pilokarpin $x farmakologie $7 D010862
- 650 _2
- $a králíci $7 D011817
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Drakonaki, Eleni E. $u Department of Medical Imaging, University Hospital of Heraklion, Greece
- 700 1_
- $a Ginis, Harilaos $u Institute of Vision & Optics, University of Crete
- 700 1_
- $a Karyotakis, Nikolaos $u Institute of Vision & Optics, University of Crete
- 700 1_
- $a Pallikaris, Ioannis G. $u University Hospital of Heraklion, Greece, Department of Ophthalmology; Institute of Vision & Optics, University of Crete
- 773 0_
- $w MED00010947 $t Acta medica (Hradec Králové) / Universitas Carolina, Facultas Medica Hradec Králové $x 1211-4286 $g Roč. 57, č. 1 (2014), s. 9-14
- 856 41
- $u https://actamedica.lfhk.cuni.cz/media/pdf/am_2014057010009.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 3077 $c 1072 $y 4 $z 0
- 990 __
- $a 20140916 $b ABA008
- 991 __
- $a 20141006111337 $b ABA008
- 999 __
- $a ok $b bmc $g 1041881 $s 870164
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 57 $c 1 $d 9-14 $i 1211-4286 $m Acta Medica $n Acta Med. (Hradec Král.) $x MED00010947
- LZP __
- $b NLK118 $a Pubmed-20140916