Resistance of the isolative protective garment designated for specialists´ protection against selected chlorinated hydrocarbons

Pavel Otrisal, Stanislav Florus

. 2014 ; 83 (1) : 11-17.

Jazyk angličtina Země Česko

Typ dokumentu práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc14071325

Chlorinated hydrocarbons are very often used and are relatively dangerous substances from healthy risk point of view. While manipulating with them, mainly in large volumes, individual protective equipment (IPE) must be used in a protection position. Users are supposed to know the construction material breakthrough time especially in case of long-term usage of personal IPE and in the situation when contamination of them is real. Studying connections between a chemical compound structure and the structure of IPE characterised by barrier materials enables us to understand present body protective devices protection quality and gives us an option to choose barrier materials with targeted properties. In this article there are results of breakthrough time of isolating protection folio with a butyl rubber barrier layer in relation to chlorinated ethanes. This material is used for protection of specialists of both Fire Rescue Brigades and the Czech Armed Forces Chemical Corps. The PIEZOTEST device has been used for detection of permeated chemicals. The Quartz Crystal Microbalance (QCM) sensor is a part of PIEZOTEST device.

Citace poskytuje Crossref.org

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc14071325
003      
CZ-PrNML
005      
20150121113519.0
007      
ta
008      
140916s2014 xr da f 000 0eng||
009      
AR
024    7_
$a 10.31482/mmsl.2014.003 $2 doi
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Otřísal, Pavel, $d 1972- $7 mzk2007408423 $u NBC Defence Institute of the University of Defence, Sídliště Víta Nejedlého, 682 01 Vyškov, Czech Republic
245    10
$a Resistance of the isolative protective garment designated for specialists´ protection against selected chlorinated hydrocarbons / $c Pavel Otrisal, Stanislav Florus
504    __
$a Literatura
520    9_
$a Chlorinated hydrocarbons are very often used and are relatively dangerous substances from healthy risk point of view. While manipulating with them, mainly in large volumes, individual protective equipment (IPE) must be used in a protection position. Users are supposed to know the construction material breakthrough time especially in case of long-term usage of personal IPE and in the situation when contamination of them is real. Studying connections between a chemical compound structure and the structure of IPE characterised by barrier materials enables us to understand present body protective devices protection quality and gives us an option to choose barrier materials with targeted properties. In this article there are results of breakthrough time of isolating protection folio with a butyl rubber barrier layer in relation to chlorinated ethanes. This material is used for protection of specialists of both Fire Rescue Brigades and the Czech Armed Forces Chemical Corps. The PIEZOTEST device has been used for detection of permeated chemicals. The Quartz Crystal Microbalance (QCM) sensor is a part of PIEZOTEST device.
650    _2
$a testování materiálů $x metody $x statistika a číselné údaje $7 D008422
650    12
$a ochranné oděvy $7 D011481
650    _2
$a mikrorovnovážné techniky křemenného krystalu $x statistika a číselné údaje $7 D058525
650    _2
$a nebezpečné látky $x chemie $7 D015386
650    12
$a permeabilita $7 D010539
650    12
$a chlorované uhlovodíky $x chemie $7 D006843
650    _2
$a ethylendichloridy $x chemie $7 D005025
650    _2
$a trichlorethany $x chemie $7 D014240
650    _2
$a ethan $x analogy a deriváty $x chemie $7 D004980
650    _2
$a elastomery $x chemie $7 D020724
650    _2
$a rozpustnost $7 D012995
650    _2
$a časové faktory $7 D013997
653    00
$a lag-time
653    00
$a butyl rubber
653    00
$a steady state permeation rate
653    00
$a breakthrough time
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Florus, Stanislav, $d 1963- $7 mzk2007363541 $u NBC Defence Institute of the University of Defence, Sídliště Víta Nejedlého, 682 01 Vyškov, Czech Republic
773    0_
$t Vojenské zdravotnické listy $x 0372-7025 $g Roč. 83, č. 1 (2014), s. 11-17 $w MED00011116
856    41
$u http://www.mmsl.cz/archive $y domovská stránka časopisu - plný text volně přístupný
910    __
$a ABA008 $b A 3 $c 1073 $y 4 $z 0
990    __
$a 20140916085423 $b ABA008
991    __
$a 20150121113708 $b ABA008
999    __
$a ok $b bmc $g 1039158 $s 870195
BAS    __
$a 3
BMC    __
$a 2014 $b 83 $c 1 $d 11-17 $i 0372-7025 $m Vojenské zdravotnické listy $n Vojen. zdr. listy $x MED00011116
LZP    __
$c NLK188 $d 20141201 $a NLK 2014-48/vt

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...