-
Something wrong with this record ?
Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial
G. Hindricks, M. Taborsky, M. Glikson, U. Heinrich, B. Schumacher, A. Katz, J. Brachmann, T. Lewalter, A. Goette, M. Block, J. Kautzner, S. Sack, D. Husser, C. Piorkowski, P. Søgaard, . ,
Language English Country England, Great Britain
Document type Journal Article, Multicenter Study, Randomized Controlled Trial, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 1992-01-04 to 3 months ago
Nursing & Allied Health Database (ProQuest)
from 1992-01-04 to 3 months ago
Health & Medicine (ProQuest)
from 1992-01-04 to 3 months ago
Family Health Database (ProQuest)
from 1992-01-04 to 3 months ago
Psychology Database (ProQuest)
from 1992-01-04 to 3 months ago
Health Management Database (ProQuest)
from 1992-01-04 to 3 months ago
Public Health Database (ProQuest)
from 1992-01-04 to 3 months ago
- MeSH
- Monitoring, Ambulatory instrumentation MeSH
- Defibrillators, Implantable * MeSH
- Humans MeSH
- Aged MeSH
- Heart Failure physiopathology therapy MeSH
- Telemedicine methods MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Multicenter Study MeSH
- Research Support, Non-U.S. Gov't MeSH
- Randomized Controlled Trial MeSH
- Geographicals
- Australia MeSH
- Europe MeSH
- Israel MeSH
BACKGROUND: An increasing number of patients with heart failure receive implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation defibrillators (CRT-Ds) with telemonitoring function. Early detection of worsening heart failure, or upstream factors predisposing to worsening heart failure, by implant-based telemonitoring might enable pre-emptive intervention and improve outcomes, but the evidence is weak. We investigated this possibility in IN-TIME, a clinical trial. METHODS: We did this randomised, controlled trial at 36 tertiary clinical centres and hospitals in Australia, Europe, and Israel. We enrolled patients with chronic heart failure, NYHA class II-III symptoms, ejection fraction of no more than 35%, optimal drug treatment, no permanent atrial fibrillation, and a recent dual-chamber ICD or CRT-D implantation. After a 1 month run-in phase, patients were randomly assigned (1:1) to either automatic, daily, implant-based, multiparameter telemonitoring in addition to standard care or standard care without telemonitoring. Investigators were not masked to treatment allocation. Patients were masked to allocation unless they were contacted because of telemonitoring findings. Follow-up was 1 year. The primary outcome measure was a composite clinical score combining all-cause death, overnight hospital admission for heart failure, change in NYHA class, and change in patient global self-assessment, for the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT00538356. FINDINGS: We enrolled 716 patients, of whom 664 were randomly assigned (333 to telemonitoring, 331 to control). Mean age was 65·5 years and mean ejection fraction was 26%. 285 (43%) of patients had NYHA functional class II and 378 (57%) had NYHA class III. Most patients received CRT-Ds (390; 58·7%). At 1 year, 63 (18·9%) of 333 patients in the telemonitoring group versus 90 (27·2%) of 331 in the control group (p=0·013) had worsened composite score (odds ratio 0·63, 95% CI 0·43-0·90). Ten versus 27 patients died during follow-up. INTERPRETATION: Automatic, daily, implant-based, multiparameter telemonitoring can significantly improve clinical outcomes for patients with heart failure. Such telemonitoring is feasible and should be used in clinical practice. FUNDING: Biotronik SE & Co. KG.
Barzilai Medical Center Ashkelon Israel
Chaim Sheba Medical Center Tel Hashomer Israel
Heart Centre and Clinical Institute Aalborg University Hospital Aalborg Denmark
Herz und Gefäßklinikum GmbH Bad Neustadt Bad Neustadt Germany
Herzzentrum Leipzig Leipzig Germany
Institute for Clinical and Experimental Medicine Prague Czech Republic
Isar Herzzentrum Munich Germany
Klinik Augustinum Munich Germany
Klinikum Coburg GmbH Coburg Germany
Klinikum Schwabing Munich Germany
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14074114
- 003
- CZ-PrNML
- 005
- 20141009093744.0
- 007
- ta
- 008
- 141006s2014 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/S0140-6736(14)61176-4 $2 doi
- 035 __
- $a (PubMed)25131977
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Hindricks, Gerhard $u Herzzentrum Leipzig, Leipzig, Germany. Electronic address: gerhard.hindricks@medizin.uni-leipzig.de.
- 245 10
- $a Implant-based multiparameter telemonitoring of patients with heart failure (IN-TIME): a randomised controlled trial / $c G. Hindricks, M. Taborsky, M. Glikson, U. Heinrich, B. Schumacher, A. Katz, J. Brachmann, T. Lewalter, A. Goette, M. Block, J. Kautzner, S. Sack, D. Husser, C. Piorkowski, P. Søgaard, . ,
- 520 9_
- $a BACKGROUND: An increasing number of patients with heart failure receive implantable cardioverter-defibrillators (ICDs) or cardiac resynchronisation defibrillators (CRT-Ds) with telemonitoring function. Early detection of worsening heart failure, or upstream factors predisposing to worsening heart failure, by implant-based telemonitoring might enable pre-emptive intervention and improve outcomes, but the evidence is weak. We investigated this possibility in IN-TIME, a clinical trial. METHODS: We did this randomised, controlled trial at 36 tertiary clinical centres and hospitals in Australia, Europe, and Israel. We enrolled patients with chronic heart failure, NYHA class II-III symptoms, ejection fraction of no more than 35%, optimal drug treatment, no permanent atrial fibrillation, and a recent dual-chamber ICD or CRT-D implantation. After a 1 month run-in phase, patients were randomly assigned (1:1) to either automatic, daily, implant-based, multiparameter telemonitoring in addition to standard care or standard care without telemonitoring. Investigators were not masked to treatment allocation. Patients were masked to allocation unless they were contacted because of telemonitoring findings. Follow-up was 1 year. The primary outcome measure was a composite clinical score combining all-cause death, overnight hospital admission for heart failure, change in NYHA class, and change in patient global self-assessment, for the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT00538356. FINDINGS: We enrolled 716 patients, of whom 664 were randomly assigned (333 to telemonitoring, 331 to control). Mean age was 65·5 years and mean ejection fraction was 26%. 285 (43%) of patients had NYHA functional class II and 378 (57%) had NYHA class III. Most patients received CRT-Ds (390; 58·7%). At 1 year, 63 (18·9%) of 333 patients in the telemonitoring group versus 90 (27·2%) of 331 in the control group (p=0·013) had worsened composite score (odds ratio 0·63, 95% CI 0·43-0·90). Ten versus 27 patients died during follow-up. INTERPRETATION: Automatic, daily, implant-based, multiparameter telemonitoring can significantly improve clinical outcomes for patients with heart failure. Such telemonitoring is feasible and should be used in clinical practice. FUNDING: Biotronik SE & Co. KG.
- 650 _2
- $a senioři $7 D000368
- 650 12
- $a defibrilátory implantabilní $7 D017147
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a srdeční selhání $x patofyziologie $x terapie $7 D006333
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a ambulantní monitorování $x přístrojové vybavení $7 D018670
- 650 _2
- $a telemedicína $x metody $7 D017216
- 650 _2
- $a výsledek terapie $7 D016896
- 651 _2
- $a Austrálie $7 D001315
- 651 _2
- $a Evropa $7 D005060
- 651 _2
- $a Izrael $7 D007557
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a multicentrická studie $7 D016448
- 655 _2
- $a randomizované kontrolované studie $7 D016449
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Taborsky, Milos $u Department of Internal Medicine I-Cardiology, Faculty of Medicine and Dentistry, Olomouc, Czech Republic.
- 700 1_
- $a Glikson, Michael $u Chaim Sheba Medical Center, Tel-Hashomer, Israel.
- 700 1_
- $a Heinrich, Ullus $u Praxis Dr Heinrich, Nordhausen, Germany.
- 700 1_
- $a Schumacher, Burghard $u Herz-und Gefäßklinikum GmbH Bad Neustadt, Bad Neustadt, Germany.
- 700 1_
- $a Katz, Amos $u Barzilai Medical Center, Ashkelon, Israel.
- 700 1_
- $a Brachmann, Johannes $u Klinikum Coburg GmbH, Coburg, Germany.
- 700 1_
- $a Lewalter, Thorsten $u Isar Herzzentrum, Munich, Germany.
- 700 1_
- $a Goette, Andreas $u St Vincenz Krankenhaus GmbH, Paderborn, Germany.
- 700 1_
- $a Block, Michael $u Klinik Augustinum, Munich, Germany.
- 700 1_
- $a Kautzner, Josef $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic.
- 700 1_
- $a Sack, Stefan $u Klinikum Schwabing, Munich, Germany.
- 700 1_
- $a Husser, Daniela $u Herzzentrum Leipzig, Leipzig, Germany.
- 700 1_
- $a Piorkowski, Christopher $u Herzzentrum Leipzig, Leipzig, Germany.
- 700 1_
- $a Søgaard, Peter $u Heart Centre and Clinical Institute, Aalborg University Hospital, Aalborg, Denmark.
- 700 1_
- $a ,
- 773 0_
- $w MED00010161 $t Lancet $x 1474-547X $g Roč. 384, č. 9943 (2014), s. 583-90
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25131977 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20141006 $b ABA008
- 991 __
- $a 20141009094133 $b ABA008
- 999 __
- $a ok $b bmc $g 1041997 $s 873026
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 384 $c 9943 $d 583-90 $i 1474-547X $m Lancet $n Lancet $x MED00010161
- LZP __
- $a Pubmed-20141006