             Something wrong with this record ?
 
Movement of the patient and the cone beam computed tomography scanner: objectives and possible solutions
T. Hanzelka, J. Dusek, F. Ocasek, J. Kucera, J. Sedy, J. Benes, G. Pavlikova, R. Foltan,
Language English Country United States
Document type Journal Article, Randomized Controlled Trial, Research Support, Non-U.S. Gov't
- MeSH
 - Artifacts MeSH
 - Video Recording MeSH
 - Restraint, Physical methods MeSH
 - Noise MeSH
 - Humans MeSH
 - Cone-Beam Computed Tomography * MeSH
 - Movement * MeSH
 - Prospective Studies MeSH
 - Vibration MeSH
 - Vision, Ocular MeSH
 - Check Tag
 - Humans MeSH
 - Publication type
 - Journal Article MeSH
 - Research Support, Non-U.S. Gov't MeSH
 - Randomized Controlled Trial MeSH
 
OBJECTIVE: This study aimed (1) to determine whether scanner arm rotation causes significant movement of the head restraint and (2) to measure patient movement and its variation during the scan. STUDY DESIGN: The iCAT scanner and a high-speed camera were used. The 40 patients were divided into 2 groups: the open-eyed group and the blindfolded group. RESULTS: The mean level of head restraint movement was 0.130 mm, with a significantly higher level at the beginning, probably owing to the accelerating arm. Mean movement of patients was 1.135 mm and 1.119 mm in the open-eyed and blindfolded groups, respectively. Patient movement was also significantly higher at the beginning of the scan, when noise and vibrations are likely to surprise the patient. CONCLUSIONS: Patient instruction and a dry-run scan should be done by clinicians. Manufacturers should consider separating the seat and head restraint from the rest of the scanner to avoid vibration transfer.
References provided by Crossref.org
- 000
 - 00000naa a2200000 a 4500
 
- 001
 - bmc14074514
 
- 003
 - CZ-PrNML
 
- 005
 - 20141010102936.0
 
- 007
 - ta
 
- 008
 - 141006s2013 xxu f 000 0|eng||
 
- 009
 - AR
 
- 024 7_
 - $a 10.1016/j.oooo.2013.08.010 $2 doi
 
- 035 __
 - $a (PubMed)24237728
 
- 040 __
 - $a ABA008 $b cze $d ABA008 $e AACR2
 
- 041 0_
 - $a eng
 
- 044 __
 - $a xxu
 
- 100 1_
 - $a Hanzelka, Tomas $u Institute of Clinical and Experimental Stomatology, First Faculty of Medicine, Charles University and General University Hospital, Prague, Czech Republic. Electronic address: thanzelka@gmail.com.
 
- 245 10
 - $a Movement of the patient and the cone beam computed tomography scanner: objectives and possible solutions / $c T. Hanzelka, J. Dusek, F. Ocasek, J. Kucera, J. Sedy, J. Benes, G. Pavlikova, R. Foltan,
 
- 520 9_
 - $a OBJECTIVE: This study aimed (1) to determine whether scanner arm rotation causes significant movement of the head restraint and (2) to measure patient movement and its variation during the scan. STUDY DESIGN: The iCAT scanner and a high-speed camera were used. The 40 patients were divided into 2 groups: the open-eyed group and the blindfolded group. RESULTS: The mean level of head restraint movement was 0.130 mm, with a significantly higher level at the beginning, probably owing to the accelerating arm. Mean movement of patients was 1.135 mm and 1.119 mm in the open-eyed and blindfolded groups, respectively. Patient movement was also significantly higher at the beginning of the scan, when noise and vibrations are likely to surprise the patient. CONCLUSIONS: Patient instruction and a dry-run scan should be done by clinicians. Manufacturers should consider separating the seat and head restraint from the rest of the scanner to avoid vibration transfer.
 
- 650 _2
 - $a artefakty $7 D016477
 
- 650 12
 - $a počítačová tomografie s kuželovým svazkem $7 D054893
 
- 650 _2
 - $a lidé $7 D006801
 
- 650 12
 - $a pohyb $7 D009068
 
- 650 _2
 - $a hluk $7 D009622
 
- 650 _2
 - $a prospektivní studie $7 D011446
 
- 650 _2
 - $a fyzické omezení $x metody $7 D012149
 
- 650 _2
 - $a vibrace $7 D014732
 
- 650 _2
 - $a audiovizuální záznam $7 D014741
 
- 650 _2
 - $a zrak $7 D014785
 
- 655 _2
 - $a časopisecké články $7 D016428
 
- 655 _2
 - $a randomizované kontrolované studie $7 D016449
 
- 655 _2
 - $a práce podpořená grantem $7 D013485
 
- 700 1_
 - $a Dusek, Jaroslav
 
- 700 1_
 - $a Ocasek, Filip
 
- 700 1_
 - $a Kucera, Josef
 
- 700 1_
 - $a Sedy, Jiri
 
- 700 1_
 - $a Benes, Jiri
 
- 700 1_
 - $a Pavlikova, Gabriela
 
- 700 1_
 - $a Foltan, Rene
 
- 773 0_
 - $w MED00181743 $t Oral surgery, oral medicine, oral pathology and oral radiology $x 2212-4411 $g Roč. 116, č. 6 (2013), s. 769-73
 
- 856 41
 - $u https://pubmed.ncbi.nlm.nih.gov/24237728 $y Pubmed
 
- 910 __
 - $a ABA008 $b sig $c sign $y a $z 0
 
- 990 __
 - $a 20141006 $b ABA008
 
- 991 __
 - $a 20141010103326 $b ABA008
 
- 999 __
 - $a ok $b bmc $g 1042397 $s 873426
 
- BAS __
 - $a 3
 
- BAS __
 - $a PreBMC
 
- BMC __
 - $a 2013 $b 116 $c 6 $d 769-73 $i 2212-4411 $m Oral surgery, oral medicine, oral pathology and oral radiology $n Oral Surg Oral Med Oral Pathol Oral Radiol $x MED00181743
 
- LZP __
 - $a Pubmed-20141006