INTRODUCTION AND HYPOTHESIS: The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. METHODS: This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30° flexion and 30° abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as the primary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. RESULTS: In the group of formalin-embalmed bodies the mean distance from the anchoring device to the obturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases out of 10 the anchor was in the complex of the obturator membrane and obturator muscles. CONCLUSION: The distance from the anchor to the obturator nerve was more than 2 cm in all cases. Correct placement in the obturator membrane was achieved in 65.6 % of cases. In 87.5 % of cases the anchor was placed within the complex of obturator membrane and obturator muscles.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc14074724
003      
CZ-PrNML
005      
20181012080253.0
007      
ta
008      
141006s2013 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00192-013-2139-2 $2 doi
035    __
$a (PubMed)23749242
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Hubka, Petr $u Department of Gynecology and Obstetrics, Charles University in Prague, First Faculty of Medicine and General Teaching Hospital, Apolinarska 18, Prague 2, 12000, Czech Republic. $7 xx0128583
245    10
$a Fixation of the Ajust minisling based upon cadaveric study / $c P. Hubka, O. Nanka, A. Martan, K. Svabik, R. El-Haddad, J. Masata,
520    9_
$a INTRODUCTION AND HYPOTHESIS: The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. METHODS: This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30° flexion and 30° abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as the primary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. RESULTS: In the group of formalin-embalmed bodies the mean distance from the anchoring device to the obturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases out of 10 the anchor was in the complex of the obturator membrane and obturator muscles. CONCLUSION: The distance from the anchor to the obturator nerve was more than 2 cm in all cases. Correct placement in the obturator membrane was achieved in 65.6 % of cases. In 87.5 % of cases the anchor was placed within the complex of obturator membrane and obturator muscles.
650    _2
$a mrtvola $7 D002102
650    _2
$a kryoprezervace $7 D015925
650    _2
$a disekce $7 D004210
650    _2
$a balzamování $7 D004615
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a nervus obturatorius $x anatomie a histologie $7 D009776
650    _2
$a polohování pacienta $7 D056888
650    _2
$a pánev $x anatomie a histologie $7 D010388
650    _2
$a implantace protézy $x metody $7 D019919
650    12
$a retence protézy $7 D060489
650    12
$a suburetrální pásky $7 D053825
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Naňka, Ondřej, $d 1972- $7 mzk2006348905
700    1_
$a Martan, Alois, $d 1952- $7 nlk20010103172
700    1_
$a Švabík, Kamil $7 xx0061005
700    1_
$a El-Haddad, Rachid $7 xx0093282
700    1_
$a Mašata, Jaromír, $d 1969- $7 mzk2004250988
773    0_
$w MED00002395 $t International urogynecology journal $x 1433-3023 $g Roč. 24, č. 12 (2013), s. 2119-2123
856    41
$u https://pubmed.ncbi.nlm.nih.gov/23749242 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20141006 $b ABA008
991    __
$a 20181012080744 $b ABA008
999    __
$a ok $b bmc $g 1042607 $s 873636
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2013 $b 24 $c 12 $d 2119-2123 $i 1433-3023 $m International urogynecology journal $n Int. urogynecol. j. (Print) $x MED00002395
GRA    __
$a NT14162 $p MZ0
LZP    __
$a Pubmed-20141006

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...