Je něco špatně v tomto záznamu ?
Fixation of the Ajust minisling based upon cadaveric study
P. Hubka, O. Nanka, A. Martan, K. Svabik, R. El-Haddad, J. Masata,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NT14162
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
ProQuest Central
od 1997-01-01 do 2017-12-31
Medline Complete (EBSCOhost)
od 2010-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 1997-01-01 do 2017-12-31
- MeSH
- balzamování MeSH
- disekce MeSH
- implantace protézy metody MeSH
- kryoprezervace MeSH
- lidé MeSH
- mrtvola MeSH
- nervus obturatorius anatomie a histologie MeSH
- pánev anatomie a histologie MeSH
- polohování pacienta MeSH
- retence protézy * MeSH
- suburetrální pásky * MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
INTRODUCTION AND HYPOTHESIS: The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. METHODS: This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30° flexion and 30° abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as the primary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. RESULTS: In the group of formalin-embalmed bodies the mean distance from the anchoring device to the obturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases out of 10 the anchor was in the complex of the obturator membrane and obturator muscles. CONCLUSION: The distance from the anchor to the obturator nerve was more than 2 cm in all cases. Correct placement in the obturator membrane was achieved in 65.6 % of cases. In 87.5 % of cases the anchor was placed within the complex of obturator membrane and obturator muscles.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc14074724
- 003
- CZ-PrNML
- 005
- 20181012080253.0
- 007
- ta
- 008
- 141006s2013 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00192-013-2139-2 $2 doi
- 035 __
- $a (PubMed)23749242
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Hubka, Petr $u Department of Gynecology and Obstetrics, Charles University in Prague, First Faculty of Medicine and General Teaching Hospital, Apolinarska 18, Prague 2, 12000, Czech Republic. $7 xx0128583
- 245 10
- $a Fixation of the Ajust minisling based upon cadaveric study / $c P. Hubka, O. Nanka, A. Martan, K. Svabik, R. El-Haddad, J. Masata,
- 520 9_
- $a INTRODUCTION AND HYPOTHESIS: The objective was to describe the fixation site of the anchor of the Ajust mid-urethral minisling. METHODS: This cadaveric study was based on a group of 11 formalin-embalmed bodies with legs positioned in 30° flexion and 30° abduction, and a group of five fresh-frozen bodies with legs positioned as normal during the procedure. The groups were later compared. The fixation site was dissected and described. The distance to the obturator bundle was considered as the primary safety parameter. To compare the groups of fresh-frozen bodies and formalin-embalmed bodies, the Student's t test and Mann-Whitney test were used. RESULTS: In the group of formalin-embalmed bodies the mean distance from the anchoring device to the obturator nerve was 4.23 cm. In 19 cases out of 22 the anchor was within the complex of the obturator membrane and obturator muscles. In the group of fresh frozen bodies the mean distance to the obturator nerve was 3.15 cm. In 9 cases out of 10 the anchor was in the complex of the obturator membrane and obturator muscles. CONCLUSION: The distance from the anchor to the obturator nerve was more than 2 cm in all cases. Correct placement in the obturator membrane was achieved in 65.6 % of cases. In 87.5 % of cases the anchor was placed within the complex of obturator membrane and obturator muscles.
- 650 _2
- $a mrtvola $7 D002102
- 650 _2
- $a kryoprezervace $7 D015925
- 650 _2
- $a disekce $7 D004210
- 650 _2
- $a balzamování $7 D004615
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a nervus obturatorius $x anatomie a histologie $7 D009776
- 650 _2
- $a polohování pacienta $7 D056888
- 650 _2
- $a pánev $x anatomie a histologie $7 D010388
- 650 _2
- $a implantace protézy $x metody $7 D019919
- 650 12
- $a retence protézy $7 D060489
- 650 12
- $a suburetrální pásky $7 D053825
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Naňka, Ondřej, $d 1972- $7 mzk2006348905
- 700 1_
- $a Martan, Alois, $d 1952- $7 nlk20010103172
- 700 1_
- $a Švabík, Kamil $7 xx0061005
- 700 1_
- $a El-Haddad, Rachid $7 xx0093282
- 700 1_
- $a Mašata, Jaromír, $d 1969- $7 mzk2004250988
- 773 0_
- $w MED00002395 $t International urogynecology journal $x 1433-3023 $g Roč. 24, č. 12 (2013), s. 2119-2123
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/23749242 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20141006 $b ABA008
- 991 __
- $a 20181012080744 $b ABA008
- 999 __
- $a ok $b bmc $g 1042607 $s 873636
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2013 $b 24 $c 12 $d 2119-2123 $i 1433-3023 $m International urogynecology journal $n Int. urogynecol. j. (Print) $x MED00002395
- GRA __
- $a NT14162 $p MZ0
- LZP __
- $a Pubmed-20141006