Je něco špatně v tomto záznamu ?
Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice
A. Bezrouk, L. Balsky, M. Smutny, I. Selke Krulichova, J. Zahora, J. Hanus, TR. Meling,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
- MeSH
- analýza zatížení zubů přístrojové vybavení MeSH
- lidé MeSH
- mechanické jevy MeSH
- mechanický stres MeSH
- nikl chemie MeSH
- nízká teplota MeSH
- ortodontické dráty * MeSH
- pružnost MeSH
- termodynamika MeSH
- testování materiálů MeSH
- titan chemie MeSH
- torze mechanická MeSH
- vysoká teplota MeSH
- zubní slitiny chemie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
INTRODUCTION: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. METHODS: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. RESULTS: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. CONCLUSIONS: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any preactivation, and they might cause persistently high loads and possibly overloading. Only springs with minor hysteresis, low temperature dependence of force, and a clinically useful plateau have the following clinical advantages: reduced chair time, optimal rates of tooth movement, reproducible clinical results, and conservation of anchorage.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15007942
- 003
- CZ-PrNML
- 005
- 20241120091956.0
- 007
- ta
- 008
- 150306s2014 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.ajodo.2014.05.025 $2 doi
- 035 __
- $a (PubMed)25172254
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Bezrouk, Ales $u Assistant professor, Department of Medical Biophysics, Charles University, Prague, Faculty of Medicine, Hradec Kralove, Czech Republic. Electronic address: bezrouka@lfhk.cuni.cz.
- 245 10
- $a Thermomechanical properties of nickel-titanium closed-coil springs and their implications for clinical practice / $c A. Bezrouk, L. Balsky, M. Smutny, I. Selke Krulichova, J. Zahora, J. Hanus, TR. Meling,
- 520 9_
- $a INTRODUCTION: The aim was to study nickel-titanium closed-coil springs in a clinically relevant test setting with respect to the accuracy of the "preactivation" for nickel-titanium closed-coil springs application and whether it is possible to keep activation forces constant during the whole time of treatment. METHODS: We tested 10 types of springs from 5 manufacturers under clinically relevant conditions, allowing us to study the interactions between load and temperature over time. Hystereses were compared using t tests. RESULTS: Springs with a large mechanical hysteresis also showed a large thermal hysteresis. After heating shock, these springs showed intensive force spikes and persistent high loads. Some springs showed negligible thermal and mechanical hysteresis. Such springs never showed any clinically significant persistent high loads. CONCLUSIONS: Springs with a large hysteresis were unable to keep activation forces constant during the whole time of treatment even after any preactivation, and they might cause persistently high loads and possibly overloading. Only springs with minor hysteresis, low temperature dependence of force, and a clinically useful plateau have the following clinical advantages: reduced chair time, optimal rates of tooth movement, reproducible clinical results, and conservation of anchorage.
- 650 _2
- $a nízká teplota $7 D003080
- 650 _2
- $a zubní slitiny $x chemie $7 D003722
- 650 _2
- $a analýza zatížení zubů $x přístrojové vybavení $7 D003799
- 650 _2
- $a pružnost $7 D004548
- 650 _2
- $a vysoká teplota $7 D006358
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a testování materiálů $7 D008422
- 650 _2
- $a mechanické jevy $7 D055595
- 650 _2
- $a nikl $x chemie $7 D009532
- 650 12
- $a ortodontické dráty $7 D009969
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a termodynamika $7 D013816
- 650 _2
- $a titan $x chemie $7 D014025
- 650 _2
- $a torze mechanická $7 D054159
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Balský, Libor $u Private practice, Hradec Kralove, Czech Republic. $7 xx0324717
- 700 1_
- $a Smutný, Martin, $u Postgraduate student, Department of Medical Biophysics, Charles University, Prague, Faculty of Medicine, Hradec Kralove, Czech Republic. $d 1989- $7 xx0300942
- 700 1_
- $a Selke Krulichova, Iva $u Assistant professor, Department of Medical Biophysics, Charles University, Prague, Faculty of Medicine, Hradec Kralove, Czech Republic.
- 700 1_
- $a Zahora, Jiri $u Assistant professor, Department of Medical Biophysics, Charles University, Prague, Faculty of Medicine, Hradec Kralove, Czech Republic.
- 700 1_
- $a Hanus, Josef $u Associate professor and chair, Department of Medical Biophysics, Charles University, Prague, Faculty of Medicine, Hradec Kralove, Czech Republic.
- 700 1_
- $a Meling, Torstein R $u Head, Department of Neurosurgery, National Hospital, Oslo, Norway.
- 773 0_
- $w MED00000274 $t American journal of orthodontics and dentofacial orthopedics $x 0889-5406 $g Roč. 146, č. 3 (2014), s. 319-27
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25172254 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150306 $b ABA008
- 991 __
- $a 20241120091951 $b ABA008
- 999 __
- $a ok $b bmc $g 1065215 $s 890742
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 146 $c 3 $d 319-27 $i 0889-5406 $m American journal of orthodontics and dentofacial orthopedics $n Am J Orthod Dentofacial Orthop $x MED00000274
- LZP __
- $a Pubmed-20150306