Storage effect on the analysis of pharmaceuticals and personal care products in wastewater

G. Fedorova, O. Golovko, T. Randak, R. Grabic,

. 2014 ; 111 (-) : 55-60.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc15007996

In this study, the stability of 124 target analytes in influent and effluent wastewater samples during short-term (4°C) and long-term (-18°C) storage was assessed. The most common storage scenario was considered, in which samples were frozen immediately after sampling without any pre-treatment. During short-term storage more analytes remained stable (concentration during storage was in the range of 60-120% of the initial concentration) at 4°C than at -18°C. During long-term storage (-18°C), three types of behavior were observed: constant concentrations throughout the experimental period, decreasing concentrations with time, and loss of the compound from the sample after freezing. Differences between effluent and influent samples were observed for 50 out of 124 tested PPCPs. The amount of stable analytes decreased with time during long-term storage. 72% and 56% of the target compounds in the effluent and influent wastewater, respectively, remained stable during 60days of storage. The number of stable compounds decreased to 57 (46%) and 46 (37%) in the effluent and influent, respectively, over 120days. 15 Pharmaceuticals were lost after freezing/thawing cycle. The results stress the importance of storage factors during analysis of pharmaceuticals in wastewater. The stability of target compounds in the samples under the planned storage conditions should be checked before starting the experiment to obtain reliable data.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15007996
003      
CZ-PrNML
005      
20150306132801.0
007      
ta
008      
150306s2014 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.chemosphere.2014.02.067 $2 doi
035    __
$a (PubMed)24997900
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Fedorova, Ganna $u University of South Bohemia in Ceske Budejovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Research Institute of Fish Culture and Hydrobiology, Zátiší 728/II, 389 25 Vodňany, Czech Republic. Electronic address: gfedorova@frov.jcu.cz.
245    10
$a Storage effect on the analysis of pharmaceuticals and personal care products in wastewater / $c G. Fedorova, O. Golovko, T. Randak, R. Grabic,
520    9_
$a In this study, the stability of 124 target analytes in influent and effluent wastewater samples during short-term (4°C) and long-term (-18°C) storage was assessed. The most common storage scenario was considered, in which samples were frozen immediately after sampling without any pre-treatment. During short-term storage more analytes remained stable (concentration during storage was in the range of 60-120% of the initial concentration) at 4°C than at -18°C. During long-term storage (-18°C), three types of behavior were observed: constant concentrations throughout the experimental period, decreasing concentrations with time, and loss of the compound from the sample after freezing. Differences between effluent and influent samples were observed for 50 out of 124 tested PPCPs. The amount of stable analytes decreased with time during long-term storage. 72% and 56% of the target compounds in the effluent and influent wastewater, respectively, remained stable during 60days of storage. The number of stable compounds decreased to 57 (46%) and 46 (37%) in the effluent and influent, respectively, over 120days. 15 Pharmaceuticals were lost after freezing/thawing cycle. The results stress the importance of storage factors during analysis of pharmaceuticals in wastewater. The stability of target compounds in the samples under the planned storage conditions should be checked before starting the experiment to obtain reliable data.
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a kosmetické přípravky $x analýza $x chemie $7 D003358
650    _2
$a zmrazování $7 D005615
650    _2
$a léčivé přípravky $x analýza $x chemie $7 D004364
650    _2
$a tandemová hmotnostní spektrometrie $7 D053719
650    _2
$a teplota $7 D013696
650    _2
$a časové faktory $7 D013997
650    _2
$a odpad tekutý - odstraňování $7 D014865
650    _2
$a odpadní voda $x chemie $7 D062065
650    _2
$a chemické látky znečišťující vodu $x analýza $x chemie $7 D014874
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Golovko, Oksana $u University of South Bohemia in Ceske Budejovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Research Institute of Fish Culture and Hydrobiology, Zátiší 728/II, 389 25 Vodňany, Czech Republic.
700    1_
$a Randak, Tomas $u University of South Bohemia in Ceske Budejovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Research Institute of Fish Culture and Hydrobiology, Zátiší 728/II, 389 25 Vodňany, Czech Republic.
700    1_
$a Grabic, Roman $u University of South Bohemia in Ceske Budejovice, Faculty of Fisheries and Protection of Waters, South Bohemian Research Center of Aquaculture and Biodiversity of Hydrocenoses, Research Institute of Fish Culture and Hydrobiology, Zátiší 728/II, 389 25 Vodňany, Czech Republic.
773    0_
$w MED00002124 $t Chemosphere $x 1879-1298 $g Roč. 111, č. - (2014), s. 55-60
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24997900 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150306 $b ABA008
991    __
$a 20150306133032 $b ABA008
999    __
$a ok $b bmc $g 1065269 $s 890796
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 111 $c - $d 55-60 $i 1879-1298 $m Chemosphere $n Chemosphere $x MED00002124
LZP    __
$a Pubmed-20150306

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...