Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Validation of FLOTAC for the detection and quantification of Troglodytella abrassarti and Neobalantidium coli in chimpanzees and pigs

M. Růžicová, KJ. Petrželková, B. Kalousová, D. Modrý, K. Pomajbíková,

. 2014 ; 100 (5) : 662-70.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem, validační studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc15008038
E-zdroje Online Plný text

NLK ProQuest Central od 2000-12-01 do 2023-12-31
Medline Complete (EBSCOhost) od 2007-06-01 do Před 6 měsíci
Health & Medicine (ProQuest) od 2000-12-01 do 2023-12-31
Public Health Database (ProQuest) od 2000-12-01 do 2023-12-31

We carried out a calibration of FLOTAC for ciliates Troglodytella abrassarti and Neobalantidium coli based on the selection of a most appropriate flotation solutions, and we also tested its accuracy (i.e., number of detected stages out of known added number of stages to fecal samples) and sensitivity for trophozoites of both ciliates in chimpanzee feces and N. coli cysts in pig feces, compared the detection threshold of FLOTAC with MIF-based sedimentation, and, subsequently, tested the losses of ciliate stages during sample preparation. Nine flotation solutions were evaluated, and ZnSO4 solution (specific gravity [s.g.] 1.2) showed to be the most suitable for trophozoite detection, while Sheather's solution (s.g. 1.33) was selected as most suitable for cysts. The FLOTAC sensitivity in detection of both stages varied: for trophozoites, we found all samples were positive when the intensity of infection 10 trophozoites per gram and higher, whereas for cysts the sensitivity was lower. The accuracy of FLOTAC negatively correlated with infection intensity, and the merthiolate-iodine-formaldehyde sedimentation-based quantification had a lower detection threshold. We demonstrated additional losses of stages of T. abrassarti and N. coli due to their retention in the sediment, which is probably a major reason for discrepancies in the numbers of countable ciliates between both methods. In conclusion, the FLOTAC should not be considered as a gold standard for quantification of intestinal ciliates in primates; instead, we recommend the modified MIF method.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15008038
003      
CZ-PrNML
005      
20150401085105.0
007      
ta
008      
150306s2014 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1645/14-505.1 $2 doi
035    __
$a (PubMed)24870981
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Růžicová, M $u Department of Pathology and Parasitology, Faculty of Veterinary Medicine, University of Veterinary and Pharmaceutical Sciences, Palackého 1-3, 612 42 Brno, Czech Republic.
245    10
$a Validation of FLOTAC for the detection and quantification of Troglodytella abrassarti and Neobalantidium coli in chimpanzees and pigs / $c M. Růžicová, KJ. Petrželková, B. Kalousová, D. Modrý, K. Pomajbíková,
520    9_
$a We carried out a calibration of FLOTAC for ciliates Troglodytella abrassarti and Neobalantidium coli based on the selection of a most appropriate flotation solutions, and we also tested its accuracy (i.e., number of detected stages out of known added number of stages to fecal samples) and sensitivity for trophozoites of both ciliates in chimpanzee feces and N. coli cysts in pig feces, compared the detection threshold of FLOTAC with MIF-based sedimentation, and, subsequently, tested the losses of ciliate stages during sample preparation. Nine flotation solutions were evaluated, and ZnSO4 solution (specific gravity [s.g.] 1.2) showed to be the most suitable for trophozoite detection, while Sheather's solution (s.g. 1.33) was selected as most suitable for cysts. The FLOTAC sensitivity in detection of both stages varied: for trophozoites, we found all samples were positive when the intensity of infection 10 trophozoites per gram and higher, whereas for cysts the sensitivity was lower. The accuracy of FLOTAC negatively correlated with infection intensity, and the merthiolate-iodine-formaldehyde sedimentation-based quantification had a lower detection threshold. We demonstrated additional losses of stages of T. abrassarti and N. coli due to their retention in the sediment, which is probably a major reason for discrepancies in the numbers of countable ciliates between both methods. In conclusion, the FLOTAC should not be considered as a gold standard for quantification of intestinal ciliates in primates; instead, we recommend the modified MIF method.
650    _2
$a zvířata $7 D000818
650    _2
$a nemoci lidoopů $x diagnóza $x parazitologie $7 D018420
650    _2
$a kalibrace $7 D002138
650    _2
$a Ciliophora $x izolace a purifikace $7 D016798
650    _2
$a infekce prvoky kmene Ciliophora $x diagnóza $x parazitologie $x veterinární $7 D016770
650    _2
$a feces $x parazitologie $7 D005243
650    _2
$a limita detekce $7 D057230
650    _2
$a Pan troglodytes $x parazitologie $7 D002679
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a roztoky $x chemie $x klasifikace $7 D012996
650    _2
$a specifická hustota $7 D013046
650    _2
$a prasata $7 D013552
650    _2
$a nemoci prasat $x diagnóza $x parazitologie $7 D013553
655    _2
$a srovnávací studie $7 D003160
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
655    _2
$a validační studie $7 D023361
700    1_
$a Petrželková, K J
700    1_
$a Kalousová, B
700    1_
$a Modrý, D
700    1_
$a Pomajbíková, K
773    0_
$w MED00002876 $t The Journal of parasitology $x 1937-2345 $g Roč. 100, č. 5 (2014), s. 662-70
856    41
$u https://pubmed.ncbi.nlm.nih.gov/24870981 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150306 $b ABA008
991    __
$a 20150401085335 $b ABA008
999    __
$a ok $b bmc $g 1065311 $s 890838
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 100 $c 5 $d 662-70 $i 1937-2345 $m The Journal of parasitology $n J Parasitol $x MED00002876
LZP    __
$a Pubmed-20150306

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...