-
Something wrong with this record ?
Preconcentration based on paramagnetic microparticles for the separation of sarcosine using hydrophilic interaction liquid chromatography coupled with coulometric detection
O. Zitka, Z. Heger, M. Kominkova, S. Skalickova, S. Krizkova, V. Adam, R. Kizek,
Language English Country Germany
Document type Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Chromatography, Liquid instrumentation methods MeSH
- Hydrophobic and Hydrophilic Interactions MeSH
- Humans MeSH
- Magnetics MeSH
- Sarcosine isolation & purification urine MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
Sarcosine has been identified as a potential prostate cancer marker. To provide determination of this compound, a number of methods are developing. In this study, we optimized a method for its separation by hydrophilic interaction LC with electrochemical detection (ED). Due to the fact that mobile phases commonly used for this type of separation altered the LODs measured by electrochemical detectors, we applied postcolumn dosing of buffer suitable for ED. The optimized conditions were mobile phase A acetonitrile, mobile phase B water in the ratio A/B 70:30, with postcolumn addition of mobile phase C (200 mM phosphate buffer pH 9). The optimal mixing ratio was A + B/C 1:1 with a flow rate of 0.80 mL/min (0.40 + 0.40 mL/min) and detection potential of 1000 mV. Due to the optimization of the parameters for effective separation, which had to meet the optimal parameters of ED, we reached a good resolution for separation also with a good LOD (100 nM). In addition, we successfully carried out sarcosine analysis bound on our modified paramagnetic microparticles with the ability to preconcentrate sarcosine isolated from artificial urine.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15008432
- 003
- CZ-PrNML
- 005
- 20150330115221.0
- 007
- ta
- 008
- 150306s2014 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jssc.201301188 $2 doi
- 035 __
- $a (PubMed)24375951
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Zitka, Ondrej $u Department of Chemistry and Biochemistry, Faculty of Agronomy, Mendel University in Brno, Brno, Czech Republic; Central European Institute of Technology, Brno University of Technology, Brno, Czech Republic.
- 245 10
- $a Preconcentration based on paramagnetic microparticles for the separation of sarcosine using hydrophilic interaction liquid chromatography coupled with coulometric detection / $c O. Zitka, Z. Heger, M. Kominkova, S. Skalickova, S. Krizkova, V. Adam, R. Kizek,
- 520 9_
- $a Sarcosine has been identified as a potential prostate cancer marker. To provide determination of this compound, a number of methods are developing. In this study, we optimized a method for its separation by hydrophilic interaction LC with electrochemical detection (ED). Due to the fact that mobile phases commonly used for this type of separation altered the LODs measured by electrochemical detectors, we applied postcolumn dosing of buffer suitable for ED. The optimized conditions were mobile phase A acetonitrile, mobile phase B water in the ratio A/B 70:30, with postcolumn addition of mobile phase C (200 mM phosphate buffer pH 9). The optimal mixing ratio was A + B/C 1:1 with a flow rate of 0.80 mL/min (0.40 + 0.40 mL/min) and detection potential of 1000 mV. Due to the optimization of the parameters for effective separation, which had to meet the optimal parameters of ED, we reached a good resolution for separation also with a good LOD (100 nM). In addition, we successfully carried out sarcosine analysis bound on our modified paramagnetic microparticles with the ability to preconcentrate sarcosine isolated from artificial urine.
- 650 _2
- $a chromatografie kapalinová $x přístrojové vybavení $x metody $7 D002853
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a magnetismus $7 D008280
- 650 _2
- $a sarkosin $x izolace a purifikace $x moč $7 D012521
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Heger, Zbynek
- 700 1_
- $a Kominkova, Marketa
- 700 1_
- $a Skalickova, Sylvie
- 700 1_
- $a Krizkova, Sona
- 700 1_
- $a Adam, Vojtěch $7 xx0064599
- 700 1_
- $a Kizek, Rene
- 773 0_
- $w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 37, č. 5 (2014), s. 465-575
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24375951 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150306 $b ABA008
- 991 __
- $a 20150330115449 $b ABA008
- 999 __
- $a ok $b bmc $g 1065705 $s 891232
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 37 $c 5 $d 465-575 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
- LZP __
- $a Pubmed-20150306