Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Stanovení iopromidu a iopamidolu ve vodách metodou HPLC-MS-MS s využitím on-line prekoncentrace a kolon s porézním grafitickým uhlíkem
[HPLC-MS determination of iopromide and iopamidol in waters using on-line preconcentration in porous graphite columns]

Jiří Kokšal, Romana Beranová

. 2014 ; 108 (10) : 976-979.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc15008809

Determination of Iopromide and Iopamidole in surface and waste waters was developed. A porous graphitic carbon sorbent was used for pre-concentration and separation of analytes, in combination with tandem mass spectrometry as detection technique. The method was validated and applied in routine analyses. Its characteristics such as repeatability, limits of detection and determination are presented together with evaluation of matrix effects. The working range was 20–1000 ng L–1, limit of determination 20 ng L–1 and expanded uncertainty 30 %.

HPLC-MS determination of iopromide and iopamidol in waters using on-line preconcentration in porous graphite columns

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc15008809
003      
CZ-PrNML
005      
20150511104303.0
007      
ta
008      
150507s2014 xr ad f 000 0|cze||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Kokšal, Jiří $7 _AN081793 $u Povodí Ohře, s.p., Odbor vodohospodářských laboratoří, oddělení speciální organické analýzy, Novosedlická 758, 415 01 Teplice
245    10
$a Stanovení iopromidu a iopamidolu ve vodách metodou HPLC-MS-MS s využitím on-line prekoncentrace a kolon s porézním grafitickým uhlíkem / $c Jiří Kokšal, Romana Beranová
246    31
$a HPLC-MS determination of iopromide and iopamidol in waters using on-line preconcentration in porous graphite columns
504    __
$a Literatura
520    9_
$a Determination of Iopromide and Iopamidole in surface and waste waters was developed. A porous graphitic carbon sorbent was used for pre-concentration and separation of analytes, in combination with tandem mass spectrometry as detection technique. The method was validated and applied in routine analyses. Its characteristics such as repeatability, limits of detection and determination are presented together with evaluation of matrix effects. The working range was 20–1000 ng L–1, limit of determination 20 ng L–1 and expanded uncertainty 30 %.
650    12
$a chemické látky znečišťující vodu $x analýza $7 D014874
650    12
$a kontrastní látky $x analýza $7 D003287
650    _2
$a johexol $x analogy a deriváty $x analýza $7 D007472
650    _2
$a kyseliny trijodbenzoové $x analýza $x chemie $7 D014283
650    _2
$a kyselina jothalamová $x analogy a deriváty $x analýza $x chemie $7 D007483
650    12
$a chemické techniky analytické $7 D002623
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a hmotnostní spektrometrie $7 D013058
650    _2
$a referenční standardy $7 D012015
650    _2
$a testování odbornosti laboratoří $7 D059021
700    1_
$a Beranová, Romana $7 _AN081794 $u Povodí Ohře, s.p., Odbor vodohospodářských laboratoří, oddělení speciální organické analýzy, Novosedlická 758, 415 01 Teplice
773    0_
$t Chemické listy $x 0009-2770 $g Roč. 108, č. 10 (2014), s. 976-979 $w MED00011010
856    41
$u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/453/453 $y domovská stránka časopisu - plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 4 $z 0
990    __
$a 20150507080354 $b ABA008
991    __
$a 20150511104612 $b ABA008
999    __
$a ok $b bmc $g 1066082 $s 891610
BAS    __
$a 3
BMC    __
$a 2014 $b 108 $c 10 $d 976-979 $i 0009-2770 $m Chemické listy $n Chem. Listy $x MED00011010
LZP    __
$c NLK137 $d 20150511 $a NLK 2015-12/vt

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...