Intra-breath arterial oxygen oscillations detected by a fast oxygen sensor in an animal model of acute respiratory distress syndrome
F. Formenti, R. Chen, H. McPeak, PJ. Murison, M. Matejovic, CE. Hahn, AD. Farmery,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Open Access Digital Library
od 1995-01-01 do Před 12 měsíci
Elsevier Open Access Journals
od 1923-07-01 do Před 1 rokem
Elsevier Open Archive Journals
od 1923-07-01 do Před 1 rokem
PubMed
25631471
DOI
10.1093/bja/aeu407
Knihovny.cz E-zdroje
- MeSH
- kyslík krev MeSH
- modely nemocí na zvířatech MeSH
- prasata MeSH
- syndrom dechové tísně krev MeSH
- technologie optických vláken MeSH
- zvířata MeSH
- Check Tag
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: There is considerable interest in oxygen partial pressure (Po2) monitoring in physiology, and in tracking Po2 changes dynamically when it varies rapidly. For example, arterial Po2 ([Formula: see text]) can vary within the respiratory cycle in cyclical atelectasis (CA), where [Formula: see text] is thought to increase and decrease during inspiration and expiration, respectively. A sensor that detects these [Formula: see text] oscillations could become a useful diagnostic tool of CA during acute respiratory distress syndrome (ARDS). METHODS: We developed a fibreoptic Po2 sensor (<200 µm diameter), suitable for human use, that has a fast response time, and can measure Po2 continuously in blood. By altering the inspired fraction of oxygen ([Formula: see text]) from 21 to 100% in four healthy animal models, we determined the linearity of the sensor's signal over a wide range of [Formula: see text] values in vivo. We also hypothesized that the sensor could measure rapid intra-breath [Formula: see text] oscillations in a large animal model of ARDS. RESULTS: In the healthy animal models, [Formula: see text] responses to changes in [Formula: see text] were in agreement with conventional intermittent blood-gas analysis (n=39) for a wide range of [Formula: see text] values, from 10 to 73 kPa. In the animal lavage model of CA, the sensor detected [Formula: see text] oscillations, also at clinically relevant [Formula: see text] levels close to 9 kPa. CONCLUSIONS: We conclude that these fibreoptic [Formula: see text] sensors have the potential to become a diagnostic tool for CA in ARDS.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15022844
- 003
- CZ-PrNML
- 005
- 20150729121340.0
- 007
- ta
- 008
- 150709s2015 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1093/bja/aeu407 $2 doi
- 035 __
- $a (PubMed)25631471
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Formenti, F $u Nuffield Department of Clinical Neurosciences, Nuffield Division of Anaesthetics, University of Oxford, Oxford, UK federico.formenti@ndcn.ox.ac.uk.
- 245 10
- $a Intra-breath arterial oxygen oscillations detected by a fast oxygen sensor in an animal model of acute respiratory distress syndrome / $c F. Formenti, R. Chen, H. McPeak, PJ. Murison, M. Matejovic, CE. Hahn, AD. Farmery,
- 520 9_
- $a BACKGROUND: There is considerable interest in oxygen partial pressure (Po2) monitoring in physiology, and in tracking Po2 changes dynamically when it varies rapidly. For example, arterial Po2 ([Formula: see text]) can vary within the respiratory cycle in cyclical atelectasis (CA), where [Formula: see text] is thought to increase and decrease during inspiration and expiration, respectively. A sensor that detects these [Formula: see text] oscillations could become a useful diagnostic tool of CA during acute respiratory distress syndrome (ARDS). METHODS: We developed a fibreoptic Po2 sensor (<200 µm diameter), suitable for human use, that has a fast response time, and can measure Po2 continuously in blood. By altering the inspired fraction of oxygen ([Formula: see text]) from 21 to 100% in four healthy animal models, we determined the linearity of the sensor's signal over a wide range of [Formula: see text] values in vivo. We also hypothesized that the sensor could measure rapid intra-breath [Formula: see text] oscillations in a large animal model of ARDS. RESULTS: In the healthy animal models, [Formula: see text] responses to changes in [Formula: see text] were in agreement with conventional intermittent blood-gas analysis (n=39) for a wide range of [Formula: see text] values, from 10 to 73 kPa. In the animal lavage model of CA, the sensor detected [Formula: see text] oscillations, also at clinically relevant [Formula: see text] levels close to 9 kPa. CONCLUSIONS: We conclude that these fibreoptic [Formula: see text] sensors have the potential to become a diagnostic tool for CA in ARDS.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a technologie optických vláken $7 D005336
- 650 _2
- $a kyslík $x krev $7 D010100
- 650 _2
- $a syndrom dechové tísně $x krev $7 D012128
- 650 _2
- $a prasata $7 D013552
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Chen, R $u Nuffield Department of Clinical Neurosciences, Nuffield Division of Anaesthetics, University of Oxford, Oxford, UK.
- 700 1_
- $a McPeak, H $u Nuffield Department of Clinical Neurosciences, Nuffield Division of Anaesthetics, University of Oxford, Oxford, UK.
- 700 1_
- $a Murison, P J $u School of Veterinary Sciences, University of Bristol, Bristol, UK.
- 700 1_
- $a Matejovic, M $u Biomedical Centre, Charles University in Prague, Faculty of Medicine in Pilsen, alej Svobody 80, 304 60 Pilsen, Czech Republic First Medical Department, Charles University in Prague, Faculty of Medicine in Pilsen, alej Svobody 80, 304 60 Pilsen, Czech Republic.
- 700 1_
- $a Hahn, C E W $u Nuffield Department of Clinical Neurosciences, Nuffield Division of Anaesthetics, University of Oxford, Oxford, UK.
- 700 1_
- $a Farmery, A D $u Nuffield Department of Clinical Neurosciences, Nuffield Division of Anaesthetics, University of Oxford, Oxford, UK.
- 773 0_
- $w MED00000855 $t British journal of anaesthesia $x 1471-6771 $g Roč. 114, č. 4 (2015), s. 683-8
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25631471 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150729121427 $b ABA008
- 999 __
- $a ok $b bmc $g 1083183 $s 905837
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 114 $c 4 $d 683-8 $i 1471-6771 $m British Journal of Anaesthesia $n Br J Anaesth $x MED00000855
- LZP __
- $a Pubmed-20150709