In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay
R. Suárez, B. Horstkotte, V. Cerdà,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't
- MeSH
- Automation * MeSH
- Biological Assay methods MeSH
- Water Pollutants, Chemical analysis MeSH
- Syringes MeSH
- Limit of Detection MeSH
- Magnetics * MeSH
- Methylene Blue analysis MeSH
- Liquid Phase Microextraction methods MeSH
- Surface-Active Agents analysis MeSH
- Solvents chemistry MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3mg/L using only 200 µL of solvent and 4 mL of sample. The limits of detection (3σ) and quantification (10σ) were 7.0 µg/L and 22 µg/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023088
- 003
- CZ-PrNML
- 005
- 20150709122414.0
- 007
- ta
- 008
- 150709s2014 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2014.06.063 $2 doi
- 035 __
- $a (PubMed)25159446
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Suárez, Ruth $u Laboratory of Environmental Analytical Chemistry-LQA(2), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca, Spain.
- 245 10
- $a In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay / $c R. Suárez, B. Horstkotte, V. Cerdà,
- 520 9_
- $a A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3mg/L using only 200 µL of solvent and 4 mL of sample. The limits of detection (3σ) and quantification (10σ) were 7.0 µg/L and 22 µg/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent.
- 650 12
- $a automatizace $7 D001331
- 650 _2
- $a biotest $x metody $7 D001681
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a mikroextrakce kapalné fáze $x metody $7 D059627
- 650 12
- $a magnetismus $7 D008280
- 650 _2
- $a methylenová modř $x analýza $7 D008751
- 650 _2
- $a rozpouštědla $x chemie $7 D012997
- 650 _2
- $a povrchově aktivní látky $x analýza $7 D013501
- 650 _2
- $a injekční stříkačky $7 D013594
- 650 _2
- $a chemické látky znečišťující vodu $x analýza $7 D014874
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Horstkotte, Burkhard $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, CZ-50005 Hradec Králové, Czech Republic.
- 700 1_
- $a Cerdà, Victor $u Laboratory of Environmental Analytical Chemistry-LQA(2), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca, Spain. Electronic address: victor.cerda@uib.es.
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 130, č. - (2014), s. 555-60
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25159446 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150709122434 $b ABA008
- 999 __
- $a ok $b bmc $g 1083426 $s 906081
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 130 $c - $d 555-60 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20150709