In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay

R. Suárez, B. Horstkotte, V. Cerdà,

. 2014 ; 130 (-) : 555-60.

Language English Country Netherlands

Document type Journal Article, Research Support, Non-U.S. Gov't

A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3mg/L using only 200 µL of solvent and 4 mL of sample. The limits of detection (3σ) and quantification (10σ) were 7.0 µg/L and 22 µg/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15023088
003      
CZ-PrNML
005      
20150709122414.0
007      
ta
008      
150709s2014 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2014.06.063 $2 doi
035    __
$a (PubMed)25159446
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Suárez, Ruth $u Laboratory of Environmental Analytical Chemistry-LQA(2), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca, Spain.
245    10
$a In-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction for automation and downscaling of methylene blue active substances assay / $c R. Suárez, B. Horstkotte, V. Cerdà,
520    9_
$a A simple and rapid method for the determination of the methylene blue active substances assay based on in-syringe automation of magnetic stirring-assisted dispersive liquid-liquid microextraction was developed. The proposed method proved to be valid for the determination of anionic surfactant in waste, pond, well, tap, and drinking water samples. Sample mixing with reagents, extraction and phase separation were performed within the syringe of an automated syringe pump containing a magnetic stirring bar for homogenization and solvent dispersion. The syringe module was used upside-down to enable the use of chloroform as an extraction solvent of higher density than water. The calibration was found to be linear up to 0.3mg/L using only 200 µL of solvent and 4 mL of sample. The limits of detection (3σ) and quantification (10σ) were 7.0 µg/L and 22 µg/L, respectively. The relative standard deviation for 10 replicate determinations of 0.1mg/L SBDS was below 3%. Concentrations of anionic surfactants in natural water samples were in the range of 0.032-0.213 mg/L and no significant differences towards the standard method were found. Standard additions gave analyte recoveries between 95% and 106% proving the general applicability and adequateness of the system to MBSA index determination. Compared to the tedious standard method requiring up to 50 mL of chloroform, the entire procedure took only 345 s using 250-times less solvent.
650    12
$a automatizace $7 D001331
650    _2
$a biotest $x metody $7 D001681
650    _2
$a limita detekce $7 D057230
650    _2
$a mikroextrakce kapalné fáze $x metody $7 D059627
650    12
$a magnetismus $7 D008280
650    _2
$a methylenová modř $x analýza $7 D008751
650    _2
$a rozpouštědla $x chemie $7 D012997
650    _2
$a povrchově aktivní látky $x analýza $7 D013501
650    _2
$a injekční stříkačky $7 D013594
650    _2
$a chemické látky znečišťující vodu $x analýza $7 D014874
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Horstkotte, Burkhard $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovského 1203, CZ-50005 Hradec Králové, Czech Republic.
700    1_
$a Cerdà, Victor $u Laboratory of Environmental Analytical Chemistry-LQA(2), University of the Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca, Spain. Electronic address: victor.cerda@uib.es.
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 130, č. - (2014), s. 555-60
856    41
$u https://pubmed.ncbi.nlm.nih.gov/25159446 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20150709 $b ABA008
991    __
$a 20150709122434 $b ABA008
999    __
$a ok $b bmc $g 1083426 $s 906081
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 130 $c - $d 555-60 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20150709

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...