-
Something wrong with this record ?
Enzyme-linked electrochemical DNA ligation assay using magnetic beads
E. Stejskalová, P. Horáková, J. Vacek, RP. Bowater, M. Fojta,
Language English Country Germany
Document type Evaluation Study, Journal Article, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 2011-01-01 to 1 year ago
- MeSH
- DNA Ligases chemistry MeSH
- DNA chemistry MeSH
- Electrochemical Techniques instrumentation methods MeSH
- Enzyme Assays instrumentation methods MeSH
- Enzymes, Immobilized chemistry MeSH
- Escherichia coli chemistry enzymology MeSH
- Magnetics MeSH
- Escherichia coli Proteins chemistry MeSH
- Publication type
- Journal Article MeSH
- Evaluation Study MeSH
- Research Support, Non-U.S. Gov't MeSH
DNA ligases are essential enzymes in all cells and have been proposed as targets for novel antibiotics. Efficient DNA ligase activity assays are thus required for applications in biomedical research. Here we present an enzyme-linked electrochemical assay based on two terminally tagged probes forming a nicked junction upon hybridization with a template DNA. Nicked DNA bearing a 5' biotin tag is immobilized on the surface of streptavidin-coated magnetic beads, and ligated product is detected via a 3' digoxigenin tag recognized by monoclonal antibody-alkaline phosphatase conjugate. Enzymatic conversion of napht-1-yl phosphate to napht-1-ol enables sensitive detection of the voltammetric signal on a pyrolytic graphite electrode. The technique was tested under optimal conditions and various situations limiting or precluding the ligation reaction (such as DNA substrates lacking 5'-phosphate or containing a base mismatch at the nick junction, or application of incompatible cofactor), and utilized for the analysis of the nick-joining activity of a range of recombinant Escherichia coli DNA ligase constructs. The novel technique provides a fast, versatile, specific, and sensitive electrochemical assay of DNA ligase activity.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023416
- 003
- CZ-PrNML
- 005
- 20150709122327.0
- 007
- ta
- 008
- 150709s2014 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-014-7811-y $2 doi
- 035 __
- $a (PubMed)24820061
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Stejskalová, Eva $u Institute of Biophysics, v.v.i., Academy of Sciences of the Czech Republic, Královopolská 135, 612 65, Brno, Czech Republic.
- 245 10
- $a Enzyme-linked electrochemical DNA ligation assay using magnetic beads / $c E. Stejskalová, P. Horáková, J. Vacek, RP. Bowater, M. Fojta,
- 520 9_
- $a DNA ligases are essential enzymes in all cells and have been proposed as targets for novel antibiotics. Efficient DNA ligase activity assays are thus required for applications in biomedical research. Here we present an enzyme-linked electrochemical assay based on two terminally tagged probes forming a nicked junction upon hybridization with a template DNA. Nicked DNA bearing a 5' biotin tag is immobilized on the surface of streptavidin-coated magnetic beads, and ligated product is detected via a 3' digoxigenin tag recognized by monoclonal antibody-alkaline phosphatase conjugate. Enzymatic conversion of napht-1-yl phosphate to napht-1-ol enables sensitive detection of the voltammetric signal on a pyrolytic graphite electrode. The technique was tested under optimal conditions and various situations limiting or precluding the ligation reaction (such as DNA substrates lacking 5'-phosphate or containing a base mismatch at the nick junction, or application of incompatible cofactor), and utilized for the analysis of the nick-joining activity of a range of recombinant Escherichia coli DNA ligase constructs. The novel technique provides a fast, versatile, specific, and sensitive electrochemical assay of DNA ligase activity.
- 650 _2
- $a DNA $x chemie $7 D004247
- 650 _2
- $a DNA-ligasy $x chemie $7 D011088
- 650 _2
- $a elektrochemické techniky $x přístrojové vybavení $x metody $7 D055664
- 650 _2
- $a enzymatické testy $x přístrojové vybavení $x metody $7 D057075
- 650 _2
- $a enzymy imobilizované $x chemie $7 D004800
- 650 _2
- $a Escherichia coli $x chemie $x enzymologie $7 D004926
- 650 _2
- $a proteiny z Escherichia coli $x chemie $7 D029968
- 650 _2
- $a magnetismus $7 D008280
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Horáková, Petra
- 700 1_
- $a Vacek, Jan
- 700 1_
- $a Bowater, Richard P
- 700 1_
- $a Fojta, Miroslav
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 406, č. 17 (2014), s. 4129-36
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24820061 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150709122346 $b ABA008
- 999 __
- $a ok $b bmc $g 1083753 $s 906409
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 406 $c 17 $d 4129-36 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20150709