-
Je něco špatně v tomto záznamu ?
Study of the retention behavior of small polar molecules on different types of stationary phases used in hydrophilic interaction liquid chromatography
H. Vlčková, K. Ježková, K. Stětková, H. Tomšíková, P. Solich, L. Nováková,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
24648311
DOI
10.1002/jssc.201400020
Knihovny.cz E-zdroje
- MeSH
- chromatografie kapalinová přístrojové vybavení MeSH
- hydrofobní a hydrofilní interakce MeSH
- koncentrace vodíkových iontů MeSH
- organické látky chemie MeSH
- oxid křemičitý chemie MeSH
- poréznost MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The retention behavior of a large group of analytes (35) with varied properties (pKa and logP) was studied on eight hydrophilic interaction LC columns with different surfaces, stationary phase chemistries, and types of particles. The acetonitrile content (5-95%), buffer concentration (0.5-200 mM), and pH of the mobile phase (3.8 and 6.8) were evaluated for their effects on the retention behavior. The type of stationary phase had a significant impact on the selectivity and retention time of the tested analytes. Completely different selectivity was observed on the aminopropyl stationary phase. In this study, the influence of the buffer concentration was similar for all tested columns, except for the aminopropyl stationary phase. Increasing the buffer concentration led to decreased retention times for the basic compounds and increased retention times for the acidic compounds, while the inverse behavior was observed on the aminopropyl stationary phase. The selectivity of the individual stationary phases was evaluated at pH 3.8 and 6.8. Much lower selectivity differences between the stationary phases were observed at pH 6.8 than pH 3.8. Bare silica stationary phases were used in the comparison of the particles (fused-core and fully porous particles of 3 and 1.7 μm) and the columns provided by different manufacturers.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15023530
- 003
- CZ-PrNML
- 005
- 20150729101832.0
- 007
- ta
- 008
- 150709s2014 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jssc.201400020 $2 doi
- 035 __
- $a (PubMed)24648311
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Vlčková, Hana $u Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Hradec Králové, Czech Republic.
- 245 10
- $a Study of the retention behavior of small polar molecules on different types of stationary phases used in hydrophilic interaction liquid chromatography / $c H. Vlčková, K. Ježková, K. Stětková, H. Tomšíková, P. Solich, L. Nováková,
- 520 9_
- $a The retention behavior of a large group of analytes (35) with varied properties (pKa and logP) was studied on eight hydrophilic interaction LC columns with different surfaces, stationary phase chemistries, and types of particles. The acetonitrile content (5-95%), buffer concentration (0.5-200 mM), and pH of the mobile phase (3.8 and 6.8) were evaluated for their effects on the retention behavior. The type of stationary phase had a significant impact on the selectivity and retention time of the tested analytes. Completely different selectivity was observed on the aminopropyl stationary phase. In this study, the influence of the buffer concentration was similar for all tested columns, except for the aminopropyl stationary phase. Increasing the buffer concentration led to decreased retention times for the basic compounds and increased retention times for the acidic compounds, while the inverse behavior was observed on the aminopropyl stationary phase. The selectivity of the individual stationary phases was evaluated at pH 3.8 and 6.8. Much lower selectivity differences between the stationary phases were observed at pH 6.8 than pH 3.8. Bare silica stationary phases were used in the comparison of the particles (fused-core and fully porous particles of 3 and 1.7 μm) and the columns provided by different manufacturers.
- 650 _2
- $a chromatografie kapalinová $x přístrojové vybavení $7 D002853
- 650 _2
- $a koncentrace vodíkových iontů $7 D006863
- 650 _2
- $a hydrofobní a hydrofilní interakce $7 D057927
- 650 _2
- $a organické látky $x chemie $7 D009930
- 650 _2
- $a poréznost $7 D016062
- 650 _2
- $a oxid křemičitý $x chemie $7 D012822
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Ježková, Kateřina
- 700 1_
- $a Stětková, Kateřina
- 700 1_
- $a Tomšíková, Helena
- 700 1_
- $a Solich, Petr
- 700 1_
- $a Nováková, Lucie
- 773 0_
- $w MED00006463 $t Journal of separation science $x 1615-9314 $g Roč. 37, č. 11 (2014), s. 1297-307
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/24648311 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150709 $b ABA008
- 991 __
- $a 20150729101918 $b ABA008
- 999 __
- $a ok $b bmc $g 1083867 $s 906523
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 37 $c 11 $d 1297-307 $i 1615-9314 $m Journal of separation science $n J Sep Sci $x MED00006463
- LZP __
- $a Pubmed-20150709