-
Something wrong with this record ?
Mikroskopická analýza oxidativní degradace polyethylenových komponent kloubních náhrad
[Microscopic analysis of oxidative degradation of polyethylene components of total joint replacements]
Martina Nevoralová, Miroslav Šlouf, Jiří Dybal, Jana Kredatusová, Petr Fulín, David Pokorný
Language Czech Country Czech Republic
Document type Research Support, Non-U.S. Gov't
Grant support
NV15-31269A
MZ0
CEP Register
Digital library NLK
Full text - Article
NLK
ROAD: Directory of Open Access Scholarly Resources
from 1997
- MeSH
- Arthroplasty, Replacement MeSH
- Humans MeSH
- Microscopy methods MeSH
- Joint Instability MeSH
- Oxidation-Reduction MeSH
- Polyethylenes chemistry MeSH
- Joint Prosthesis MeSH
- Hardness Tests MeSH
- Check Tag
- Humans MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
Ultrahigh-molecular-weight polyethylene (UHMWPE) has been used as a liner in total joint replacements (TJR) since the 1970's. One of the main lifetime-limiting factors of contemporary TJRs is the long-term oxidative stability of UHMWPE, as the oxidative degradation results in chain scissions and deterioration of mechanical properties, including the most important one – wear resistance. In order to maximize the oxidation and wear resistance of UHMWPE components, the manufacturers apply various procedures, such as crosslinking by ionizing radiation, thermal treatment and stabilization. Almost each manufacturer uses its own UHMWPE modification procedure and there is a number of different types of UHMWPEs on the market. Clinical practice stressed the need for an objective comparison of different UHMWPE types and the influence of oxidative damage on the lifetime of TJR. Due to the small size and irregular shape of UHMWPE components and inhomogeneous nature of oxidative degradation in vivo, their properties should be studied by microscopic methods. We tested the sensitivity and accuracy of two microscopic methods – infrared microscopy (IR) and microhardness (MH) measurements supplemented by DSC in relation to UHMWPE characteristics. The methods help to analyze reasons for TJR failures, to detect differences in molecular and supramolecular structures and properties of various UHMWPE types, and to characterize aging of various UHMWPE components in vitro.
Microscopic analysis of oxidative degradation of polyethylene components of total joint replacements
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15024640
- 003
- CZ-PrNML
- 005
- 20240117103503.0
- 007
- ta
- 008
- 150720s2015 xr d f 000 0|cze||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Nevoralová, Martina $7 ntka173525 $u Ústav makromolekulární chemie AV ČR, Praha 6
- 245 10
- $a Mikroskopická analýza oxidativní degradace polyethylenových komponent kloubních náhrad / $c Martina Nevoralová, Miroslav Šlouf, Jiří Dybal, Jana Kredatusová, Petr Fulín, David Pokorný
- 246 31
- $a Microscopic analysis of oxidative degradation of polyethylene components of total joint replacements
- 504 __
- $a Literatura
- 520 9_
- $a Ultrahigh-molecular-weight polyethylene (UHMWPE) has been used as a liner in total joint replacements (TJR) since the 1970's. One of the main lifetime-limiting factors of contemporary TJRs is the long-term oxidative stability of UHMWPE, as the oxidative degradation results in chain scissions and deterioration of mechanical properties, including the most important one – wear resistance. In order to maximize the oxidation and wear resistance of UHMWPE components, the manufacturers apply various procedures, such as crosslinking by ionizing radiation, thermal treatment and stabilization. Almost each manufacturer uses its own UHMWPE modification procedure and there is a number of different types of UHMWPEs on the market. Clinical practice stressed the need for an objective comparison of different UHMWPE types and the influence of oxidative damage on the lifetime of TJR. Due to the small size and irregular shape of UHMWPE components and inhomogeneous nature of oxidative degradation in vivo, their properties should be studied by microscopic methods. We tested the sensitivity and accuracy of two microscopic methods – infrared microscopy (IR) and microhardness (MH) measurements supplemented by DSC in relation to UHMWPE characteristics. The methods help to analyze reasons for TJR failures, to detect differences in molecular and supramolecular structures and properties of various UHMWPE types, and to characterize aging of various UHMWPE components in vitro.
- 650 _2
- $a artroplastiky kloubů $7 D019643
- 650 _2
- $a protézy kloubů $7 D007595
- 650 _2
- $a polyethyleny $x chemie $7 D011095
- 650 _2
- $a oxidace-redukce $7 D010084
- 650 _2
- $a mikroskopie $x metody $7 D008853
- 650 _2
- $a testy tvrdosti $7 D006245
- 650 _2
- $a nestabilita kloubu $7 D007593
- 650 _2
- $a lidé $7 D006801
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šlouf, Miroslav, $d 1973- $7 xx0107048 $u Ústav makromolekulární chemie AV ČR, Praha 6
- 700 1_
- $a Dybal, Jiří $7 xx0312810 $u Ústav makromolekulární chemie AV ČR, Praha 6
- 700 1_
- $a Kredatusová, Jana $7 xx0240837 $u Ústav makromolekulární chemie AV ČR, Praha 6
- 700 1_
- $a Fulín, Petr $7 xx0231618 $u 1. Ortopedická klinika 1. LF UK a FN Motol, Praha 5
- 700 1_
- $a Pokorný, David, $d 1968- $7 jn20001103568 $u 1. Ortopedická klinika 1. LF UK a FN Motol, Praha 5
- 773 0_
- $t Chemické listy $x 0009-2770 $g Roč. 109, č. 5 (2015), s. 395-400 $w MED00011010
- 856 41
- $u http://www.chemicke-listy.cz/ojs3/index.php/chemicke-listy/article/view/376/376 $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 4 $z 0
- 990 __
- $a 20150720111420 $b ABA008
- 991 __
- $a 20240117103459 $b ABA008
- 999 __
- $a ok $b bmc $g 1084922 $s 907640
- BAS __
- $a 3
- BMC __
- $a 2015 $b 109 $c 5 $d 395-400 $i 0009-2770 $m Chemické listy $n Chem. Listy $x MED00011010
- GRA __
- $a NV15-31269A $p MZ0
- LZP __
- $c NLK137 $d 20150831 $a NLK 2015-16/mk