-
Je něco špatně v tomto záznamu ?
Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model
S. Fischer, C. Hirche, MA. Reichenberger, J. Kiefer, Y. Diehm, S. Mukundan, M. Alhefzi, EM. Bueno, U. Kneser, B. Pomahac,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 2006
Free Medical Journals
od 2006
Public Library of Science (PLoS)
od 2006
PubMed Central
od 2006
Europe PubMed Central
od 2006
ProQuest Central
od 2006-12-01
Open Access Digital Library
od 2006-10-01
Open Access Digital Library
od 2006-01-01
Open Access Digital Library
od 2006-01-01
Medline Complete (EBSCOhost)
od 2008-01-01
Nursing & Allied Health Database (ProQuest)
od 2006-12-01
Health & Medicine (ProQuest)
od 2006-12-01
Public Health Database (ProQuest)
od 2006-12-01
ROAD: Directory of Open Access Scholarly Resources
od 2006
- Publikační typ
- časopisecké články MeSH
PURPOSE: Capsular contracture is the most frequent long-term complication after implant-based breast reconstruction or augmentation. The aim of this study was to evaluate the impact of implant surface properties on fibrotic capsule formation in an animal model. MATERIALS AND METHODS: Twenty-four rats received 1 scaled down silicone implant each; 12 of the rats received implants with textured surfaces, and the other 12 received implants with smooth surfaces. After 60 and 120 days, rats in each group underwent 7-Tesla Magnetic Resonance Imaging (MRI) and high-resolution ultrasound (HR-US), and specimens of the capsules were acquired and used to measure capsule thickness through histology, collagen density through picro sirius red staining, and analyses of expression of pro-fibrotic and inflammatory genes (Collagen1-4, TGFb1, TGFb3, Smad3, IL4, IL10, IL13, CD68) through qRT-PCR. Furthermore, MRI data were processed to obtain capsule volume and implant surface area. RESULTS: On day 60, histology and HR-US showed that fibrotic capsules were significantly thicker in the textured implant group with respect to the smooth implant group (p<0.05). However, this difference did not persist on day 120 (p=0.56). Capsule thickness decreased significantly over the study period in both smooth and textured implant groups (p<0.05). Thickness measurements were substantiated by MRI analysis and volumes changed accordingly. Implant surface area did not vary between study dates, but it was different between implant types. On day 60, the density of collagen in the fibrotic capsules was significantly lower in the textured implant group with respect to the smooth group (p<0.05), but again this difference did not persist on day 120 (p=0.67). Collagen 1 and CD68 were respectively over- and under expressed in the textured implant group on day 60. Significant differences in the expression of other genes were not observed. CONCLUSION: Silicone implants with textured surfaces led to temporarily thicker but less dense fibrotic capsules compared with smooth surfaces. 7-Tesla MRI and HR-US are capable for non-invasive in-vivo assessment of capsular fibrosis in an animal model and can provide unique insights into the fibrotic process by 3D reconstruction and surface area measurement.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15026244
- 003
- CZ-PrNML
- 005
- 20210218120416.0
- 007
- ta
- 008
- 150804s2015 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1371/journal.pone.0132131 $2 doi
- 035 __
- $a (PubMed)26151888
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Fischer, Sebastian $u Department of Surgery, Division of Plastic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America; Department of Hand-, Plastic and Reconstructive Surgery, BG Clinic Ludwigshafen, University of Heidelberg, Ludwigshafen, Germany.
- 245 10
- $a Silicone Implants with Smooth Surfaces Induce Thinner but Denser Fibrotic Capsules Compared to Those with Textured Surfaces in a Rodent Model / $c S. Fischer, C. Hirche, MA. Reichenberger, J. Kiefer, Y. Diehm, S. Mukundan, M. Alhefzi, EM. Bueno, U. Kneser, B. Pomahac,
- 520 9_
- $a PURPOSE: Capsular contracture is the most frequent long-term complication after implant-based breast reconstruction or augmentation. The aim of this study was to evaluate the impact of implant surface properties on fibrotic capsule formation in an animal model. MATERIALS AND METHODS: Twenty-four rats received 1 scaled down silicone implant each; 12 of the rats received implants with textured surfaces, and the other 12 received implants with smooth surfaces. After 60 and 120 days, rats in each group underwent 7-Tesla Magnetic Resonance Imaging (MRI) and high-resolution ultrasound (HR-US), and specimens of the capsules were acquired and used to measure capsule thickness through histology, collagen density through picro sirius red staining, and analyses of expression of pro-fibrotic and inflammatory genes (Collagen1-4, TGFb1, TGFb3, Smad3, IL4, IL10, IL13, CD68) through qRT-PCR. Furthermore, MRI data were processed to obtain capsule volume and implant surface area. RESULTS: On day 60, histology and HR-US showed that fibrotic capsules were significantly thicker in the textured implant group with respect to the smooth implant group (p<0.05). However, this difference did not persist on day 120 (p=0.56). Capsule thickness decreased significantly over the study period in both smooth and textured implant groups (p<0.05). Thickness measurements were substantiated by MRI analysis and volumes changed accordingly. Implant surface area did not vary between study dates, but it was different between implant types. On day 60, the density of collagen in the fibrotic capsules was significantly lower in the textured implant group with respect to the smooth group (p<0.05), but again this difference did not persist on day 120 (p=0.67). Collagen 1 and CD68 were respectively over- and under expressed in the textured implant group on day 60. Significant differences in the expression of other genes were not observed. CONCLUSION: Silicone implants with textured surfaces led to temporarily thicker but less dense fibrotic capsules compared with smooth surfaces. 7-Tesla MRI and HR-US are capable for non-invasive in-vivo assessment of capsular fibrosis in an animal model and can provide unique insights into the fibrotic process by 3D reconstruction and surface area measurement.
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hirche, Christoph $u Department of Hand-, Plastic and Reconstructive Surgery, BG Clinic Ludwigshafen, University of Heidelberg, Ludwigshafen, Germany.
- 700 1_
- $a Reichenberger, Matthias A $u Ethianum, Clinic for Plastic and Reconstructive Surgery, Aesthetic and Preventive Medicine at Heidelberg University Hospital, Heidelberg, Germany.
- 700 1_
- $a Kiefer, Jurij $u Department of Hand-, Plastic and Reconstructive Surgery, BG Clinic Ludwigshafen, University of Heidelberg, Ludwigshafen, Germany.
- 700 1_
- $a Diehm, Yannick $u Department of Hand-, Plastic and Reconstructive Surgery, BG Clinic Ludwigshafen, University of Heidelberg, Ludwigshafen, Germany.
- 700 1_
- $a Mukundan, Srinivasan $u Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America.
- 700 1_
- $a Alhefzi, Muayyad $u Department of Surgery, Division of Plastic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America. $7 gn_A_00004147
- 700 1_
- $a Bueno, Ericka M $u Department of Surgery, Division of Plastic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America.
- 700 1_
- $a Kneser, Ulrich, $d 1972- $7 xx0224007 $u Department of Hand-, Plastic and Reconstructive Surgery, BG Clinic Ludwigshafen, University of Heidelberg, Ludwigshafen, Germany.
- 700 1_
- $a Pomahač, Bohdan, $u Department of Surgery, Division of Plastic Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, United States of America. $d 1971- $7 xx0117402
- 773 0_
- $w MED00180950 $t PloS one $x 1932-6203 $g Roč. 10, č. 7 (2015), s. e0132131
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/26151888 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20150804 $b ABA008
- 991 __
- $a 20210218120414 $b ABA008
- 999 __
- $a ind $b bmc $g 1086829 $s 909270
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 10 $c 7 $d e0132131 $e 20150707 $i 1932-6203 $m PLoS One $n PLoS One $x MED00180950
- LZP __
- $a Pubmed-20150804