Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Intra-scleral parathalamus implant: efficacy and safety in rabbit eyes

E. T. Detorakis, K. Loggaki, N. Karyotakis, H. Ginis

. 2014 ; 57 (4) : 151-156.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc15030954

PURPOSE: A variety of anti-glaucomatous shunt designs have been proposed so far. This study evaluates the feasibility of a novel shunt design, the intra-scleral parathalamus implant (IPI), in a rabbit eye model. METHODS: Ten healthy albino rabbits were included. Measurements of the IOP, using TonoPenXL, as well as ocular rigidity (OR) and aqueous outflow facility (AO), using a previously described methodology, were performed in both eyes of each animal. Subsequently, the IPI was implanted at the left eye of all animals whereas the right eye served as control. Measurements of IOP were repeated at weekly intervals for 2 months postoperatively whereas measurements of OR and AO were repeated at the 1st and 2nd postoperative week. RESULTS: The IOP decreased significantly whereas the AO increased significantly postoperatively at the operated eyes. A significant postoperative decrease in OR was also recorded at the operated eyes. Respective differences at the fellow eyes were statistically not significant. Two animals developed postoperative complications and were excluded from follow-up. CONCLUSIONS: Results imply that the implantation of the IPI is feasible in rabbit eyes with significant favorable effects on the IOP, AO and OR.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc15030954
003      
CZ-PrNML
005      
20151021152707.0
007      
ta
008      
151001s2014 xr ad f 000 0|eng||
009      
AR
024    7_
$a 10.14712/18059694.2015.80 $2 doi
035    __
$a (PubMed)25938898
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Detorakis, Efstathios T. $u Department of Ophthalmology, University Hospital of Heraklion, Greece; Institute of Vision & Optics, University of Crete, Greece
245    10
$a Intra-scleral parathalamus implant: efficacy and safety in rabbit eyes / $c E. T. Detorakis, K. Loggaki, N. Karyotakis, H. Ginis
520    9_
$a PURPOSE: A variety of anti-glaucomatous shunt designs have been proposed so far. This study evaluates the feasibility of a novel shunt design, the intra-scleral parathalamus implant (IPI), in a rabbit eye model. METHODS: Ten healthy albino rabbits were included. Measurements of the IOP, using TonoPenXL, as well as ocular rigidity (OR) and aqueous outflow facility (AO), using a previously described methodology, were performed in both eyes of each animal. Subsequently, the IPI was implanted at the left eye of all animals whereas the right eye served as control. Measurements of IOP were repeated at weekly intervals for 2 months postoperatively whereas measurements of OR and AO were repeated at the 1st and 2nd postoperative week. RESULTS: The IOP decreased significantly whereas the AO increased significantly postoperatively at the operated eyes. A significant postoperative decrease in OR was also recorded at the operated eyes. Respective differences at the fellow eyes were statistically not significant. Two animals developed postoperative complications and were excluded from follow-up. CONCLUSIONS: Results imply that the implantation of the IPI is feasible in rabbit eyes with significant favorable effects on the IOP, AO and OR.
650    _2
$a zvířata $7 D000818
650    _2
$a modely nemocí na zvířatech $7 D004195
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a glaukom $x chirurgie $7 D005901
650    _2
$a nitrooční tlak $7 D007429
650    12
$a protézy a implantáty $7 D019736
650    _2
$a králíci $7 D011817
650    _2
$a sklerostomie $x metody $7 D012599
655    _2
$a časopisecké články $7 D016428
700    1_
$a Loggaki, Konstantina $u Institute of Vision & Optics, University of Crete, Greece
700    1_
$a Karyotakis, Nikolaos $u Institute of Vision & Optics, University of Crete, Greece
700    1_
$a Ginis, Harilaos $u Institute of Vision & Optics, University of Crete, Greece
773    0_
$w MED00010947 $t Acta medica (Hradec Králové) Universitas Carolina, Facultas Medica Hradec Králové $x 1211-4286 $g Roč. 57, č. 4 (2014), s. 151-156
856    41
$u https://actamedica.lfhk.cuni.cz/media/pdf/am_2014057040151.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 3077 $c 1072 $y 4 $z 0
990    __
$a 20151001 $b ABA008
991    __
$a 20151019134544 $b ABA008
999    __
$a ok $b bmc $g 1094789 $s 914070
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2014 $b 57 $c 4 $d 151-156 $i 1211-4286 $m Acta Medica $n Acta Med. (Hradec Král.) $x MED00010947
LZP    __
$b NLK118 $a Pubmed-20151001

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...