-
Je něco špatně v tomto záznamu ?
Intra-scleral parathalamus implant: efficacy and safety in rabbit eyes
E. T. Detorakis, K. Loggaki, N. Karyotakis, H. Ginis
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
Digitální knihovna NLK
Plný text - Článek
Číslo
Ročník
Zdroj
Zdroj
NLK
Directory of Open Access Journals
od 1997
Free Medical Journals
od 1997
Open Access Digital Library
od 1997-01-01
Medline Complete (EBSCOhost)
od 2012-06-01
ROAD: Directory of Open Access Scholarly Resources
od 1997
- MeSH
- glaukom chirurgie MeSH
- králíci MeSH
- modely nemocí na zvířatech MeSH
- nitrooční tlak MeSH
- protézy a implantáty * MeSH
- sklerostomie metody MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: A variety of anti-glaucomatous shunt designs have been proposed so far. This study evaluates the feasibility of a novel shunt design, the intra-scleral parathalamus implant (IPI), in a rabbit eye model. METHODS: Ten healthy albino rabbits were included. Measurements of the IOP, using TonoPenXL, as well as ocular rigidity (OR) and aqueous outflow facility (AO), using a previously described methodology, were performed in both eyes of each animal. Subsequently, the IPI was implanted at the left eye of all animals whereas the right eye served as control. Measurements of IOP were repeated at weekly intervals for 2 months postoperatively whereas measurements of OR and AO were repeated at the 1st and 2nd postoperative week. RESULTS: The IOP decreased significantly whereas the AO increased significantly postoperatively at the operated eyes. A significant postoperative decrease in OR was also recorded at the operated eyes. Respective differences at the fellow eyes were statistically not significant. Two animals developed postoperative complications and were excluded from follow-up. CONCLUSIONS: Results imply that the implantation of the IPI is feasible in rabbit eyes with significant favorable effects on the IOP, AO and OR.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc15030954
- 003
- CZ-PrNML
- 005
- 20151021152707.0
- 007
- ta
- 008
- 151001s2014 xr ad f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.14712/18059694.2015.80 $2 doi
- 035 __
- $a (PubMed)25938898
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Detorakis, Efstathios T. $u Department of Ophthalmology, University Hospital of Heraklion, Greece; Institute of Vision & Optics, University of Crete, Greece
- 245 10
- $a Intra-scleral parathalamus implant: efficacy and safety in rabbit eyes / $c E. T. Detorakis, K. Loggaki, N. Karyotakis, H. Ginis
- 520 9_
- $a PURPOSE: A variety of anti-glaucomatous shunt designs have been proposed so far. This study evaluates the feasibility of a novel shunt design, the intra-scleral parathalamus implant (IPI), in a rabbit eye model. METHODS: Ten healthy albino rabbits were included. Measurements of the IOP, using TonoPenXL, as well as ocular rigidity (OR) and aqueous outflow facility (AO), using a previously described methodology, were performed in both eyes of each animal. Subsequently, the IPI was implanted at the left eye of all animals whereas the right eye served as control. Measurements of IOP were repeated at weekly intervals for 2 months postoperatively whereas measurements of OR and AO were repeated at the 1st and 2nd postoperative week. RESULTS: The IOP decreased significantly whereas the AO increased significantly postoperatively at the operated eyes. A significant postoperative decrease in OR was also recorded at the operated eyes. Respective differences at the fellow eyes were statistically not significant. Two animals developed postoperative complications and were excluded from follow-up. CONCLUSIONS: Results imply that the implantation of the IPI is feasible in rabbit eyes with significant favorable effects on the IOP, AO and OR.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a glaukom $x chirurgie $7 D005901
- 650 _2
- $a nitrooční tlak $7 D007429
- 650 12
- $a protézy a implantáty $7 D019736
- 650 _2
- $a králíci $7 D011817
- 650 _2
- $a sklerostomie $x metody $7 D012599
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Loggaki, Konstantina $u Institute of Vision & Optics, University of Crete, Greece
- 700 1_
- $a Karyotakis, Nikolaos $u Institute of Vision & Optics, University of Crete, Greece
- 700 1_
- $a Ginis, Harilaos $u Institute of Vision & Optics, University of Crete, Greece
- 773 0_
- $w MED00010947 $t Acta medica (Hradec Králové) Universitas Carolina, Facultas Medica Hradec Králové $x 1211-4286 $g Roč. 57, č. 4 (2014), s. 151-156
- 856 41
- $u https://actamedica.lfhk.cuni.cz/media/pdf/am_2014057040151.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 3077 $c 1072 $y 4 $z 0
- 990 __
- $a 20151001 $b ABA008
- 991 __
- $a 20151019134544 $b ABA008
- 999 __
- $a ok $b bmc $g 1094789 $s 914070
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2014 $b 57 $c 4 $d 151-156 $i 1211-4286 $m Acta Medica $n Acta Med. (Hradec Král.) $x MED00010947
- LZP __
- $b NLK118 $a Pubmed-20151001